MODEL |
INPUT VOLTAGE |
RATED POWER (kW) |
RATED INPUT CURRENT (UN) |
RATED OUTPUT CURRENT (UN) |
|
FU9000D-0R7G-S2 |
1PH 220V-240V |
0.75 |
8.2 |
4 |
|
FU9000D-1R5G-S2 |
|
1.5 |
14 |
7 |
|
FU9000D-2R2G-S2 |
|
2.2 |
23 |
9.6 |
|
FU9000D-0R7G-2 |
3PH 220V-240V |
0.75 |
4.5 |
4 |
|
FU9000D-1R5G-2 |
|
1.5 |
8 |
7 |
|
FU9000D-2R2G-2 |
|
2.2 |
11 |
10 |
|
FU9000D-004G-2 |
|
4 |
14.6 |
13 |
|
FU9000D-5R5G-2 |
|
5.5 |
26 |
25 |
|
FU9000D-7R5G-2 |
|
7.5 |
35 |
32 |
|
FU9000D-011G-2 |
|
11 |
46.5 |
45 |
|
FU9000D-015G-2 |
|
15 |
62 |
60 |
|
FU9000D-018G-2 |
|
18.5 |
76 |
75 |
|
FU9000D-571G-2 |
|
22 |
92 |
91 |
|
FU9000D-030G-2 |
|
30 |
113 |
112 |
|
FU9000D-037G-2 |
|
37 |
157 |
150 |
|
FU9000D-045G-2 |
|
45 |
180 |
176 |
|
FU9000D-055G-2 |
|
55 |
214 |
210 |
|
FU9000D-075G-2 |
|
75 |
307 |
304 |
|
FU9000D-0R7G-4 |
3PH 380V-480V |
0.75 |
3.4 |
2.5 |
|
FU9000D-1R5G-4 |
|
1.5 |
5 |
3.7 |
|
FU9000D-2R2G-4 |
|
2.2 |
5.8 |
5 |
|
FU9000D-004G-4 |
|
4.0 |
10.5 |
9 |
|
FU9000D-5R5G-4 |
|
5.5 |
14.6 |
13 |
|
FU9000D-7R5G-4 |
|
7.5 |
20.5 |
17 |
|
FU9000D-011G-4 |
|
11 |
26 |
25 |
|
FU9000D-015G-4 |
|
15 |
35 |
32 |
|
FU9000D-018G-4 |
|
18.5 |
38.5 |
37 |
|
FU9000D-571G-4 |
|
22 |
46.5 |
45 |
|
FU9000D-030G-4 |
|
30 |
62 |
60 |
|
FU9000D-037G-4 |
|
37 |
76 |
75 |
|
FU9000D-045G-4 |
|
45 |
92 |
91 |
|
FU9000D-055G-4 |
|
55 |
113 |
112 |
|
FU9000D-075G-4 |
|
75 |
157 |
150 |
|
FU9000D-090G-4 |
|
90 |
180 |
176 |
|
FU9000D-110G-4 |
|
110 |
214 |
210 |
|
FU9000D-132G-4 |
|
132 |
256 |
253 |
|
FU9000D-160G-4 |
|
160 |
307 |
304 |
|
FU9000D-185G-4 |
|
185 |
340 |
330 |
|
FU9000D-200G-4 |
|
200 |
385 |
377 |
|
FU9000D-220G-4 |
|
220 |
430 |
426 |
|
FU9000D-250G-4 |
|
250 |
468 |
465 |
|
FU9000D-280G-4 |
|
280 |
525 |
520 |
|
FU9000D-315G-4 |
|
315 |
590 |
585 |
|
FU9000D-350G-4 |
|
350 |
665 |
650 |
|
FU9000D-400G-4 |
|
400 |
785 |
725 |
|
FU9000D-500G-4 |
|
500 |
883 |
820 |
|
FU9000D-630G-4 |
|
630 |
1080 |
1000 |
Customer Feedback
Domande frequenti
Q 1: What’s the function of USFULL VFD?
A: USFULL VFD control the speed and frequency of motors, which is widely used in industrial control, automation system and pump system.
Q 2: How to choose suitable VFD for my machine?
A: Please send us your machine details, we will provide you most suitable model type.
