China Custom Ie1 Y2 0.75kw to 315kw Three Phase AC Induction Electric Motor Price with Great quality

Product Description

IE1 Y2 0.75kw to 315kw Three Phase AC Induction Electric Motor Price

 

Product Description

 

Detailed Photos

 

 

Installation Instructions

 

 

Product Parameters

 

PERFORMANCE DATA
Type Output (KW)   Full Load Noise dB(A) Vibration(mm/s) LRT BDT LRA
HP Current (A) Speed (r/min) Eff. (%) P.F.(COS∅) RLT RLT RLA
Synchronous Speed 3000r/min(2P)
ZB2-63M1-2 0.18 0.25 0.64  2800 52.8  0.81  61 1.8 2.4 2.4 6.0 
ZB2-63M2-2 0.25 0.35 0.81  2800 58.2  0.81  61 1.8 2.4 2.4 6.0 
ZB2-71M1-2 0.37 0.5 1.09  2800 63.9  0.81  64 1.8 2.4 2.4 6.7 
ZB2-71M2-2 0.55 0.75 1.48  2800 69.0  0.82  64 1.8 2.4 2.5 6.7 
ZB2-80M1-2 0.75 1 1.90  2825 72.1  0.83  67 1.8 2.4 2.5 6.7 
ZB2-80M2-2 1.1 1.5 2.65  2825 75.0  0.84  67 1.8 2.4 2.5 7.7 
ZB2-90S-2 1.5 2 3.51  2840 77.2  0.84  72 1.8 2.4 2.5 7.7 
ZB2-90L-2 2.2 3 4.93  2840 79.7  0.85  72 1.8 2.4 2.5 7.7 
ZB2-100L-2 3 4 6.4  2880 81.5  0.87  76 1.8 2.4 2.5 8.3 
ZB2-112M-2 4 5.5 8.3  2890 83.1  0.88  77 1.8 2.4 2.5 8.3 
ZB2-132S1-2 5.5 7.5 11.2  2900 84.7  0.88  80 1.8 2.4 2.5 8.3 
ZB2-132S2-2 7.5 10 15.1  2900 86.0  0.88  80 1.8 2.4 2.5 8.3 
ZB2-160M1-2 11 15 21.4  2930 87.6  0.89  86 2.8 2.4 2.5 8.3 
ZB2-160M2-2 15 20 28.9  2930 88.7  0.89  86 2.8 2.4 2.5 8.3 
ZB2-160L-2 18.5 25 35.0  2930 89.3  0.90  86 2.8 2.4 2.5 8.3 
ZB2-180M-2 22 30 41.3  2940 89.9  0.90  89 2.8 2.2 2.5 8.3 
ZB2-200L1-2 30 40 55.8  2950 90.7  0.90  92 2.8 2.2 2.5 8.3 
ZB2-200L2-2 37 50 68.5  2950 91.2  0.90  92 2.8 2.2 2.5 8.3 
ZB2-225M-2 45 60 82.8  2970 91.7  0.90  92 2.8 2.2 2.5 8.3 
ZB2-250M-2 55 75 101  2970 92.1  0.90  93 3.5 2.2 2.5 8.3 
ZB2-280S-2 75 100 137  2970 92.7  0.90  94 3.5 2.2 2.5 8.3 
ZB2-280M-2 90 125 162  2970 93.0  0.91  94 3.5 2.2 2.5 8.3 
ZB2-315S-2 110 150 197  2980 93.3  0.91  96 3.5 2.0  2.4 7.8 
ZB2-315M-2 132 180 236  2980 93.5  0.91  96 3.5 2.0  2.4 7.8 
ZB2-315L1-2 160 220 282  2980 93.8  0.92  99 3.5 2.0  2.4 7.8 
ZB2-315L2-2 200 270 351  2980 94.0  0.92  99 3.5 2.0  2.4 7.8 
ZB2-355M1-2 220 300 387  2980 94.0  0.92  103 3.5 2.0  2.4 7.8 
ZB2-355M2-2 250 340 439  2980 94.0  0.92  103 3.5 1.8  2.4 7.8 
ZB2-355L1-2 280 380 492  2980 94.0  0.92  103 3.5 1.8  2.4 7.8 
ZB2-355L2-2 315 430 553  2980 94.0  0.92  103 3.5 1.8  2.4 7.8 
                       
