China Hot selling Ye3/Ie3 0.12-22kw Aluminum Shell AC Three-Phase Asynchronous Motor vacuum pump connector

Product Description

YE3/IE3 Aluminum Case Easy to Maintain Three-Phase Asynchronous Motor(0.12-22kw)

Factory advantage
1.30 years of history
2. Competitive prices
3. Quality Assurance
Four. Fast Delivery Time: General model about 15-20 days, special model about 30 days
Each process is 100% tested and 100% selective in raw materials
5. Be Efficient
6. Low Noise
7. Live Long
8. Save Energy
9. Slight vibration
10. Professional service/Patience
11. Warranty period: 12 months from the date of delivery
Main Markets: South , Europe, Middle East, Southest Asia, Africa, etc

Product description
Canglong Motors YS motor features:
Frame material: cast iron
Standard Color: Silver or custom
Standard frequency: 50 Hz (available on other frequencies)
Ambient air temperature: -15 C ≤0≤40 ° C
Connection: Star-connection for 3KW or less whereas delta-connection for 4KW or more.
Altitude: no more than 1000 meters
Available in 2, 4, 6,8 pole for 0.21kW and above
Efficiency level: IE3(50Hz) according to IEC 60034-30.
Installation: B 3, B 5, B35, etc. , in accordance with IEC 60034-7 standard
Protection Level: IP55(IEC 60034-5)
Insulation: Class F (155 degrees Celsius)
Cooling mode: IC 411, IEC 60034-6 standard, self-fan, independent cooling fan
Working Height: not exceeding 1000m above sea level (IEC 60034-1)
If there is no other request in the order or agreement, terminal box standard position is at the right side of the frame; data above may be changed without prior notice.   
WHY  CHOOSE  US  ?
1.We are professional  electric motor manufacture for  20 years since 1996.

2.We have best quality materials to make our electric motors best performance.

3.Our products are 100% brand new , 100% cooper wire , 100% output.

4.We have advanced and automated machines such as high speed punching machines, swing punching machines, machines to form the rotors ,stators etc. in 1 piece, automated packing machines which can produce nice appearance and good performance motors while decrease the labor cost and mechanical loss .

5.We have professional financial department who are good at calculating and controlling the cost and capital operation which could make most favorable prices for our customers.

6.We have a strong R&D team, which can develop and produce products according to drawings or samples provided by customers.

7.We have our own pump and motor production line, raw materials processing, factory direct sales, inexpensive.

8.We are only 200 kilometers away from HangZhou port, which is very convenient for export.

TECHINICAL DATA:
 

