Product Description

Product Description

 Y series motors are totally enclosed fan cooled(TEFC).squirrel cage three-phase induction motors,developed with new technique They are renewal and upgrading products of Y-series The mounting dimension is fully comformed with IEC standard. The motors have the merits of beautiful modeling ,compact structure ,low noise,high efficiency,large staring torque,easy serving,etc The motors are adopted with F class insulation and designed with assessing method for insulation practice,it enhances greatly motor’s safety and reliability.These motors have reached an international advandced level  Y series motors can be widely used in various machines and equipments,such as drilling machines ,blower ,pumps,compressors,transporters, agricultural and food processing machines.

Ambient Temperature

-15ºC≤0≤40ºC

Altitude

Not exceeding 1000 meters

Rated Voltage

380V±5%

Protection Type

IP44/IP54

Connection

Y Start-Connection for 3 Kw and below

Y Date-Connection for 3 Kw or more

Cooling Type 

IC0141

Insulation Class

Class B/Class F

Rated Frequency

50Hz/60Hz

Duty/Rating

Continuous(S1) Or customized 

The terminal box IP55

If you need more information, please contact us.

 

Product Parameters

Model Rated power Current Rotating speed Efficiency Power factor Stall torque
Rated torque
Stall current
Rated current
Maximum torque
Rated torque
Type (KW) (A) (r/min) (η%) (cosΦ) Ts
TN
Ist
TN
Tmax
TN
YD801- 4 0.45 1.4 1420 66 0.74 1.5 6.5 1.8
2 0.55 1.5 2860 65 0.85 1.6 7 1.8
YD802- 4 0.55 1.7 1420 68 0.74 1.5 6.5 1.8
2 0.75 2.0  2860 66 0.85 1.6 7 1.8
YD90S- 4 0.85 2.3 1430 74 0.77 1.5 6.5 1.8
2 1.1 2.8 2850 72 0.84 1.6 7 1.8
YD90L- 4 1.3 3.3 1430 76 0.78 1.5 6.5 1.8
2 1.8 4.3 2850 74 0.84 1.6 7 1.8
YD100L1- 4 2 4.8 1430 78 0.81 1.5 6.5 1.8
2 2.4 5.6 2850 76 0.86 1.6 7 1.8
YD100L2- 4 2.4 5.6 1430 79 0.83 1.5 6.5 1.8
2 3.0  6.7 2850 77 0.89 1.6 7 1.8
YD112M- 4 3.3 7.4 1450 81 0.83 1.5 6.5 1.8
2 4.0  8.6 2860 80 0.88 1.6 7 1.8
YD132S- 4 4.5 9.8 1450 83 0.84 1.5 6.5 1.8
2 5.5 11.9 2860 79 0.88 1.6 7 1.8
YD132M- 4 6.5 13.8 1450 84 0.85 1.5 6.5 1.8
2 8 17.1 2880 80 0.89 1.6 7 1.8
YD160M- 4 9 18.5 1460 87 0.85 1.5 6.5 1.8
2 11 22.9 2920 82 0.89 1.6 7 1.8
YD160L- 4 11 22.3 1460 87 0.86 1.5 6.5 1.8
2 14 28.8 2920 82 0.90  1.6 7 1.8
YD180M- 4 15 29.4 1470 89 0.87 1.5 6.5 1.8
2 18.5 36.7 2940 85 0.90  1.6 7 1.8
YD180L- 4 18.5 35.9 1470 89 0.88 1.5 6.5 1.8
2 22 42.7 2940 86 0.91 1.5 7 1.8
YD200L- 4 26 49.9 1470 89 0.89 1.4 6.5 1.8
2 30 58.3 2950 85 0.92 1.4 7 1.8
YD225S- 4 32 60.7 1480 90 0.89 1.4 6.5 1.8
2 37 71.7 2960 86 0.92 1.4 7 1.8
YD225M- 4 37 69.4 1480 91 0.89 1.4 6.5 1.8
2 45 86.4 2960 87 0.92 1.4 7 1.8
YD250M- 4 45 84.4 1480 91 0.89 1.4 6.5 1.8
2 55 103.2 2960 88 0.92 1.4 7 1.8
YD280S- 4 60 111.3 1480 91 0.90  1.4 6.5 1.8
2 72 135.1 2970 88 0.92 1.4 7 1.8
YD280M- 5 72 133.6 1480 91 0.90  1.4 6.5 1.8
2 82 152.2 2970 88 0.93 1.4 7 1.8
YD90S- 6 0.65 2.2 920 64 0.70  1.4 6 1.8
4 0.85 2.3 1420 70 0.79 1.3 6.5 1.8
YD90L- 6 0.85 2.8 930 66 0.70  1.4 6 1.8
4 1.1 3.0  1420 71 0.79 1.3 6.5 1.8
YD100L1- 6 1.3 3.8 940 71 0.70  1.4 6 1.8
4 1.8 4.4 1440 77 0.80  1.3 6.5 1.8
YD100L2- 6 1.5 4.3 940 75 0.70  1.4 6 1.8
4 2.2 5.4 1440 77 0.80  1.4 6.5 1.8
YD112M- 6 2.2 5.7 960 77 0.75 1.4 6 1.8
4 2.8 6.7 1440 77 0.82 1.3 6.5 1.8
                   