                       
PERFORMANCE DATA
Type Output (KW)   Full Load Noise dB(A) Vibration(mm/s) LRT BDT LRA
HP Current (A) Speed (r/min) Eff. (%) P.F.(COS∅) RLT RLT RLA
 Synchronous Speed 1500r/min(4P)
ZB2-63M1-4 0.12 0.18 0.51  1400 50.0  0.72  52 1.8 2.3 2.4 4.8 
ZB2-63M2-4 0.18 0.25 0.66  1400 57.0  0.73  52 1.8 2.3 2.4 4.8 
ZB2-71M1-4 0.25 0.35 0.83  1400 61.5  0.74  55 1.8 2.3 2.4 5.7 
ZB2-71M2-4 0.37 0.5 1.14  1400 66.0  0.75  55 1.8 2.3 2.4 5.7 
ZB2-80M1-4 0.55 0.75 1.59  1390 70.0  0.75  58 1.8 2.5 2.5 5.7 
ZB2-80M2-4 0.75 1 2.08  1390 72.1  0.76  58 1.8 2.5 2.5 6.6 
ZB2-90S-4 1.1 1.5 2.89  1400 75.0  0.77  61 1.8 2.5 2.5 6.6 
ZB2-90L-4 1.5 2 3.74  1400 77.2  0.79  61 1.8 2.5 2.5 6.6 
ZB2-100L1-4 2.2 3 5.2  1420 79.7  0.81  64 1.8 2.5 2.5 7.7 
ZB2-100L2-4 3 4 6.8  1420 81.5  0.82  64 1.8 2.5 2.5 7.7 
ZB2-112M-4 4 5.5 8.9  1440 83.1  0.82  65 1.8 2.5 2.5 7.7 
ZB2-132S-4 5.5 7.5 11.9  1440 84.7  0.83  71 1.8 2.5 2.5 7.7 
ZB2-132M-4 7.5 10 15.8  1440 86.0  0.84  71 1.8 2.5 2.5 7.7 
ZB2-160M-4 11 15 22.7  1460 87.6  0.84  75 2.8 2.4 2.5 7.7 
ZB2-160L-4 15 20 30.2  1460 88.7  0.85  75 2.8 2.4 2.5 8.3 
ZB2-180M-4 18.5 25 36.6  1470 89.3  0.86  76 2.8 2.4 2.5 8.3 
ZB2-180L-4 22 30 43.2  1470 89.9  0.86  76 2.8 2.4 2.5 8.3 
ZB2-200L-4 30 40 58.4  1480 90.7  0.86  79 2.8 2.4 2.5 7.9 
ZB2-225S-4 37 50 70.9  1480 91.2  0.87  91 2.8 2.4 2.5 7.9 
ZB2-225M-4 45 60 86  1480 91.7  0.87  91 2.8 2.4 2.5 7.9 
ZB2-250M-4 55 75 104  1480 92.1  0.87  83 3.5 2.4 2.5 7.9 
ZB2-280S-4 75 100 141  1480 92.7  0.87  86 3.5 2.4 2.5 7.9 
ZB2-280M-4 90 125 169  1485 93.0  0.87  86 3.5 2.4  2.5 7.9 
ZB2-315S-4 110 150 204  1485 93.3  0.88  93 3.5 2.3  2.4 7.6 
ZB2-315M-4 132 180 244  1485 93.5  0.88  93 3.5 2.3  2.4 7.6 
ZB2-315L1-4 160 220 291  1485 93.8  0.89  97 3.5 2.3  2.4 7.6 
ZB2-315L2-4 200 270 363  1485 94.0  0.89  97 3.5 2.3  2.4 7.6 
ZB2-355M1-4 220 300 400  1490 94.0  0.89  101 3.5 2.3  2.4 7.6 
ZB2-355M2-4 250 340 449  1490 94.0  0.90  101 3.5 2.3  2.4 7.6 
ZB2-355L1-4 280 380 503  1490 94.0  0.90  101 3.5 2.3  2.4 7.6 
ZB2-355L2-4 315 430 565.73  1490 94.0  0.90  101 3.5 2.3 2.4 7.6 
                       