Q 3: What’s the payment term?
A: We accept T/T, L/C, D/A, D/P, WESTERN UNION, PAYPAL, CASH, etc.
Q 4: How you control quality?
A: Our inverters strictly follow ISO9001 quality control system. After 4 times quality inspect and high temperature testing we will print “QA” pass.
Q 5: What kind of certificate you have?
A: We have ISO, CE, CB, TUV, etc.
Send Inquiry
/* 22 gennaio 2571 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
| Applicazione: | Three Phase Transducer, Industry |
|---|---|
| Output Type: | Triple |
| Principle of Work: | Vector Control Transducer |
| Switch Mode: | PWM Control |
| Main Circuit Type: | Voltaggio |
| Voltage of Power Supply: | Low Voltage Variable-Frequency Drive |
| Campioni: |
US$ 250/Piece
1 pezzo (ordine minimo) | |
|---|
| Personalizzazione: |
Disponibile
|
|
|---|

Puoi spiegare il concetto di efficienza del motore e come si collega ai motori a corrente alternata?
L'efficienza del motore è una misura dell'efficacia con cui un motore elettrico converte l'energia elettrica in energia meccanica. Rappresenta il rapporto tra la potenza utile in uscita del motore (potenza meccanica) e la potenza in ingresso (potenza elettrica) che consuma. Un'efficienza più elevata indica che il motore converte una percentuale maggiore di energia elettrica in lavoro meccanico utile, riducendo al minimo le perdite di energia sotto forma di calore e altre inefficienze.
Nel caso dei motori a corrente alternata, l'efficienza è particolarmente importante a causa del loro ampio utilizzo in diverse applicazioni, che spaziano dagli elettrodomestici ai macchinari industriali. I motori a corrente alternata possono essere sia motori a induzione, che sono i più comuni, sia motori sincroni, che funzionano a velocità costante sincronizzata con la frequenza di alimentazione.
L'efficienza di un motore a corrente alternata è influenzata da diversi fattori:
- Progettazione del motore: La progettazione del motore, inclusi i materiali del nucleo, la configurazione degli avvolgimenti e la costruzione del rotore, ne influenzano l'efficienza. I motori progettati con avvolgimenti a bassa resistenza, materiali magnetici di alta qualità e rotori ottimizzati tendono ad avere un'efficienza maggiore.
- Dimensioni del motore: Anche le dimensioni fisiche del motore possono influire sulla sua efficienza. I motori più grandi hanno generalmente un'efficienza maggiore perché possono dissipare il calore in modo più efficace, riducendo le perdite. Tuttavia, è importante selezionare una dimensione del motore che corrisponda ai requisiti dell'applicazione per evitare di far funzionare il motore a bassa efficienza a causa di sottocarico.
- Condizioni operative: Le condizioni operative, come la richiesta di carico, la velocità e la temperatura, possono influenzare l'efficienza del motore. I motori sono in genere progettati per la massima efficienza al carico nominale o in prossimità di esso. Il funzionamento del motore oltre il carico nominale o con carichi molto leggeri può ridurne l'efficienza. Inoltre, temperature ambiente elevate possono causare maggiori perdite e una riduzione dell'efficienza.
- Perdite magnetiche: I motori a corrente alternata subiscono perdite dovute a effetti magnetici, come isteresi e correnti parassite nei materiali del nucleo. Queste perdite provocano la generazione di calore e riducono l'efficienza complessiva. Progettare motori che riducano al minimo le perdite magnetiche attraverso l'uso di materiali magnetici di alta qualità e un nucleo ottimizzato può migliorare l'efficienza.
- Perdite di attrito meccanico e di vento: Anche le perdite per attrito e per effetto del vento nei cuscinetti, nell'albero e nelle parti rotanti del motore contribuiscono alle perdite di energia e alla riduzione dell'efficienza. Una corretta lubrificazione, la scelta dei cuscinetti e la riduzione della resistenza meccanica non necessaria possono contribuire a ridurre al minimo queste perdite.
L'efficienza è un fattore importante da considerare nella scelta di un motore a corrente alternata, poiché influisce direttamente sul consumo energetico e sui costi operativi. I motori con maggiore efficienza consumano meno energia elettrica, con conseguente riduzione delle bollette energetiche e dell'impatto ambientale. Inoltre, una maggiore efficienza si traduce spesso in una minore generazione di calore, il che può migliorare l'affidabilità e la durata del motore.