Model Rated power Current Rotating speed Efficiency Power factor Stall torque
Rated torque
Stall current
Rated current
Maximum torque
Rated torque
Type (KW) (A) (r/min) (η%) (cosΦ) Ts
TN
Ist
TN
Tmax
TN
YD132S- 6 3 7.7 960 79 0.75 1.4 6 1.8
4 4 9.5 1440 80 0.82 1.3 6.5 1.8
YD132M- 6 4 9.8 960 81 0.76 1.4 6 1.8
4 5.5 12.3 1440 80 0.85 1.3 6.5 1.8
YD160M- 6 6.5 15.1 970 84 0.78 1.4 6 1.8
4 8 17.4 1460 83 0.85 1.3 6.5 1.8
YD160L- 6 9 20.6 970 85 0.78 1.4 6 1.8
4 11 23.4 1460 84 0.85 1.3 6.5 1.8
YD180M- 6 11 25.9 980 85 0.78 1.4 6 1.8
4 14 29.8 1470 85 0.85 1.3 6.5 1.8
YD180L- 6 13 29.4 980 86 0.78 1.4 6 1.8
4 16 33.6 1470 85 0.85 1.3 6.5 1.8
YD200L- 6 18.5 41.4 980 87 0.78 1.4 6.5 1.8
4 22 44.7 1460 87 0.86 1.3 7 1.8
YD225- 6 22 44.2 980 88 0.86 1.4 6.5 1.8
4 28 56.2 1470 87 0.87 1.3 7 1.8
YD224M- 6 26 52.2 980 88 0.86 1.4 6.5 1.8
4 34 66.0  1470 87 0.90  1.3 7 1.8
YD250M- 6 32 62.1 980 90 0.87 1.4 6.5 1.8
4 42 74.7 1470 88 0.91 1.3 7 1.8
YD280S- 6 42 81.5 980 90 0.87 1.4 6.5 1.8
4 55 104.2 1470 89 0.90  1.3 7 1.8
YD280M- 6 55 106.7 990 90 0.87 1.4 6.5 1.8
4 72 138.1 1480 89 0.89 1.3 7 1.8
YD90L- 6 0.45 1.9 680 58 0.63 1.5 5.5 1.8
4 0.75 1.92 1420 72 0.87 1.5 6.5 1.8
YD110L- 8 0.85 3.1 700 68 0.63 1.5 5.5 1.8
4 1.5 3.5 1420 75 0.88 1.5 6.5 1.8
YD112M- 8 1.5 5.0  700 72 0.63 1.5 5.5 1.8
4 2.4 5.3 1420 78 0.88 1.5 6.5 1.8
YD132S- 8 2.2 7.0  720 75 0.64 1.5 5.5 1.8
4 3.3 7.1 1440 80 0.88 1.5 6.5 1.8
YD132M- 8 3 9.0  720 78 0.66 1.5 5.5 1.8
4 4.5 9.4 1440 82 0.88 1.5 6.5 1.8
YD160M- 8 5 13.9 730 83 0.66 1.5 5.5 1.8
4 7.5 15.2 1450 84 0.89 1.5 6.5 1.8
YD160- 8 7 19.0  730 85 0.66 1.5 6 1.8
4 11 21.8 1470 86 0.89 1.5 7 1.8
YD180L- 8 11 26.0  740 86 0.74 1.5 6 1.8
4 17 31.9 1470 87 0.92 1.5 7 1.8
YD200L1- 8 14 33.0  740 86 0.74 1.5 6 1.8
4 22 41.3 1470 88 0.92 1.5 7 1.8
YD200L2- 8 17 40.1 740 87 0.74 1.5 6 1.8
4 26 48.8 1470 88 0.95 1.5 7 1.8
YD225M- 8 24 53.2 740 89 0.77 1.4 6 1.8
4 34 66.7 1470 88 0.88 1.3 7 1.8
YD250M- 8 30 64.9 740 90 0.78 1.4 6 1.8
4 42 78.8 1480 89 0.91 1.3 7 1.8