                       
PERFORMANCE DATA
Type Output (KW)   Full Load Noise dB(A) Vibration(mm/s) LRT BDT LRA
HP Current (A) Speed (r/min) Eff. (%) P.F.(COS∅) RLT RLT RLA
Synchronous Speed 1000r/min(6P)
ZB2-71M1-6 0.18 0.25 0.91  900 45.5  0.66  52 1.8 2.1 2.2 4.4 
ZB2-71M2-6 0.25 0.35 1.07  900 52.1  0.68  52 1.8 2.1 2.2 4.4 
ZB2-80M1-6 0.37 0.5 1.35  900 59.7  0.70  54 1.8 2.1 2.2 5.2 
ZB2-80M2-6 0.55 0.75 1.76  900 65.8  0.72  54 1.8 2.1 2.3 5.2 
ZB2-90S-6 0.75 1 2.26  910 70.0  0.72  57 1.8 2.2 2.3 6.0 
ZB2-90L-6 1.1 1.5 3.14  910 72.9  0.73  57 1.8 2.2 2.3 6.0 
ZB2-100L-6 1.5 2 4.04  940 75.2  0.75  61 1.8 2.2 2.3 6.0 
ZB2-112M-6 2.2 3 5.66  940 77.7  0.76  65 1.8 2.2 2.3 7.2 
ZB2-132S-6 3 4 7.5  960 79.7  0.76  69 1.8 2.2 2.3 7.2 
ZB2-132M1-6 4 5.5 9.8  960 81.4  0.76  69 1.8 2.2 2.3 7.2 
ZB2-132M2-6 5.5 7.5 13.1  960 83.1  0.77  69 1.8 2.2 2.3 7.2 
ZB2-160M-6 7.5 10 17.5  970 84.7  0.77  73 2.8 2.2 2.3 7.2 
ZB2-160L-6 11 15 24.8  970 86.4  0.78  73 2.8 2.2 2.3 7.2 
ZB2-180L-6 15 20 32.1  970 87.7  0.81  73 2.8 2.2 2.3 7.7 
ZB2-200L1-6 18.5 25 39.2  970 88.6  0.81  76 2.8 2.2 2.3 7.7 
ZB2-200L2-6 22 30 45.1  970 89.2  0.83  76 2.8 2.2 2.3 7.7 
ZB2-225M-6 30 40 60.9  980 90.2  0.83  76 2.8 2.2 2.3 7.7 
ZB2-250M-6 37 50 73.7  980 90.8  0.84  78 3.5 2.2 2.3 7.7 
ZB2-280S-6 45 60 87.0  980 91.4  0.86  80 3.5 2.2 2.2 7.7 
ZB2-280M-6 55 75 106  980 91.9  0.86  80 3.5 2.2 2.2 7.7 
ZB2-315S-6 75 100 143  980 92.6  0.86  85 3.5 2.2 2.2 7.7 
ZB2-315M-6 90 125 171  935 92.9  0.86  85 3.5 2.2 2.2 7.7 
ZB2-315L1-6 110 150 208  935 93.3  0.86  85 3.5 2.2  2.2 7.4 
ZB2-315L2-6 132 180 247  935 93.5  0.87  85 3.5 2.2  2.2 7.4 
ZB2-355M1-6 160 220 295  990 93.8  0.88  92 3.5 2.1  2.2 7.4 
ZB2-355M2-6 200 270 367  990 94.0  0.88  92 3.5 2.1  2.2 7.4 
ZB2-355L1-6 220 300 404  990 94.0  0.88  92 3.5 2.1  2.2 7.4 
ZB2-355L2-6 250 340 459  990 94.0  0.88  92 3.5 2.1  2.2 7.4 
                       
