製品説明
Recommend view more >>
|
Model Number: |
CBB65 air conditioner capacitor |
|
|
Type |
Polypropylene film capacitor |
|
|
Safety approvals: |
CQC/VDE/TUV/CL |
|
|
Approval standard |
GB/T3667,EN65712 |
|
|
Climatic category |
25/70/21,25/85/21,40/70/21,40/85/21 |
|
|
Rated voltage |
150VAC~600VAC(50-60Hz) |
|
|
Capacitance range |
3uf~100uf |
|
|
Capacitance tolerance |
+_5%(J),+_10%(K),+10%(U),-5%(U) |
|
|
Testing voltage |
|
|
|
Between terminals |
2*Un(VAC)/5s |
|
|
Between terminals and case |
2*Un+1000(VAC)/5s(>=2000VAC) |
|
|
Insulation Resistance(20) |
|
|
|
Between terminals |
>=2000MΩ,UF(500VDC,5s) |
|
|
Tangent of loss angle(20) |
<=0.002(100Hz) |
|
|
Class of safety protection |
S0/S3 |
|
|
Fault Currency |
10,000AFC(UL810) |
|
|
Place of CHINAMFG |
CHINA |
|
|
Packing |
More pieces in 1 inner box or polybag as customer request. |
|
|
Color |
accept customization |
|
|
Supplier type |
OEM factory |
|
|
Capacitance(uf) |
250/300VAC |
|
|
400-450VAC |
|
|
||||
|
|
Cylindrical |
|
Ocal |
Cylindrical |
|
Ocal |
||||
|
|
D |
H |
L*W*H |
H |
D |
L*W*H |
||||
|
10uf |
40 |
55 |
51.5*31.5*65 |
30 |
60 |
51.5*31.5*65 |
||||
|
15uf |
40 |
55 |
51.5*31.5*65 |
35 |
60 |
/ |
||||
|
20uf |
40 |
65 |
51.5*31.5*65 |
40 |
60 |
51.5*31.5*75 |
||||
|
25uf |
40 |
65 |
51.5*31.5*65 |
40 |
60 |
51.5*31.5*85 |
||||
|
30uf |
/ |
/ |
/ |
40 |
70 |
71.5*45*75 |
||||
|
35uf |
40 |
75 |
71.5*45*75 |
45 |
70 |
/ |
||||
|
40uf |
/ |
/ |
/ |
45 |
70 |
71.5*45*85 |
||||
|
45uf |
45 |
75 |
71.5*45*75 |
45 |
80 |
/ |
||||
|
50uf |
45 |
85 |
71.5*45*85 |
45 |
90 |
71.5*45*100 |
||||
|
60uf |
45 |
95 |
71.5*45*100 |
50 |
90 |
/ |
||||
What’s a dual run AC capacitor ?
* A capacitor is an electric component that temporarily stores an electrical charge and AC capacitor is a key component to start
air conditioner motors.
* A dual run capacitor supports “TWO” electric motors, 1 section for the condenser fan motor and the other for the compressor
motor. Beacause of technological innovation, the dual run capacitor can saves space by combining 2 capacitors into 1 case.
* Round cylinder-shaped dual run capacitors are commonly used for air conditioning, it can help in the starting of the compressor
and the condenser fan motor.
* Air conditioner capacitor is small in size, lightweight, heat resisting and anti-explosion.
Dual capacitors come in a variety of sizes, depending on the capacitance (µF or MFD) and the voltage.
1. The capacitance (µF or MFD) must be the same or stay within ±6% of its original value. Example: 45 µF cap can be substituted
by 42.3 to 47.7 µF with the same or better voltage ratings capacitor .
2. A 440 volt capacitor can be used in place of a 370 volt capacitor, as it can work better, but the 370 volt capacitor can’t be
used in place of a 440 volt capacitor.It will work for a while or will fail prematurely, because exceeding the capacitor’s
rated voltage will cause the dielectric to break down and the capacitor to short out.
“TIME” to Replace
The Dual Run AC Capacitor needs to be replaced when the following conditions occur:
1. The fan wouldn’t spin – the condenser fan motor maybe died.
2. The air conditioner is making humming sound, but no air flow.
3. Air conditioner stopped cooling – the compressor in the condenser maybe not coming on.
“SUPER EASY” to Install
* First, Shut off power to the A/C at both the thermostat and the breaker box. Secondly, taking out the capacitor.
* What’s important, make sure you know which wire is for which terminal – 3 terminals on the top are labeled “Herm”/”H” for
the compressor motor, “Fan”/”F” for the fan and “C” for the common line.
* Direct replacement, no need to change wiring or adapter.
* Last but not least, self-install will save you a substantial amount of money!
What is a starting capacitor and a running capacitor for a motor?