Model Rated power Current Rotating speed Efficiency Power factor Stall torque
Rated torque
Stall current
Rated current
Maximum torque
Rated torque
Type (KW) (A) (r/min) (η%) (cosΦ) Ts
TN
Ist
TN
Tmax
TN
YD132S- 6 3 7.7 960 79 0.75 1.4 6 1.8
4 4 9.5 1440 80 0.82 1.3 6.5 1.8
YD132M- 6 4 9.8 960 81 0.76 1.4 6 1.8
4 5.5 12.3 1440 80 0.85 1.3 6.5 1.8
YD160M- 6 6.5 15.1 970 84 0.78 1.4 6 1.8
4 8 17.4 1460 83 0.85 1.3 6.5 1.8
YD160L- 6 9 20.6 970 85 0.78 1.4 6 1.8
4 11 23.4 1460 84 0.85 1.3 6.5 1.8
YD180M- 6 11 25.9 980 85 0.78 1.4 6 1.8
4 14 29.8 1470 85 0.85 1.3 6.5 1.8
YD180L- 6 13 29.4 980 86 0.78 1.4 6 1.8
4 16 33.6 1470 85 0.85 1.3 6.5 1.8
YD200L 6 18.5 41.4 980 87 0.78 1.4 6.5 1.8
4 22 44.7 1460 87 0.86 1.3 7 1.8
YD225- 6 22 44.2 980 88 0.86 1.4 6.5 1.8
4 28 56.2 1470 87 0.87 1.3 7 1.8
YD224M- 6 26 52.2 980 88 0.86 1.4 6.5 1.8
4 34 66.0  1470 87 0.90  1.3 7 1.8
YD250M- 6 32 62.1 980 90 0.87 1.4 6.5 1.8
4 42 74.7 1470 88 0.91 1.3 7 1.8
YD280S- 6 42 81.5 980 90 0.87 1.4 6.5 1.8
4 55 104.2 1470 89 0.90  1.3 7 1.8
YD280M- 6 55 106.7 990 90 0.87 1.4 6.5 1.8
4 72 138.1 1480 89 0.89  1.3 7 1.8
YD90L- 6 0.45 1.9 680 58 0.63 1.5 5.5 1.8
4 0.75 1.92 1420 72 0.87 1.5 6.5 1.8
YD110L- 8 0.85 3.1 700 68 0.63 1.5 5.5 1.8
4 1.5 3.5 1420 75 0.88 1.5 6.5 1.8
YD112M- 8 1.5 5 700 72 0.63 1.5 5.5 1.8
4 2.4 5.3 1440 78 0.88 1.5 6.5 1.8
YD132S- 8 2.2 7 720 75 0.64 1.5 5.5 1.8
4 3.3 7.1 1440 80 0.88 1.5 6.5 1.8
YD132M- 8 3 9 720 78 0.66 1.5 5.5 1.8
4 4.5 9.4 1440 82 0.88 1.5 6.5 1.8
YD160M- 8 5 13.9 730 83 0.66 1.5 5.5 1.8
4 7.5 15.2 1450 84 0.89 1.5 6.5 1.8
YD160- 8 7 19 730 85 0.66 1.5 6 1.8
4 11 21.8 1450 86 0.89 1.5 7 1.8
YD180L- 8 11 26.0  730 86 0.74 1.5 6 1.8
4 17 31.9 1470 87 0.92 1.5 7 1.8
YD200L1- 8 14 33.0  740 86 0.74 1.5 6 1.8
4 22 41.3 1470 88 0.92 1.5 7 1.8
YD200L2- 8 17 40.1 740 87 0.74 1.5 6 1.8
4 26 48.8 1470 88 0.95 1.5 7 1.8
YD225M- 8 24 53.2 740 89 0.77 1.4 6 1.8
4 34 66.7 1470 88 0.88 1.3 7 1.8
YD250M- 8 30 64.9 740 90 0.78 1.4 6 1.8
4 42 78.8 1480 89 0.91 1.3 7 1.8