                       
PERFORMANCE DATA
Type Output (KW)   Full Load Noise dB(A) Vibration(mm/s) LRT BDT LRA
HP Current (A) Speed (r/min) Eff. (%) P.F.(COS∅) RLT RLT RLA
Synchronous Speed 750r/min(8P)
ZB2-80M1-8 0.18 0.25 1.18  900 38.0  0.61  52 1.8 2 2.1 3.6 
ZB2-80M2-8 0.25 0.35 1.43  690 43.4  0.61  52 1.8 2 2.1 3.6 
ZB2-90S-8 0.37 0.5 1.85  690 49.7  0.61  56 1.8 2 2.1 4.4 
ZB2-90L-8 0.55 0.75 2.44  690 56.1  0.61  56 1.8 2 2.2 4.4 
ZB2-100L1-8 0.75 1 2.78  700 61.2  0.67  59 1.8 2 2.2 4.4 
ZB2-100L2-8 1.1 1.5 3.64  700 66.5  0.69  59 1.8 2 2.2 5.5 
ZB2-112M-8 1.5 2 4.71  700 70.2  0.69  61 1.8 2 2.2 5.5 
ZB2-132S-8 2.2 3 6.34  710 74.2  0.71  64 1.8 2 2.2 6.6 
ZB2-132M-8 3 4 8.1  710 77.0  0.73  64 1.8 2 2.2 6.6 
ZB2-160M1-8 4 5.5 10.5  720 79.2  0.73  68 2.8 2 2.2 6.6 
ZB2-160M2-8 5.5 7.5 13.9  720 81.4  0.74  68 2.8 2.2 2.2 6.6 
ZB2-160L-8 7.5 10 18.3  720 83.1  0.75  68 2.8 2.2 2.2 6.6 
ZB2-180L-8 11 15 25.9  730 85.0  0.76  70 2.8 2.2 2.2 7.3 
ZB2-200L-8 15 20 34.8  730 86.2  0.76  73 2.8 2.2 2.2 7.3 
ZB2-225S-8 18.5 25 42.6  730 86.9  0.76  73 2.8 2.1 2.2 7.3 
ZB2-225M-8 22 30 49.0  730 87.4  0.78  73 2.8 2.1 2.2 7.3 
ZB2-250M-8 30 40 65.3  730 88.3  0.79  75 3.5 2.1 2.2 7.3 
ZB2-280S-8 37 50 80.1  730 88.8  0.79  76 3.5 2.1 2.2 7.3 
ZB2-280M-8 45 60 97.0  740 89.2  0.79  76 3.5 2.1 2.2 7.3 
ZB2-315S-8 55 75 115  740 89.7  0.81  82 3.5 2 2.2 7.3 
ZB2-315M-8 75 100 156  740 90.3  0.81  82 3.5 2 2.2 7.3 
ZB2-315L1-8 90 125 184  740 90.7  0.82  82 3.5 2 2.2 7.3 
ZB2-315L2-8 110 150 224  740 91.1  0.82  82 3.5 2.0  2.2 7.0 
ZB2-355M1-8 132 180 267  740 91.5  0.82  90 3.5 2.0  2.2 7.0 
ZB2-355M2-8 160 220 323  740 91.9  0.82  90 3.5 2.0  2.2 7.0 
ZB2-355L1-8 185 250 371  740 92.3  0.82  90 3.5 2.0  2.2 7.0 
ZB2-355L2-8 200 270 396  740 92.5  0.83  90 3.5 2.0  2.2 7.0 
                       
                       
PERFORMANCE DATA
Type Output (KW)   Full Load Noise dB(A) Vibration(mm/s) LRT BDT LRA
HP Current (A) Speed (r/min) Eff. (%) P.F.(COS∅) RLT RLT RLA
Synchronous Speed 600r/min(10P)
ZB2-315S-10 45 60 99.63  590 91.5  0.75  82 3.5 1.7 2.2 6.8 
ZB2-315M-10 55 75 121.11  590 92.0  0.75  82 3.5 1.7 2.2 6.8 
ZB2-315L1-10 75 100 162.10  590 92.5  0.76  82 3.5 1.7 2.2 6.8 
ZB2-315L2-10 90 125 190.96  590 93.0  0.77  82 3.5 1.7 2.2 6.8 
ZB2-355M1-10 110 150 229.91  590 93.2  0.78  90 3.5 1.7 2.2 6.6 
ZB2-355M2-10 132 180 275.00  590 93.5  0.78  90 3.5 1.5 2.2 6.6 
ZB2-355L1-10 160 220 333.34  590 93.5  0.78  90 3.5 1.5 2.2 6.6 
ZB2-355L2-10 185 250 385.42  590 93.5  0.78  90 3.5 1.5 2.2 6.6 

 

 

 

 

FAQ

Q: Are you trading company or manufacturer?
A: We are manufacturer.

Q: What is the payment terms?
A: 30% T/T in advance, 70% before shipment or L/C at sight. 

Q: What is your delivery time?
A: standard product 20 days after receiving your L/C or T/T deposit.

Q: What is the MOQ of this item?
A: 1 units for small/medium size motors, unlimited for large ones.

Q: How long is your warranty?
A: 12 months after receiving B/L.

Q: Can we used our own brand on motors ?
A: Yes, OEM and ODM also to be provided. /* January 22, 2571 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

Application: Industrial
Speed: Constant Speed
Number of Stator: Three-Phase
Function: Driving
Casing Protection: Protection Type
Number of Poles: 4
Customization:
Available

|

induction motor

How do variable frequency drives (VFDs) impact the performance of AC motors?