As we all know, a single-phase AC motor is not like a three-phase motor. It can turn when it is powered. It needs a starting torque to rotate, and the clockwise and anti-clockwise of this torque determines the steering of the motor, and there are many
ways to start. Among them, the capacitor start is one, which is customarily called the start capacitor, and the single-phase motor needs it to rotate smoothly.
However, some single-phase motors have more than 1 capacitor, and some motors have 2 capacitors. Why? Because some motors are equipped with a starting capacitor and a running capacitor, what is going on?
The difference between start capacitors and run capacitors.
Running capacitor: It is connected to the secondary winding to form an alternating magnetic field after phase-shifting the alternating current, and forms an approximately circular elliptical rotating magnetic field with the alternating magnetic field of the main winding. So he can be the same capacitor, but its role is different.
No matter what kind of capacitor, it has a starting effect at the beginning of the motor. However, when the motor reaches about 75% of the rated speed, the starting capacitor is automatically disconnected by the centrifugal switch, and the running capacitor continues to work with the motor. The process of starting the motor is actually the process of “column phase”. Because a single-phase motor is different from a three-phase motor, there is no phase difference, and a rotating magnetic field cannot be generated. The function of the capacitor is to make the starting winding current of the motor lead the running winding by 90 electrical angles in time and space to form a phase difference. Among them, the running capacitor also plays the role of balancing the current between the main and auxiliary windings. Since the starting capacitor works for an instant and a short time, the withstand voltage is required to be above 250V, while the running capacitor needs to work for a long time, and the withstand voltage is required to be above 450V.
The starting capacitor is to make the starting coil of the single-phase motor energized at the time of starting, and then cut off after starting. The running capacitor is to make the motor perform capacitance compensation during the operation, so the starting capacitor cannot be less, and the running capacitor can not be used.
The running capacitor is the starting capacitor used when the press is working normally. When the press starts, it starts the press together with the running capacitor. After the press is turned up, the start capacitor is disconnected. The running and starting capacitors are together, but 1 of the starting capacitors is open, and the starting capacitor is useless when the motor turns. What is the difference between the starting capacitor and the running capacitor? That is the capacity of the starting capacitor is large, generally 2-5 times that of the running capacitor, while the capacity of the running capacitor is small, and the capacity difference between the 2 is huge and easy to distinguish.
/* 2571 年 1 月 22 日 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
| 応用: | 家 |
|---|---|
| Certification: | ISO9001, CE, CCC, RoHS |
| Type: | Polypropylene Film Capacitor |
| サンプル: |
US$ 0.01/Piece
1個(最小注文数) | サンプルを注文する |
|---|
| カスタマイズ: |
利用可能
|
|
|---|
.shipping-cost-tm .tm-status-off{背景: なし;パディング: 0;色: #1470cc}
|
送料:
単位あたりの推定運賃。 |
送料と配達予定時間について。 |
|---|
| 支払方法: |
|
|---|---|
|
初期支払い 全額支払い |
| 通貨: | US$ |
|---|
| 返品と返金: | 商品到着後30日以内に返金を申請することができます。 |
|---|

AC モーターは HVAC (暖房、換気、空調) システムでどのような役割を果たしますか?
HVAC(暖房、換気、空調)システムにおいて、ACモーターは様々なコンポーネントや機能において重要な役割を果たしています。これらのモーターは、ファン、コンプレッサー、ポンプ、その他HVACシステム内の重要な機器に電力を供給します。HVACシステムにおけるACモーターの具体的な役割を見ていきましょう。
- 空調ユニット(AHU)と換気システム: ACモーターは、空調設備(AHU)や換気システムのファンを駆動します。これらのファンは新鮮な空気を取り込み、建物内の空気を循環させ、古い空気を排出します。モーターは、ダクトを通して空気を循環させ、空間全体に均等に分配するために必要な動力を提供します。適切な室内空気質の維持、湿度のコントロール、そして十分な換気の確保に重要な役割を果たします。
- チラーと冷却塔: 冷却にチラーを使用するHVACシステムは、コンプレッサーを駆動するためにACモーターを使用しています。モーターはコンプレッサーを駆動し、冷媒をシステム全体に循環させ、室内環境から熱を吸収して屋外に放出します。ACモーターは冷却塔にも使用され、水を蒸発させることでチラーシステムの熱を放散します。モーターはファンを駆動し、冷却塔に空気を送り込み、熱伝達を促進します。
- ヒートポンプ: ACモーターは、暖房と冷房の両方を提供するヒートポンプシステムに不可欠なコンポーネントです。モーターはヒートポンプ内のコンプレッサーを駆動し、室内と屋外の間の熱移動を可能にします。冷房モードでは、モーターは冷媒を循環させて室内の熱を抽出し、屋外に放出します。暖房モードでは、モーターは冷媒の流れを逆転させて屋外の空気または地面から熱を抽出し、室内に放出します。
- 炉とボイラー: 暖房システムでは、ACモーターが炉やボイラーの送風機やファンに動力を供給します。モーターは送風機を駆動し、暖められた空気や蒸気を建物全体に送り出します。これにより、快適な室内温度が維持され、空間内の効率的な熱分配が確保されます。
- ポンプと循環システム: HVACシステムには、水暖房や冷水システムなど、水循環用のポンプが組み込まれていることがよくあります。ACモーターはこれらのポンプを駆動し、システム内で水やその他の熱伝達流体を循環させるために必要な圧力を供給します。モーターは効率的な流量を確保し、熱エネルギーの効率的な伝達に貢献します。
- ダンパーとアクチュエーター: ACモーターは、HVACシステムにおいて、空気の流れを制御し、ダンパーやアクチュエータの位置を調整するために使用されます。これらのモーターは、空気流量の調整、温度制御、そしてゾーンごとの空調制御を可能にします。モーターの速度や位置を調整することで、HVACシステムは建物内の様々なエリアの空気の分布と温度を正確に制御することができます。
HVACシステムのACモーターは、可変速制御、エネルギー効率、変動負荷下での信頼性の高い動作など、特定の性能要件を満たすように設計されています。これらのモーターのメンテナンスと定期的な点検は、HVACシステムの最適な性能、エネルギー効率、そして長寿命を確保する上で不可欠です。
結論として、ACモーターはファン、コンプレッサー、ポンプ、アクチュエーターに電力を供給することで、HVACシステムにおいて重要な役割を果たしています。適切な空気循環、温度制御、効率的な熱伝達を可能にし、建物全体の快適性、空気質、そしてエネルギー効率の向上に貢献します。

現代の AC モーターには省エネ技術や機能が備わっていますか?
はい、現代のACモーターには、効率を向上させ消費電力を削減するための様々な省エネ技術や機能が組み込まれていることがよくあります。これらの進歩は、エネルギー損失を最小限に抑え、モーターの性能を最適化することを目的としています。現代のACモーターに一般的に搭載されている省エネ技術と機能をいくつかご紹介します。
- 高効率設計: 現代のACモーターは、旧モデルに比べて高い効率基準で設計されていることが多いです。これらのモーターは、先進的な材料と最適化された設計を用いて製造されており、モーター巻線の抵抗損失や摩擦・抗力による機械損失などのエネルギー損失を低減しています。高効率モーターは、入力電力のより高い割合を有用な機械的仕事に変換することで、エネルギーを節約できます。
- プレミアム効率基準: NEMA Premium®やIE(国際効率)などの国際規格や規制では、ACモーターの最低エネルギー効率要件が定められています。プレミアム効率モーターはこれらの基準を満たすか上回り、標準モーターと比較して効率が向上しています。これらのモーターでは、より高い効率レベルを実現するために、コア材料の改良、巻線抵抗の低減、換気システムの最適化といった設計上の改良がしばしば採用されています。
- 可変周波数ドライブ(VFD): VFD(可変速駆動装置)は、モーターに供給される電力の周波数と電圧を調整することで、ACモーターを可変速で動作させる制御装置です。モーターの速度を負荷要件に合わせて調整することで、VFDはエネルギー消費を大幅に削減できます。VFDは、HVACシステム、ポンプ、ファンなど、モーターが長時間にわたって部分負荷で動作するアプリケーションで特に効果的です。
- 効率的なモーター制御アルゴリズム: モーター駆動装置や制御システムに実装された最新のモーター制御アルゴリズムは、モーターの動作を最適化し、エネルギー効率を向上させます。これらのアルゴリズムは、負荷条件に基づいて電圧、周波数、電流などのモーターパラメータを動的に調整することで、エネルギーの無駄を最小限に抑えます。センサレスベクトル制御やベクトル制御(FOC)などの高度な制御技術は、モーターの磁界を精密に制御することで、モーターの性能と効率を向上させます。
- 冷却と換気の改善: 効果的な冷却と換気は、モーターの効率維持に不可欠です。最新のACモーターは、ファン設計の改良、気流管理の改善、換気経路の最適化など、強化された冷却システムを備えていることが多くなっています。効率的な冷却は、モーターの過熱を防ぎ、放熱による損失を低減します。一部のモーターには、過度の温度上昇を回避し、最適な動作状態を確保するための熱監視および保護機構も組み込まれています。
- ベアリングと摩擦低減: ACモーターでは、ベアリングや機械部品における摩擦損失が大きなエネルギー消費につながる可能性があります。現代のモーターでは、シールベアリングや無潤滑ベアリングといった高度なベアリング技術を採用することで、摩擦を低減し、エネルギー損失を最小限に抑えています。さらに、ローターとステーターの設計の最適化、そして製造技術の向上により、機械損失の低減とモーター効率の向上が実現しています。
- 力率改善: 力率は、電力がどれだけ効率的に利用されているかを示す指標です。力率の低いACモーターは、無効電力消費量の増加につながり、電力システム全体の効率を低下させる可能性があります。コンデンサバンクや力率補正コントローラなどの力率補正技術は、力率を改善し、無効電力損失を最小限に抑え、モーターの運転効率を向上させるためによく用いられます。
これらの省エネ技術と機能を導入することで、最新のACモーターはエネルギー効率を大幅に向上させ、消費電力と運用コストを削減できます。ACモーターの使用を検討する際には、認められた効率基準を満たすかそれを超えるモデルを選択し、メーカーまたは専門家に相談して、特定の用途や省エネ要件との適合性を確認することをお勧めします。

AC モーターとは何ですか? DC モーターとどう違うのですか?