Model Rated power Current Rotating speed Efficiency Power factor Stall torque
Rated torque
Stall current
Rated current
Maximum torque
Rated torque
Type (KW) (A) (r/min) (η%) (cosΦ) Ts
TN
Ist
TN
Tmax
TN
YD280S- 8 40 83.5 740 91 0.80  1.4 6 1.8
4 55 102 1480 90 0.91 1.3 7 1.8
YD280M- 8 47 96.9 740 91 0.81 1.4 6 1.8
4 67 122.9 1480 90 0.92 1.3 7 1.8
YD90S- 8 0.35 1.6 680 56 0.60  1.5 5 1.8
6 0.45 1.4 930 70 0.72 1.5 6 1.8
YD90L- 8 0.45 1.9 680 59 0.60  1.5 5 1.8
6 0.65 1.9 930 71 0.73 1.5 6 1.8
YD100L- 8 0.72 2.9 710 65 0.60  1.5 5 1.8
6 1.1 3.1 950 75 0.73 1.5 6 1.8
YD112M- 7 1.3 4.5 710 72 0.61 1.5 5 1.8
6 1.8 4.8 950 78 0.73 1.5 6 1.8
YD132S- 8 1.8 5.8 730 72 0.62 1.5 5 1.8
6 2.4 6.2 970 80 0.73 1.5 6 1.8
YD132M- 8 2.6 8.2 730 78 0.62 1.5 5 1.8
6 3.7 9.4 970 82 0.73 1.5 6 1.8
YD160M- 8 4.5 13.3 730 83 0.62 1.5 5 1.8
6 6 14.7 980 85 0.73 1.5 6 1.8
YD160L- 8 6 17.5 730 84 0.62 1.5 5 1.8
6 8 19.4 980 86 0.73 1.5 6 1.8
YD180M- 8 7.5 21.9 730 84 0.62 1.5 5 1.8
6 10 24.2 980 86 0.73 1.5 6 1.8
YD180L- 8 9 24.8 730 85 0.65 1.5 5 1.8
6 12 28.3 980 86 0.75 1.5 6 1.8
YD200L1- 8 12 32.5 730 86 0.65 1.5 5 1.8
6 17 39.1 980 87 0.76 1.5 6 1.8
YD200L2- 8 15 40.3 730 87 0.65 1.5 5 1.8
6 20 45.4 980 88 0.76 1.5 6 1.8
YD250M- 8 15 33.1 730 88 0.78 1.5 5 1.8
6 30 58.5 980 90 0.86 1.5 6 1.8
YD160M- 12 2.6 11.6 480 74 0.46 1.2 4 1.8
6 5 11.9 970 84 0.76 1.4 6 1.8
YD160L- 12 3.7 16.4 480 76 0.46 1.2 4 1.8
6 7 15.8 970 85 0.79 1.4 6 1.8
