China manufacturer Y2 Ykk Yks High Voltage AC Squirrel Cage Asynchronous Induction Motor vacuum pump brakes

Product Description

Y2, YKK, YKS High Voltage AC Squirrel Cage Asynchronous Induction Motor

 

1. General introduction
YKK-series (2Kv~11Kv) squirrel-cage 3 phase asynchronous motor, is building on the advanced technology in the nation. The protection degree of the motor is of IP23(according toGb4942.1), and the cooling method is IC01(according to GB/T1993).
The motors has a lot of advantages such as height efficiency, enerty-saving, low noise and vibration ,light weight and reilable performance. THey are easy for installation andmaintenance. The motor has high insulation class and moistureproof capacity.
The motor is used to drive various mechanical equipments such as blowers, pumps, crushers, storkremoing machines and other  equipments. It can serve as the prime movers in coalmines, mechanical industries, powerplants and various industrial enterprises.

2. Brief Construction
The motor adopts compacted box structure, welding-jointed steel plate forits frame, light weight, rigid in construction, there is closed air to air coolers on the stator frame convenient for installation and maintenance.
Stator winding adopts F class insulation and its end adopts firm binding. The whole stator adopts solvent-free varnish Vacuum pressure impregnation(VPI) to ensure the stator has excellent electric property and humidity resistance.
Rotor is made of cast aluminium or copper bar. Aluminium rotor is made of pure aluminium, copper barwedging copper rotor enhances the entorety of rotor.
The motor adopts rolling bering or sliding bering, according to the output power and rotary speed. Bearing protection grade normally is IP44. If the motor’s protect grade increases, so does the berings’. Rolling bearing adopts iubricating gresse and its grease charger and discharger can be charged or discharged without stopping the motor.
The junction box is of IP54 protection grade and it is usually mounted on the motor’s right side(viewed from shaft extension end.) It is also can be mounted on the left side and its outlets have 4 optional orientations(up, down, left or right.) Separated grounding unit is available in main junction box, too.

3. Working conditions and performance
a) THe rated power supply is 6KV/50HZ, 10KV/50HZ.
b) The insulation class is F, the protection degreeis IP44 or IP54.
c) Height above sea level does not exceeding 1000 meters.
d) Height environmental temperature-15ºC.silding bering>5ºC.
e) The ambient air relative humidity does not exceed 95% and the mean monthly minimum temperature of current month does not exceed 25ºC
f) The deviation between power voltage and rated voltage is less than5%.
g) Rated frequency:50Hz+1%.
h) Duty type:continuous duty type S1.
i) Cooling method is IC611.

Order requirement:
Please indicate the motor type, rated output, rated voltage, rated frequency, synchronous speed, Explosion proof Mark, mounting type, protection grade, cooling method, rotation direction(view from the shaft extension side), using environment (indoor /outside).

Comparison of different series High Voltage motors

No. Squirrel-cage motor Y YKK YKS Y2
Slip ring motor YR YRKK YRKS /
1 Structure Box-type construction, made up of steel plates welded with each other Compact struction
2 Cooling method IC01 or (IC11, IC21, IC31) IC611 or IC616 IC81W IC411
3 Natural ventilation, with top mounted protection cover With top mounted air-air cooler With top mounted air-water cooler  
4 Protection type IP23 IP44 or IP54 IP44 or IP54 IP54
5 Insulation F
6 Mounting arrangement IMB3
7 Voltage available 3kv, 3.3kv;      6kv, 6.6kv;      10kv, 11kv
8 Frequency available 50Hz , 60Hz

Pictures of  YKK,YKS High Voltage AC Squirrel Cage Asynchronous Induction Motors

Vertical flange mounted IC81W air-water cooled high voltage squirrel cage motor

Vertical flange mounted cast iron frame IC411 TEFC high voltage squirrel cage motor

Cerificate
/* January 22, 2571 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

Application: Industrial
Operating Speed: Constant Speed
Number of Stator: Three-Phase
Species: Y, Y2 Series Three-Phase
Rotor Structure: Squirrel-Cage
Casing Protection: Closed Type
Customization:
Available

|

induction motor

How do variable frequency drives (VFDs) impact the performance of AC motors?