ACモーター(交流モーターとも呼ばれる)は、交流電流で動作する電気モーターの一種です。磁場の相互作用を通じて電気エネルギーを機械エネルギーに変換します。ACモーターは、家電製品から産業機械まで、様々な用途で広く使用されています。ACモーターとは何か、そしてDCモーターとの違いについて詳しく説明します。
ACモーター:
ACモーターは、ステータとローターという2つの主要部品で構成されています。ステータはモーターの固定部分であり、ステータ巻線が内蔵されています。これらの巻線は通常銅線で作られ、交流電流を流すと回転磁界を発生させるように特定の配置で配置されています。一方、ローターはモーターの回転部分であり、通常は導体バーまたはコイルを備えた積層鋼鉄コアで作られています。ローター巻線はシャフトに接続されており、ステータによって生成された回転磁界との相互作用によってローターが回転します。
ACモーターの動作は電磁誘導の原理に基づいています。ステータ巻線にAC電源が供給されると、変化する磁界がローター巻線に電圧を誘導し、さらに磁界が発生します。ステータの回転磁界とローターの磁界の相互作用によってトルクが発生し、ローターが回転します。回転速度はAC電源の周波数とモーターの極数に依存します。
DCモーター:
DCモーター(直流モーターとも呼ばれる)は、直流電流で動作します。トルクを生成するために磁場の相互作用を利用するACモーターとは異なり、DCモーターは整流の原理を利用して回転運動を生み出します。DCモーターは、ACモーターと同様に、ステータとローターで構成されています。ステータにはステータ巻線が巻かれており、ローターはコイルまたは永久磁石を備えた回転アーマチュアで構成されています。
DCモーターでは、ステーター巻線に直流電流を流すと磁界が発生します。ローターは、ブラシと整流子、または電子整流子のいずれかを用いて磁界に整流され、回転を開始します。ローター巻線を流れる電流の方向は連続的に反転し、回転が継続されます。DCモーターの速度は、モーターに印加する電圧を調整するか、電子速度制御方式を用いることで制御できます。
違い:
AC モーターと DC モーターの主な違いは次のとおりです。
- 電源: ACモーターは交流で動作します。交流は、ほとんどの住宅や商業ビルの標準的な電源です。一方、DCモーターは直流を必要とするため、通常は交流を直流に変換する電源が必要です。
- 工事: ACモーターとDCモーターは、ステーターとローターの構造は似ていますが、巻線の設計と配置が異なります。ACモーターは一般的に三相巻線を備えていますが、DCモーターは電機子巻線または永久磁石のいずれかを備えています。
- スピードコントロール: ACモーターは通常、電源周波数と極数によって決まる固定速度で動作します。一方、DCモーターは速度制御の柔軟性が高く、幅広い速度範囲で簡単に調整できます。
- 効率: ACモーターは一般的にDCモーターよりも効率が高いです。ACモーターはより高い電力密度を実現できるため、高出力アプリケーションに適している場合が多いです。一方、DCモーターは速度制御に優れており、精密な速度制御が求められるアプリケーションでよく使用されます。
- 用途: ACモーターは、産業機械、HVACシステム、ポンプ、コンプレッサーなどの用途で広く使用されています。DCモーターは、ロボット工学、電気自動車、コンピューターディスクドライブ、小型家電製品などに使用されています。
結論として、ACモーターとDCモーターは、電源、構造、速度制御、効率、そして用途において異なります。ACモーターは磁場の相互作用を利用して交流で動作しますが、DCモーターは整流を利用して直流で動作します。それぞれのモーターには利点があり、電力要件、速度制御の必要性、効率性などの要素に基づいて、異なる用途に適しています。


editor by CX 2024-04-26