YD180M- 12 5.5 19.6 490 79 0.54 1.3 4 1.8
6 10 20.5 980 86 0.86 1.5 6 1.8
YD200L1- 12 7.5 25.1 490 83 0.56 1.5 4 1.8
6 13 26.4 980 87 0.86 1.5 6 1.8
YD200L2- 12 9 28.9 490 83 0.57 1.5 4 1.8
6 15 30.4 980 87 0.87 1.5 6 1.8
YD225M- 12 12 35.8 490 85 0.61 1.5 4 1.8
6 20 39.7 980 88 0.87 1.5 6 1.8
YD250M- 12 15 42.9 490 86 0.63 1.5 4 1.8
6 24 47.6 980 89 0.87 1.5 6 1.8
YD280S- 12 20 54.8 490 88 0.63 1.5 4 1.8
6 30 58.9 990 89 0.87 1.5 6 1.8
YD280M- 12 24 63.7 490 88 0.65 1.5 4 1.8
6 37 72.6 990 89 0.87 1.5 6 1.8
YD100L- 6 0.75 2.6 950 67 0.65 1.8 5.5 1.8
4 1.3 3.7 1440 72 0.75 1.6 6 1.8
2 1.8 4.5 2900 71 0.85 1.6 7 1.8
YD112M- 6 1.1 3.5 960 73 0.65 1.7 5.5 1.8
4 2.0  5.1 1450 74 0.81 1.4 6 1.8
2 2.4 5.8 2920 75 0.85 1.6 7 1.8
YD132S- 6 1.8 5.1 970 74 0.71 1.4 5.5 1.8
4 2.6 6.1 1460 78 0.83 1.3 6 1.8
2 3 7.4 2910 71 0.87 1.7 7 1.8
YD132M1- 6 2.2 6.0  970 77 0.72 1.3 5.5 1.8
4 3.3 7.5 1460 80 0.84 1.3 6 1.8
2 4 8.8 2910 76 0.91 1.7 7 1.8
YD132M2- 6 2.6 6.9 970 80 0.72 1.3 5.5 1.8
4 4 9.0  1460 80 0.84 1.3 6 1.8
2 5 10.8 2910 77 0.91 1.7 7 1.8
YD160M- 6 3.7 9.5 980 82 0.72 1.5 5.5 1.8
4 5 11.2 1470 81 0.84 1.3 6 1.8
2 6 13.2 2930 76 0.91 1.4 7 1.8
YD160L- 6 4.5 11.4 980 83 0.72 1.5 5.5 1.8
4 7 15.1 1470 83 0.85 1.2 6 1.8
2 9 18.8 2930 79 0.92 1.3 7 1.8
YD112M- 8 0.65 2.7 700 59 0.63 1.4 4.5 1.8
6 2 5.1 1450 74 0.81 1.3 6 1.8
4 2.4 5.8 2920 74 0.85 1.2 7 1.8
YD132S- 8 1 3.6 720 69 0.61 1.4 4.5 1.8
6 2.6 6.1 1460 78 0.83 1.2 6 1.8
4 3 7.1 2910 74 0.87 1.4 7 1.8