Variable frequency drives (VFDs) have a significant impact on the performance of AC motors. A VFD, also known as a variable speed drive or adjustable frequency drive, is an electronic device that controls the speed and torque of an AC motor by varying the frequency and voltage of the power supplied to the motor. Let’s explore how VFDs impact AC motor performance:

  • Speed Control: One of the primary benefits of using VFDs is the ability to control the speed of AC motors. By adjusting the frequency and voltage supplied to the motor, VFDs enable precise speed control over a wide range. This speed control capability allows for more efficient operation of the motor, as it can be operated at the optimal speed for the specific application. It also enables variable speed operation, where the motor speed can be adjusted based on the load requirements, resulting in energy savings and enhanced process control.
  • Energy Efficiency: VFDs contribute to improved energy efficiency of AC motors. By controlling the motor speed based on the load demand, VFDs eliminate the energy wastage that occurs when motors run at full speed even when the load is light. The ability to match the motor speed to the required load reduces energy consumption and results in significant energy savings. In applications where the load varies widely, such as HVAC systems, pumps, and fans, VFDs can provide substantial energy efficiency improvements.
  • Soft Start and Stop: VFDs offer soft start and stop capabilities for AC motors. Instead of abruptly starting or stopping the motor, which can cause mechanical stress and electrical disturbances, VFDs gradually ramp up or down the motor speed. This soft start and stop feature reduces mechanical wear and tear, extends the motor’s lifespan, and minimizes voltage dips or spikes in the electrical system. It also eliminates the need for additional mechanical devices, such as motor starters or brakes, improving overall system reliability and performance.
  • Precision Control and Process Optimization: VFDs enable precise control over AC motor performance, allowing for optimized process control in various applications. The ability to adjust motor speed and torque with high accuracy enables fine-tuning of system parameters, such as flow rates, pressure, or temperature. This precision control enhances overall system performance, improves product quality, and can result in energy savings by eliminating inefficiencies or overcompensation.
  • Motor Protection and Diagnostic Capabilities: VFDs provide advanced motor protection features and diagnostic capabilities. They can monitor motor operating conditions, such as temperature, current, and voltage, and detect abnormalities or faults in real-time. VFDs can then respond by adjusting motor parameters, issuing alerts, or triggering shutdowns to protect the motor from damage. These protection and diagnostic features help prevent motor failures, reduce downtime, and enable predictive maintenance, resulting in improved motor reliability and performance.
  • Harmonics and Power Quality: VFDs can introduce harmonics into the electrical system due to the switching nature of their operation. Harmonics are undesirable voltage and current distortions that can impact power quality and cause issues in the electrical distribution network. However, modern VFDs often include built-in harmonic mitigation measures, such as line reactors or harmonic filters, to minimize harmonics and ensure compliance with power quality standards.

In summary, VFDs have a profound impact on the performance of AC motors. They enable speed control, enhance energy efficiency, provide soft start and stop capabilities, enable precision control and process optimization, offer motor protection and diagnostic features, and address power quality considerations. The use of VFDs in AC motor applications can lead to improved system performance, energy savings, increased reliability, and enhanced control over various industrial and commercial processes.

induction motor

What are the safety considerations when working with or around AC motors?

Working with or around AC motors requires careful attention to safety to prevent accidents, injuries, and electrical hazards. Here are some important safety considerations to keep in mind:

  • Electrical Hazards: AC motors operate on high voltage electrical systems, which pose a significant electrical hazard. It is essential to follow proper lockout/tagout procedures when working on motors to ensure that they are de-energized and cannot accidentally start up. Only qualified personnel should perform electrical work on motors, and they should use appropriate personal protective equipment (PPE), such as insulated gloves, safety glasses, and arc flash protection, to protect themselves from electrical shocks and arc flash incidents.
  • Mechanical Hazards: AC motors often drive mechanical equipment, such as pumps, fans, or conveyors, which can present mechanical hazards. When working on or near motors, it is crucial to be aware of rotating parts, belts, pulleys, or couplings that can cause entanglement or crushing injuries. Guards and safety barriers should be in place to prevent accidental contact with moving parts, and proper machine guarding principles should be followed. Lockout/tagout procedures should also be applied to the associated mechanical equipment to ensure it is safely de-energized during maintenance or repair.
  • Fire and Thermal Hazards: AC motors can generate heat during operation, and in some cases, excessive heat can pose a fire hazard. It is important to ensure that motors are adequately ventilated to dissipate heat and prevent overheating. Motor enclosures and cooling systems should be inspected regularly to ensure proper functioning. Additionally, combustible materials should be kept away from motors to reduce the risk of fire. If a motor shows signs of overheating or emits a burning smell, it should be immediately shut down and inspected by a qualified professional.
  • Proper Installation and Grounding: AC motors should be installed and grounded correctly to ensure electrical safety. Motors should be installed according to manufacturer guidelines, including proper alignment, mounting, and connection of electrical cables. Adequate grounding is essential to prevent electrical shocks and ensure the safe dissipation of fault currents. Grounding conductors, such as grounding rods or grounding straps, should be properly installed and regularly inspected to maintain their integrity.
  • Safe Handling and Lifting: AC motors can be heavy and require proper handling and lifting techniques to prevent musculoskeletal injuries. When moving or lifting motors, equipment such as cranes, hoists, or forklifts should be used, and personnel should be trained in safe lifting practices. It is important to avoid overexertion and use proper lifting tools, such as slings or lifting straps, to distribute the weight evenly and prevent strain or injury.
  • Training and Awareness: Proper training and awareness are critical for working safely with or around AC motors. Workers should receive training on electrical safety, lockout/tagout procedures, personal protective equipment usage, and safe work practices. They should be familiar with the specific hazards associated with AC motors and understand the appropriate safety precautions to take. Regular safety meetings and reminders can help reinforce safe practices and keep safety at the forefront of everyone’s minds.

It is important to note that the safety considerations mentioned above are general guidelines. Specific safety requirements may vary depending on the motor size, voltage, and the specific workplace regulations and standards in place. It is crucial to consult relevant safety codes, regulations, and industry best practices to ensure compliance and maintain a safe working environment when working with or around AC motors.

induction motor

Are there different types of AC motors, and what are their specific applications?

Yes, there are different types of AC motors, each with its own design, characteristics, and applications. The main types of AC motors include:

  1. Induction Motors: Induction motors are the most commonly used type of AC motor. They are robust, reliable, and suitable for a wide range of applications. Induction motors operate based on the principle of electromagnetic induction. They consist of a stator with stator windings and a rotor with short-circuited conductive bars or coils. The rotating magnetic field produced by the stator windings induces currents in the rotor, creating a magnetic field that interacts with the stator field and generates torque. Induction motors are widely used in industries such as manufacturing, HVAC systems, pumps, fans, compressors, and conveyor systems.
  2. Synchronous Motors: Synchronous motors are another type of AC motor commonly used in applications that require precise speed control. They operate at synchronous speed, which is determined by the frequency of the AC power supply and the number of motor poles. Synchronous motors have a rotor with electromagnets that are magnetized by direct current, allowing the rotor to lock onto the rotating magnetic field of the stator and rotate at the same speed. Synchronous motors are often used in applications such as industrial machinery, generators, compressors, and large HVAC systems.
  3. Brushless DC Motors: While the name suggests “DC,” brushless DC motors are actually driven by AC power. They utilize electronic commutation instead of mechanical brushes for switching the current in the motor windings. Brushless DC motors offer high efficiency, low maintenance, and precise control over speed and torque. They are commonly used in applications such as electric vehicles, robotics, computer disk drives, aerospace systems, and consumer electronics.
  4. Universal Motors: Universal motors are versatile motors that can operate on both AC and DC power. They are designed with a wound stator and a commutator rotor. Universal motors offer high starting torque and can achieve high speeds. They are commonly used in applications such as portable power tools, vacuum cleaners, food mixers, and small appliances.
  5. Shaded Pole Motors: Shaded pole motors are simple and inexpensive AC motors. They have a single-phase stator and a squirrel cage rotor. Shaded pole motors are characterized by low starting torque and relatively low efficiency. Due to their simple design and low cost, they are commonly used in applications such as small fans, refrigeration equipment, and appliances.

These are some of the main types of AC motors, each with its unique features and applications. The selection of an AC motor type depends on factors such as the required torque, speed control requirements, efficiency, cost, and environmental conditions. Understanding the specific characteristics and applications of each type allows for choosing the most suitable motor for a given application.

China manufacturer Y2 Ykk Yks High Voltage AC Squirrel Cage Asynchronous Induction Motor   vacuum pump brakesChina manufacturer Y2 Ykk Yks High Voltage AC Squirrel Cage Asynchronous Induction Motor   vacuum pump brakes