Variable frequency drives (VFDs) have a significant impact on the performance of AC motors. A VFD, also known as a variable speed drive or adjustable frequency drive, is an electronic device that controls the speed and torque of an AC motor by varying the frequency and voltage of the power supplied to the motor. Let’s explore how VFDs impact AC motor performance:

  • Speed Control: One of the primary benefits of using VFDs is the ability to control the speed of AC motors. By adjusting the frequency and voltage supplied to the motor, VFDs enable precise speed control over a wide range. This speed control capability allows for more efficient operation of the motor, as it can be operated at the optimal speed for the specific application. It also enables variable speed operation, where the motor speed can be adjusted based on the load requirements, resulting in energy savings and enhanced process control.
  • Energy Efficiency: VFDs contribute to improved energy efficiency of AC motors. By controlling the motor speed based on the load demand, VFDs eliminate the energy wastage that occurs when motors run at full speed even when the load is light. The ability to match the motor speed to the required load reduces energy consumption and results in significant energy savings. In applications where the load varies widely, such as HVAC systems, pumps, and fans, VFDs can provide substantial energy efficiency improvements.
  • Soft Start and Stop: VFDs offer soft start and stop capabilities for AC motors. Instead of abruptly starting or stopping the motor, which can cause mechanical stress and electrical disturbances, VFDs gradually ramp up or down the motor speed. This soft start and stop feature reduces mechanical wear and tear, extends the motor’s lifespan, and minimizes voltage dips or spikes in the electrical system. It also eliminates the need for additional mechanical devices, such as motor starters or brakes, improving overall system reliability and performance.
  • Precision Control and Process Optimization: VFDs enable precise control over AC motor performance, allowing for optimized process control in various applications. The ability to adjust motor speed and torque with high accuracy enables fine-tuning of system parameters, such as flow rates, pressure, or temperature. This precision control enhances overall system performance, improves product quality, and can result in energy savings by eliminating inefficiencies or overcompensation.
  • Motor Protection and Diagnostic Capabilities: VFDs provide advanced motor protection features and diagnostic capabilities. They can monitor motor operating conditions, such as temperature, current, and voltage, and detect abnormalities or faults in real-time. VFDs can then respond by adjusting motor parameters, issuing alerts, or triggering shutdowns to protect the motor from damage. These protection and diagnostic features help prevent motor failures, reduce downtime, and enable predictive maintenance, resulting in improved motor reliability and performance.
  • Harmonics and Power Quality: VFDs can introduce harmonics into the electrical system due to the switching nature of their operation. Harmonics are undesirable voltage and current distortions that can impact power quality and cause issues in the electrical distribution network. However, modern VFDs often include built-in harmonic mitigation measures, such as line reactors or harmonic filters, to minimize harmonics and ensure compliance with power quality standards.

In summary, VFDs have a profound impact on the performance of AC motors. They enable speed control, enhance energy efficiency, provide soft start and stop capabilities, enable precision control and process optimization, offer motor protection and diagnostic features, and address power quality considerations. The use of VFDs in AC motor applications can lead to improved system performance, energy savings, increased reliability, and enhanced control over various industrial and commercial processes.

induction motor

Where can individuals or businesses find reliable information on selecting, installing, and maintaining AC motors?

When seeking information on selecting, installing, and maintaining AC motors, individuals and businesses can refer to various reliable sources. These sources provide valuable guidance, recommendations, and best practices related to AC motors. Here are some places where one can find reliable information:

  • Manufacturer’s Documentation: AC motor manufacturers often provide detailed documentation, including product catalogs, technical specifications, installation guides, and maintenance manuals. These documents offer specific information about their motors, such as performance characteristics, electrical requirements, mounting instructions, and recommended maintenance procedures. Manufacturers’ websites are a common source for accessing these resources.
  • Industry Associations: Industry associations related to electrical engineering, motor manufacturing, or specific applications (e.g., HVAC, pumps, or industrial machinery) can be excellent resources for reliable information. These associations often publish technical articles, guidelines, and standards that cover a wide range of topics, including motor selection, installation practices, efficiency standards, and maintenance recommendations. Examples of such associations include the National Electrical Manufacturers Association (NEMA), the Institute of Electrical and Electronics Engineers (IEEE), and the Air Conditioning, Heating, and Refrigeration Institute (AHRI).
  • Professional Electricians and Engineers: Consulting with professional electricians or electrical engineers who specialize in motor applications can provide valuable insights. These professionals possess practical knowledge and experience in selecting, installing, and maintaining AC motors. They can offer personalized advice based on specific project requirements and industry best practices.
  • Energy Efficiency Programs and Agencies: Energy efficiency programs and agencies, such as government departments, utility companies, or environmental organizations, often provide resources and guidance on energy-efficient motor selection and operation. These programs may offer information on motor efficiency standards, rebate programs for high-efficiency motors, and energy-saving practices. Examples include the U.S. Department of Energy (DOE) and its Energy Star program.
  • Online Technical Forums and Communities: Online forums and communities focused on electrical engineering, motor applications, or specific industries can be valuable sources of information. Participating in these forums allows individuals and businesses to interact with experts, discuss motor-related topics, and seek advice from professionals and enthusiasts who have firsthand experience with AC motors.
  • Books and Publications: Books and technical publications dedicated to electrical engineering, motor technology, or specific applications can provide comprehensive information on AC motors. These resources cover topics ranging from motor theory and design principles to practical installation techniques and maintenance procedures. Libraries, bookstores, and online retailers offer a wide selection of relevant publications.