Detailed Photos

FAQ

Q: Where is Your factory?
A: HangZhou city, ZHangZhoug Province.
 
Q: Do you accept OEM/ODM service?
A: Yes, avaliable.
 
Q: Are you trading company or manufacturer?
A: We are a manufacturer.
 
Q: What about the shipment?
A: By sea, By air and By express delivery.
 
Q: What is the delivery time?
A: It depends on the order quantity, usually 35days after confirmation.
 
Q: Can I buy different products in 1 container?
A: Yes, but no more than 5 models.
 
Q: What is the warranty time?
A: One year.

Q: Can you offer the sample?
A: Of course we can.

Application: Industrial, Universal, Household Appliances
Operating Speed: Constant Speed
Number of Stator: Three-Phase
Species: Y, Y2 Series Three-Phase
Rotor Structure: Squirrel-Cage
Casing Protection: Closed Type
Samples:
US$ 280/Piece
1 Piece(Min.Order)

|

Customization:
Available

|

induction motor

Are there specific maintenance requirements for AC motors to ensure optimal performance?

Yes, AC motors have specific maintenance requirements to ensure their optimal performance and longevity. Regular maintenance helps prevent unexpected failures, maximizes efficiency, and extends the lifespan of the motor. Here are some key maintenance practices for AC motors:

  1. Cleaning and Inspection: Regularly clean the motor to remove dust, dirt, and debris that can accumulate on the motor surfaces and hinder heat dissipation. Inspect the motor for any signs of damage, loose connections, or abnormal noise/vibration. Address any issues promptly to prevent further damage.
  2. Lubrication: Check the motor’s lubrication requirements and ensure proper lubrication of bearings, gears, and other moving parts. Insufficient or excessive lubrication can lead to increased friction, overheating, and premature wear. Follow the manufacturer’s guidelines for lubrication intervals and use the recommended lubricants.
  3. Belt and Pulley Maintenance: If the motor is coupled with a belt and pulley system, regularly inspect and adjust the tension of the belts. Improper belt tension can affect motor performance and efficiency. Replace worn-out belts and damaged pulleys as needed.
  4. Cooling System Maintenance: AC motors often have cooling systems such as fans or heat sinks to dissipate heat generated during operation. Ensure that these cooling systems are clean and functioning properly. Remove any obstructions that may impede airflow and compromise cooling efficiency.
  5. Electrical Connections: Regularly inspect the motor’s electrical connections for signs of loose or corroded terminals. Loose connections can lead to voltage drops, increased resistance, and overheating. Tighten or replace any damaged connections and ensure proper grounding.
  6. Vibration Analysis: Periodically perform vibration analysis on the motor to detect any abnormal vibrations. Excessive vibration can indicate misalignment, unbalanced rotors, or worn-out bearings. Address the underlying causes of vibration to prevent further damage and ensure smooth operation.
  7. Motor Testing: Conduct regular motor testing, such as insulation resistance testing and winding resistance measurement, to assess the motor’s electrical condition. These tests can identify insulation breakdown, winding faults, or other electrical issues that may affect motor performance and reliability.
  8. Professional Maintenance: For more complex maintenance tasks or when dealing with large industrial motors, it is advisable to involve professional technicians or motor specialists. They have the expertise and tools to perform in-depth inspections, repairs, and preventive maintenance procedures.

It’s important to note that specific maintenance requirements may vary depending on the motor type, size, and application. Always refer to the manufacturer’s guidelines and recommendations for the particular AC motor in use. By following proper maintenance practices, AC motors can operate optimally, minimize downtime, and have an extended service life.

induction motor

What are the common signs of AC motor failure, and how can they be addressed?

AC motor failure can lead to disruptions in various industrial and commercial applications. Recognizing the common signs of motor failure is crucial for timely intervention and preventing further damage. Here are some typical signs of AC motor failure and potential ways to address them:

  • Excessive Heat: Excessive heat is a common indicator of motor failure. If a motor feels excessively hot to the touch or emits a burning smell, it could signify issues such as overloaded windings, poor ventilation, or bearing problems. To address this, first, ensure that the motor is properly sized for the application. Check for obstructions around the motor that may be impeding airflow and causing overheating. Clean or replace dirty or clogged ventilation systems. If the issue persists, consult a qualified technician to inspect the motor windings and bearings and make any necessary repairs or replacements.
  • Abnormal Noise or Vibration: Unusual noises or vibrations coming from an AC motor can indicate various problems. Excessive noise may be caused by loose or damaged components, misaligned shafts, or worn bearings. Excessive vibration can result from imbalanced rotors, misalignment, or worn-out motor parts. Addressing these issues involves inspecting and adjusting motor components, ensuring proper alignment, and replacing damaged or worn-out parts. Regular maintenance, including lubrication of bearings, can help prevent excessive noise and vibration and extend the motor’s lifespan.
  • Intermittent Operation: Intermittent motor operation, where the motor starts and stops unexpectedly or fails to start consistently, can be a sign of motor failure. This can be caused by issues such as faulty wiring connections, damaged or worn motor brushes, or problems with the motor’s control circuitry. Check for loose or damaged wiring connections and make any necessary repairs. Inspect and replace worn or damaged motor brushes. If the motor still exhibits intermittent operation, it may require professional troubleshooting and repair by a qualified technician.
  • Overheating or Tripping of Circuit Breakers: If an AC motor consistently causes circuit breakers to trip or if it repeatedly overheats, it indicates a problem that needs attention. Possible causes include high starting currents, excessive loads, or insulation breakdown. Verify that the motor is not overloaded and that the load is within the motor’s rated capacity. Check the motor’s insulation resistance to ensure it is within acceptable limits. If these measures do not resolve the issue, consult a professional to assess the motor and its electrical connections for any faults or insulation breakdown that may require repair or replacement.
  • Decreased Performance or Efficiency: A decline in motor performance or efficiency can be an indication of impending failure. This may manifest as reduced speed, decreased torque, increased energy consumption, or inadequate power output. Factors contributing to decreased performance can include worn bearings, damaged windings, or deteriorated insulation. Regular maintenance, including lubrication and cleaning, can help prevent these issues. If performance continues to decline, consult a qualified technician to inspect the motor and perform any necessary repairs or replacements.
  • Inoperative Motor: If an AC motor fails to operate entirely, there may be an issue with the power supply, control circuitry, or internal motor components. Check the power supply and connections for any faults or interruptions. Inspect control circuitry, such as motor starters or contactors, for any damage or malfunction. If no external faults are found, it may be necessary to dismantle the motor and inspect internal components, such as windings or brushes, for any faults or failures that require repair or replacement.

It’s important to note that motor failure causes can vary depending on factors such as motor type, operating conditions, and maintenance practices. Regular motor maintenance, including inspections, lubrication, and cleaning, is essential for early detection of potential failure signs and for addressing issues promptly. When in doubt, it is advisable to consult a qualified electrician, motor technician, or manufacturer’s guidelines for appropriate troubleshooting and repair procedures specific to the motor model and application.

induction motor

Can you explain the basic working principle of an AC motor?

An AC motor operates based on the principles of electromagnetic induction. It converts electrical energy into mechanical energy through the interaction of magnetic fields. The basic working principle of an AC motor involves the following steps:

  1. The AC motor consists of two main components: the stator and the rotor. The stator is the stationary part of the motor and contains the stator windings. The rotor is the rotating part of the motor and is connected to a shaft.
  2. When an alternating current (AC) is supplied to the stator windings, it creates a changing magnetic field.
  3. The changing magnetic field induces a voltage in the rotor windings, which are either short-circuited conductive bars or coils.
  4. The induced voltage in the rotor windings creates a magnetic field in the rotor.
  5. The magnetic field of the rotor interacts with the rotating magnetic field of the stator, resulting in a torque force.
  6. The torque force causes the rotor to rotate, transferring mechanical energy to the connected shaft.
  7. The rotation of the rotor continues as long as the AC power supply is provided to the stator windings.

This basic working principle is applicable to various types of AC motors, including induction motors and synchronous motors. However, the specific construction and design of the motor may vary depending on the type and intended application.

China wholesaler Yd Series Motor Three Phase Multi-Speed Asynchronous Electric AC Motor Yd180m-4/6   with Great quality China wholesaler Yd Series Motor Three Phase Multi-Speed Asynchronous Electric AC Motor Yd180m-4/6   with Great quality
editor by CX 2023-12-04