China Standard Commercial Fan Motor AC Fan Motor Copper Coil Air-Conditioner Parts Fan Motor a/c vacuum pump

Product Description

Model Static Press Vol.Fre. Motor Type Output Input Current Speed Noise
Pa V/Hz W W A r/min Db(A)
FP34 12 220V/50Hz YDK10-4C 10 34 0.15 820 ≤37
30 220V/50Hz YDK12-4C 12 41 0.18 900 ≤40
50 220V/50Hz YDK18-4C 16 48 0.21 1130 ≤42
FP51 12 220V/50Hz YSK12-4C 12 48 0.19 810 ≤39
30 220V/50Hz YSK18-4C 18 56 0.25 950 ≤42
50 220V/50Hz YSK28-4C 22 68 0.3 1120 ≤44
FP68 12 220V/50Hz YSK18-4C 20 55 0.25 840 ≤41
30 220V/50Hz YSK30-4C 25 76 0.32 1030 ≤44
50 220V/50Hz YSK40-4C 40 81 0.36 1160 ≤46
FP85 12 220V/50Hz YSK32-4C 28 77 0.34 980 ≤43
30 220V/50Hz YSK34-4C 35 87 0.4 1050 ≤46
50 220V/50Hz YSK54-4C 45 95 0.43 1230 ≤47
FP102 12 220V/50Hz YSK41-4C 30 98 0.45 1040 ≤45
30 220V/50Hz YSK52-4C 40 112 0.47 1150 ≤47
50 220V/50Hz YSK65-4C 55 114 0.5 1240 ≤49
FP136 12 220V/50Hz YDK12-4C 18 140 0.64 940 ≤46
YSK41-4C 30
30 220V/50Hz YSK37-4C 37 149 0.69 1080 ≤48
YDK18-4C 20
50 220V/50Hz YDK28-4C 22 170 0.78 1240 ≤50
YSK65-4C 55
FP170 12 220V/50Hz YSK40-4C 40 162 0.78 1085 ≤48
30 220V/50Hz YSK52-4C 52 174 0.8 1150 ≤50
50 220V/50Hz YSK60-4C 60 187 0.87 1290 ≤52
FP204 12 220V/50Hz YSK42-4C 42 197 0.9 1112 ≤50
30 220V/50Hz YSK55-4C 55 228 1.04 1150 ≤52
50 220V/50Hz YSK72-4C 67 238 1.1 1280 ≤54
FP238 12 220V/50Hz YSK56-4C 55 240 1.02 1150 ≤52
30 220V/50Hz YSK67-4B4 63 251 1.18 1210 ≤54
50 220V/50Hz YSK100-4C 80 293 1.36 1320 ≤56

/* January 22, 2571 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

Application: Industrial
Speed: Constant Speed
Number of Stator: Single-Phase
Samples:
US$ 100/Piece
1 Piece(Min.Order)

|

Order Sample

Customization:
Available

|

.shipping-cost-tm .tm-status-off{background: none;padding:0;color: #1470cc}

Shipping Cost:

Estimated freight per unit.







about shipping cost and estimated delivery time.
Payment Method:







 

Initial Payment



Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.

induction motor

Can AC motors be used in both residential and commercial settings?

Yes, AC motors can be used in both residential and commercial settings. The versatility and wide range of applications of AC motors make them suitable for various environments and purposes.

In residential settings, AC motors are commonly found in household appliances such as refrigerators, air conditioners, washing machines, fans, and pumps. These motors are designed to meet the specific requirements of residential applications, providing reliable and efficient operation for everyday tasks. For example, air conditioners utilize AC motors to drive the compressor and fan, while washing machines use AC motors for agitating and spinning the drum.

In commercial settings, AC motors are extensively used in a wide range of applications across different industries. They power machinery, equipment, and systems that are crucial for commercial operations. Some common examples include:

  • Industrial machinery and manufacturing equipment: AC motors drive conveyor belts, pumps, compressors, mixers, fans, blowers, and other machinery used in manufacturing, production, and processing facilities.
  • HVAC systems: AC motors are used in commercial heating, ventilation, and air conditioning (HVAC) systems to drive fans, blowers, and pumps for air circulation, cooling, and heating.
  • Commercial refrigeration: AC motors are utilized in commercial refrigeration systems for powering compressors, condenser fans, and evaporator fans in supermarkets, restaurants, and cold storage facilities.
  • Office equipment: AC motors are present in various office equipment such as printers, photocopiers, scanners, and ventilation systems, ensuring their proper functioning.
  • Transportation: AC motors are used in electric vehicles, trams, trains, and other forms of electric transportation systems, providing the necessary propulsion.
  • Water and wastewater treatment: AC motors power pumps, mixers, and blowers in water treatment plants, wastewater treatment plants, and pumping stations.