When accessing information from these sources, it is important to ensure that the information is up-to-date, reliable, and relevant to the specific application or requirements. Consulting multiple sources and cross-referencing information can help verify accuracy and establish a well-rounded understanding of AC motor selection, installation, and maintenance.

induction motor

What are the main components of an AC motor, and how do they contribute to its operation?

An AC motor consists of several key components that work together to facilitate its operation. These components include:

  1. Stator: The stator is the stationary part of an AC motor. It is typically made of a laminated core that provides a path for the magnetic flux. The stator contains stator windings, which are coils of wire wound around the stator core. The stator windings are connected to an AC power source and produce a rotating magnetic field when energized. The rotating magnetic field is a crucial element in generating the torque required for the motor’s operation.
  2. Rotor: The rotor is the rotating part of an AC motor. It is located inside the stator and is connected to a shaft. The rotor can have different designs depending on the type of AC motor. In an induction motor, the rotor does not have electrical connections. Instead, it contains conductive bars or coils that are short-circuited. The rotating magnetic field of the stator induces currents in the short-circuited rotor conductors, creating a magnetic field that interacts with the stator field and generates torque, causing the rotor to rotate. In a synchronous motor, the rotor contains electromagnets that are magnetized by direct current, allowing the rotor to lock onto the rotating magnetic field of the stator and rotate at the same speed.
  3. Bearing: Bearings are used to support and facilitate the smooth rotation of the rotor shaft. They reduce friction and allow the rotor to rotate freely within the motor. Bearings are typically located at both ends of the motor shaft and are designed to withstand the axial and radial forces generated during operation.
  4. End Bells: The end bells, also known as end covers or end brackets, enclose the motor’s stator and rotor assembly. They provide mechanical support and protection for the internal components of the motor. End bells are typically made of metal and are designed to provide a housing for the bearings and secure the motor to its mounting structure.
  5. Fan or Cooling System: AC motors often generate heat during operation. To prevent overheating and ensure proper functioning, AC motors are equipped with fans or cooling systems. These help dissipate heat by circulating air or directing airflow over the motor’s components, including the stator and rotor windings. Effective cooling is crucial for maintaining the motor’s efficiency and extending its lifespan.
  6. Terminal Box or Connection Box: The terminal box is a housing located on the outside of the motor that provides access to the motor’s electrical connections. It contains terminals or connection points where external wires can be connected to supply power to the motor. The terminal box ensures a safe and secure connection of the motor to the electrical system.
  7. Additional Components: Depending on the specific design and application, AC motors may include additional components such as capacitors, centrifugal switches, brushes (in certain types of AC motors), and other control devices. These components are used for various purposes, such as improving motor performance, providing starting assistance, or enabling specific control features.

Each of these components plays a crucial role in the operation of an AC motor. The stator and rotor are the primary components responsible for generating the rotating magnetic field and converting electrical energy into mechanical motion. The bearings ensure smooth rotation of the rotor shaft, while the end bells provide structural support and protection. The fan or cooling system helps maintain optimal operating temperatures, and the terminal box allows for proper electrical connections. Additional components are incorporated as necessary to enhance motor performance and enable specific functionalities.

China Custom Ie1 Y2 0.75kw to 315kw Three Phase AC Induction Electric Motor Price   with Great quality China Custom Ie1 Y2 0.75kw to 315kw Three Phase AC Induction Electric Motor Price   with Great quality
editor by CX 2024-04-08