Gli enti di regolamentazione e gli organismi di standardizzazione, come la Commissione Elettrotecnica Internazionale (IEC) e la National Electrical Manufacturers Association (NEMA), forniscono classi di efficienza e standard per i motori a corrente alternata, come le classi di efficienza IE e gli standard di efficienza premium NEMA. Questi standard aiutano i consumatori a confrontare i livelli di efficienza di diversi motori e a fare scelte consapevoli per ottimizzare l'efficienza energetica.
In sintesi, l'efficienza del motore è una misura dell'efficacia con cui un motore a corrente alternata converte l'energia elettrica in energia meccanica. Scegliendo motori con maggiore efficienza, gli utenti possono ridurre il consumo energetico, i costi operativi e l'impatto ambientale, garantendo al contempo prestazioni affidabili e sostenibili.

What are the common signs of AC motor failure, and how can they be addressed?
AC motor failure can lead to disruptions in various industrial and commercial applications. Recognizing the common signs of motor failure is crucial for timely intervention and preventing further damage. Here are some typical signs of AC motor failure and potential ways to address them:
- Excessive Heat: Excessive heat is a common indicator of motor failure. If a motor feels excessively hot to the touch or emits a burning smell, it could signify issues such as overloaded windings, poor ventilation, or bearing problems. To address this, first, ensure that the motor is properly sized for the application. Check for obstructions around the motor that may be impeding airflow and causing overheating. Clean or replace dirty or clogged ventilation systems. If the issue persists, consult a qualified technician to inspect the motor windings and bearings and make any necessary repairs or replacements.
- Abnormal Noise or Vibration: Unusual noises or vibrations coming from an AC motor can indicate various problems. Excessive noise may be caused by loose or damaged components, misaligned shafts, or worn bearings. Excessive vibration can result from imbalanced rotors, misalignment, or worn-out motor parts. Addressing these issues involves inspecting and adjusting motor components, ensuring proper alignment, and replacing damaged or worn-out parts. Regular maintenance, including lubrication of bearings, can help prevent excessive noise and vibration and extend the motor’s lifespan.
- Intermittent Operation: Intermittent motor operation, where the motor starts and stops unexpectedly or fails to start consistently, can be a sign of motor failure. This can be caused by issues such as faulty wiring connections, damaged or worn motor brushes, or problems with the motor’s control circuitry. Check for loose or damaged wiring connections and make any necessary repairs. Inspect and replace worn or damaged motor brushes. If the motor still exhibits intermittent operation, it may require professional troubleshooting and repair by a qualified technician.
- Overheating or Tripping of Circuit Breakers: If an AC motor consistently causes circuit breakers to trip or if it repeatedly overheats, it indicates a problem that needs attention. Possible causes include high starting currents, excessive loads, or insulation breakdown. Verify that the motor is not overloaded and that the load is within the motor’s rated capacity. Check the motor’s insulation resistance to ensure it is within acceptable limits. If these measures do not resolve the issue, consult a professional to assess the motor and its electrical connections for any faults or insulation breakdown that may require repair or replacement.
- Decreased Performance or Efficiency: A decline in motor performance or efficiency can be an indication of impending failure. This may manifest as reduced speed, decreased torque, increased energy consumption, or inadequate power output. Factors contributing to decreased performance can include worn bearings, damaged windings, or deteriorated insulation. Regular maintenance, including lubrication and cleaning, can help prevent these issues. If performance continues to decline, consult a qualified technician to inspect the motor and perform any necessary repairs or replacements.
- Inoperative Motor: If an AC motor fails to operate entirely, there may be an issue with the power supply, control circuitry, or internal motor components. Check the power supply and connections for any faults or interruptions. Inspect control circuitry, such as motor starters or contactors, for any damage or malfunction. If no external faults are found, it may be necessary to dismantle the motor and inspect internal components, such as windings or brushes, for any faults or failures that require repair or replacement.