The adaptability, efficiency, and controllability of AC motors make them suitable for a wide range of residential and commercial applications. Whether it’s powering household appliances or driving industrial machinery, AC motors play a vital role in meeting the diverse needs of both residential and commercial settings.

induction motor

What are the safety considerations when working with or around AC motors?

Working with or around AC motors requires careful attention to safety to prevent accidents, injuries, and electrical hazards. Here are some important safety considerations to keep in mind:

  • Electrical Hazards: AC motors operate on high voltage electrical systems, which pose a significant electrical hazard. It is essential to follow proper lockout/tagout procedures when working on motors to ensure that they are de-energized and cannot accidentally start up. Only qualified personnel should perform electrical work on motors, and they should use appropriate personal protective equipment (PPE), such as insulated gloves, safety glasses, and arc flash protection, to protect themselves from electrical shocks and arc flash incidents.
  • Mechanical Hazards: AC motors often drive mechanical equipment, such as pumps, fans, or conveyors, which can present mechanical hazards. When working on or near motors, it is crucial to be aware of rotating parts, belts, pulleys, or couplings that can cause entanglement or crushing injuries. Guards and safety barriers should be in place to prevent accidental contact with moving parts, and proper machine guarding principles should be followed. Lockout/tagout procedures should also be applied to the associated mechanical equipment to ensure it is safely de-energized during maintenance or repair.
  • Fire and Thermal Hazards: AC motors can generate heat during operation, and in some cases, excessive heat can pose a fire hazard. It is important to ensure that motors are adequately ventilated to dissipate heat and prevent overheating. Motor enclosures and cooling systems should be inspected regularly to ensure proper functioning. Additionally, combustible materials should be kept away from motors to reduce the risk of fire. If a motor shows signs of overheating or emits a burning smell, it should be immediately shut down and inspected by a qualified professional.
  • Proper Installation and Grounding: AC motors should be installed and grounded correctly to ensure electrical safety. Motors should be installed according to manufacturer guidelines, including proper alignment, mounting, and connection of electrical cables. Adequate grounding is essential to prevent electrical shocks and ensure the safe dissipation of fault currents. Grounding conductors, such as grounding rods or grounding straps, should be properly installed and regularly inspected to maintain their integrity.
  • Safe Handling and Lifting: AC motors can be heavy and require proper handling and lifting techniques to prevent musculoskeletal injuries. When moving or lifting motors, equipment such as cranes, hoists, or forklifts should be used, and personnel should be trained in safe lifting practices. It is important to avoid overexertion and use proper lifting tools, such as slings or lifting straps, to distribute the weight evenly and prevent strain or injury.
  • Training and Awareness: Proper training and awareness are critical for working safely with or around AC motors. Workers should receive training on electrical safety, lockout/tagout procedures, personal protective equipment usage, and safe work practices. They should be familiar with the specific hazards associated with AC motors and understand the appropriate safety precautions to take. Regular safety meetings and reminders can help reinforce safe practices and keep safety at the forefront of everyone’s minds.

It is important to note that the safety considerations mentioned above are general guidelines. Specific safety requirements may vary depending on the motor size, voltage, and the specific workplace regulations and standards in place. It is crucial to consult relevant safety codes, regulations, and industry best practices to ensure compliance and maintain a safe working environment when working with or around AC motors.

induction motor

Can you explain the basic working principle of an AC motor?

An AC motor operates based on the principles of electromagnetic induction. It converts electrical energy into mechanical energy through the interaction of magnetic fields. The basic working principle of an AC motor involves the following steps:

  1. The AC motor consists of two main components: the stator and the rotor. The stator is the stationary part of the motor and contains the stator windings. The rotor is the rotating part of the motor and is connected to a shaft.
  2. When an alternating current (AC) is supplied to the stator windings, it creates a changing magnetic field.
  3. The changing magnetic field induces a voltage in the rotor windings, which are either short-circuited conductive bars or coils.
  4. The induced voltage in the rotor windings creates a magnetic field in the rotor.
  5. The magnetic field of the rotor interacts with the rotating magnetic field of the stator, resulting in a torque force.
  6. The torque force causes the rotor to rotate, transferring mechanical energy to the connected shaft.
  7. The rotation of the rotor continues as long as the AC power supply is provided to the stator windings.

This basic working principle is applicable to various types of AC motors, including induction motors and synchronous motors. However, the specific construction and design of the motor may vary depending on the type and intended application.

China Standard Commercial Fan Motor AC Fan Motor Copper Coil Air-Conditioner Parts Fan Motor   a/c vacuum pump		China Standard Commercial Fan Motor AC Fan Motor Copper Coil Air-Conditioner Parts Fan Motor   a/c vacuum pump
editor by CX 2024-03-28