It’s important to note that motor failure causes can vary depending on factors such as motor type, operating conditions, and maintenance practices. Regular motor maintenance, including inspections, lubrication, and cleaning, is essential for early detection of potential failure signs and for addressing issues promptly. When in doubt, it is advisable to consult a qualified electrician, motor technician, or manufacturer’s guidelines for appropriate troubleshooting and repair procedures specific to the motor model and application.

Come funziona il meccanismo di controllo della velocità nei motori a corrente alternata?
Il meccanismo di controllo della velocità nei motori a corrente alternata varia a seconda del tipo di motore. Qui analizzeremo i metodi di controllo della velocità utilizzati in due tipologie comuni di motori a corrente alternata: motori a induzione e motori sincroni.
Controllo della velocità nei motori a induzione:
I motori a induzione sono generalmente progettati per funzionare a una velocità costante, determinata dalla frequenza della rete elettrica e dal numero di poli del motore. Tuttavia, esistono diversi metodi per controllare la velocità dei motori a induzione:
- Variazione della frequenza: Variando la frequenza dell'alimentazione CA, è possibile regolare la velocità di un motore a induzione. Questo metodo è noto come controllo tramite azionamento a frequenza variabile (VFD). I VFD convertono l'alimentazione CA in ingresso in un'uscita a frequenza e tensione variabili, consentendo un controllo preciso della velocità del motore. Questo metodo è comunemente utilizzato in applicazioni industriali in cui il controllo della velocità è fondamentale, come nastri trasportatori, pompe e ventilatori.
- Modifica del numero di poli dello statore: La velocità di un motore a induzione è inversamente proporzionale al numero di poli dello statore. Modificando le connessioni degli avvolgimenti dello statore o utilizzando un motore con una diversa configurazione dei poli, è possibile regolare la velocità. Tuttavia, questo metodo è meno comunemente utilizzato e viene tipicamente impiegato in applicazioni specializzate.
- Aggiunta di resistenza esterna: In alcuni casi, è possibile aggiungere una resistenza esterna al circuito del rotore di un motore a induzione per controllarne la velocità. Questo metodo, noto come controllo della resistenza del rotore, prevede l'inserimento di resistori in serie agli avvolgimenti del rotore. Variando la resistenza, è possibile regolare la corrente e la coppia del rotore, ottenendo così il controllo della velocità. Tuttavia, questo metodo è meno efficiente e viene utilizzato principalmente in applicazioni specifiche in cui non è richiesto un controllo preciso.
Controllo della velocità nei motori sincroni:
I motori sincroni offrono un controllo della velocità più preciso rispetto ai motori a induzione grazie al loro funzionamento sincrono intrinseco. I seguenti metodi sono comunemente utilizzati per il controllo della velocità nei motori sincroni:
- Regolazione della frequenza di alimentazione CA: Analogamente ai motori a induzione, la variazione della frequenza di alimentazione CA può controllare la velocità dei motori sincroni. Regolando la frequenza di rete, è possibile modificare la velocità sincrona del motore. Questo metodo è spesso utilizzato in applicazioni in cui è richiesto un controllo preciso della velocità, come macchinari e processi industriali.
- Utilizzo di un azionamento a frequenza variabile: Gli azionamenti a frequenza variabile (VFD) possono essere utilizzati anche per controllare la velocità dei motori sincroni. Convertendo la corrente alternata in ingresso in un'uscita a frequenza e tensione variabili, i VFD possono regolare la velocità del motore con elevata precisione ed efficienza.
- Controllo del campo DC: In alcuni motori sincroni, il campo magnetico del rotore è fornito da una sorgente di corrente continua (CC), consentendo un controllo preciso della velocità del motore. Regolando la corrente del campo CC, è possibile controllare l'intensità del campo magnetico e la velocità del motore. Questo metodo è comunemente utilizzato in applicazioni che richiedono un controllo di velocità preciso, come processi industriali e macchinari ad alte prestazioni.
Questi metodi offrono diverse modalità per controllare la velocità dei motori a corrente alternata, consentendo flessibilità e adattabilità a diverse applicazioni. La scelta del meccanismo di controllo della velocità dipende da fattori quali il tipo di motore, l'intervallo di velocità desiderato, i requisiti di precisione, le considerazioni di efficienza e i vincoli di costo.


editor by CX 2024-05-03