Type Rated Output Rated Speed Eff Power factor Rated Current locked torque maximum torque locked current
 rated torque  rated torque rated current
KW HP (r.p.m) (%) (cosθ) A Tst/Tn Tmax/Tn Ist/In
380V 50Hz synchronous Speed 3000r/min(2 poles)
YS-6322 0.25 1/3 2730 72 0.78 0.68 2.3 2.3 6
YS-7112 0.37 1/2 2760 73.5 0.8 0.96 2.3 2.3 6
YS-7122 0.55 3/4 2770 75.5 0.82 1.35 2.3 2.3 6
YS-8012 0.75 1 2770 76.5 0.85 1.75 2.2 2.3 6
YS-8571 1.1 1.5 2800 77 0.85 2.55 2.2 2.3 7
YS-90S-2 1.5 2 2840 78.5 0.85 3.42 2.2 2.3 7
YS-90L-2 2.2 3 2840 81 0.86 4.8 2.2 2.3 7
YE2-100L-2 3 4 2890 84.6 0.87 6.17 2.2 2.3 7.8
YE2-112M-2 4 5.5 2910 85.8 0.88 8.04 2.2 2.3 8.3
YE2-132S1-2 5.5 7.5 2930 87 0.86 11.2 2 2.3 8.3
YE2-132S2-2 7.5 10 2840 88.1 0.88 14.6 2 2.3 7.9
YE2-160M1-2 11 15 2930 89.4 0.89 21 2 2.3 8.1
YE2-160M2-2 15 20 2930 90.3 0.89 28.4 2 2.3 8.1
YE2-160L-2 18.5 25 2935 90.9 0.89 34.7 2 2.3 8.2
YE2-180M-2 22 30 2940 91.3 0.88 41.6 2 2.3 8.2
380V 50Hz synchronous Speed 1500r/min(4 poles)
YS-7114 0.25 1/3 1350 67 0.68 0.83 2.4 2.4 6
YS-7124 0.37 1/2 1350 69.5 0.72 1.12 2.4 2.4 6
YS-8014 0.55 3/4 1380 73.5 0.73 1.56 2.4 2.4 6
YS-8571 0.75 1 1390 75.5 0.75 2.01 2.3 2.4 6.5
YS-90S-4 1.1 1.5 1400 78 0.78 2.75 2.3 2.4 6.5
YS-90L-4 1.5 2 1400 79 0.79 3.65 2.3 2.4 6.5
YE2-100L1-4 2.2 3 1440 84.3 0.81 4.9 2.3 2.3 7.6
YE2-100L2-4 3 4 1440 85.5 0.82 6.5 2.3 2.3 7.6
YE2-112M-4 4 5.5 1440 86.6 0.82 8.56 2.2 2.3 7.8
YE2-132S-4 5.5 7.5 1450 87.7 0.83 11.5 2 2.3 7.9
YE2-132M-4 7.5 10 1450 88.7 0.84 15.3 2 2.3 7.5
YE2-160M-4 11 15 1460 89.8 0.84 22.2 2.2 2.3 7.7
YE2-160L-4 15 20 1460 90.6 0.85 29.6 2.2 2.3 7.8
YE2-180M-4 18.5 25 1470 91.2 0.86 35.8 2 2.3 7.8
YE2-180L-4 22 30 1470 91.6 0.86 42.4 2 2.3 7.8
380V 50Hz synchronous Speed 1000r/min(6 poles)
YS-7126 0.25 1/3 910 63 0.62 0.97 2 2 5.5
YS-8016 0.37 1/2 910 68 0.62 1.33 2 2 5.5
YS-8026 0.55 3/4 910 71 0.64 1.84 2 2 5.5
YS-90S-6 0.75 1 920 73 0.68 2.3 2 2.1 5.5
YS-90L-6 1.1 1.5 920 74 0.7 3.23 2 2.1 6
YE2-100L-6 1.5 2 940 79.8 0.75 3.8 2 2.1 6.5
YE2-112M-6 2.2 3 960 81.8 0.76 5.38 2 2.1 6.6
YE2-132S-6 3 4 960 83.3 0.76 7.2 2 2.1 6.8
YE2-132M1-6 4 5.5 960 84.6 0.76 9.45 2 2.1 6.8
YE2-132M2-6 5.5 7.5 960 86 0.77 12.6 2 2.1 7
YE2-160M-6 7.5 10 970 87.2 0.78 16.8 2 2.1 7
YE2-160L-6 11 15 970 88.7 0.78 24.2 2 2.1 7.2
YE2-180L-6 15 20 970 89.7 0.81 31.4 2 2.1 7.3
380V 50Hz synchronous Speed 750r/min(8 poles)
YS-7118 0.09 1/8 600 40 0.57 0.6 1.8 1.9 2.8
YS-7128 0.12 1/6 600 45 0.57 0.71 1.8 1.9 2.8
YS-8018 0.18 1/4 645 51 0.61 0.88 1.8 2 3.3
YS-8571 0.25 1/3 645 54 0.61 1.15 1.8 2 3.3
YS-90S-8 0.37 1/2 670 62 0.61 1.49 1.8 2 4
YS-90L-8 0.55 3/4 670 63 0.61 2.17 1.8 2.1 4

                                                                                                                                                                                                                                                                                                                                                                                                         

1.BFlange 9.Key 17.Rear endshield 25.Terminal box cover 33.Brasslug
2.B4Flange 10.Rotor 18.Fan 26.Screw  
3.Front  endshield 11.Stator 19.Fan cowl 27.Earth mark  
4.Shaft cover 12.Pedestal 20.FancowlScrew 28.Brass washer  
5.Spring washer 13.Pedestal bolt 21.Fan clamp 29.Deductioncap  
6.Vring Oil seal 14.Nameplate 22.Cable gland 30.Brassnet  
7.Bolt 15.Main frame 23.Terminal box base 31.Termiani board  
8.Bearing 16.Wave washer 24.Gasket 32.Leather washer  

                 


/* January 22, 2571 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

Application: Industrial, Universal, Power Tools, Fan/Cooling Tower/Cutting Machine
Operating Speed: Constant Speed
Number of Stator: Three-Phase
Species: Ye3/Ie3/Ys
Rotor Structure: Squirrel-Cage
Casing Protection: Closed Type
Samples:
US$ 50/Piece
1 Piece(Min.Order)

|

Customization:
Available

|

induction motor

Are there environmental considerations associated with the use of AC motors?

Yes, there are several environmental considerations associated with the use of AC motors. These considerations are primarily related to energy consumption, greenhouse gas emissions, and the disposal of motors at the end of their life cycle. Let’s explore these environmental considerations in detail:

  • Energy Efficiency: AC motors can have varying levels of energy efficiency, which directly impacts their environmental impact. Motors with higher efficiency convert a larger percentage of electrical energy into useful mechanical work, resulting in reduced energy consumption. By selecting and using high-efficiency AC motors, energy usage can be minimized, leading to lower greenhouse gas emissions and reduced reliance on fossil fuels for electricity generation.
  • Greenhouse Gas Emissions: The electricity consumed by AC motors is often produced by power plants that burn fossil fuels, such as coal, natural gas, or oil. The generation of electricity from these fossil fuels releases greenhouse gases, contributing to climate change. By employing energy-efficient motors and optimizing motor systems, businesses and individuals can reduce their electricity demand, leading to lower greenhouse gas emissions and a smaller carbon footprint.
  • Motor Disposal and Recycling: AC motors contain various materials, including metals, plastics, and electrical components. At the end of their life cycle, proper disposal or recycling is important to minimize their environmental impact. Some components, such as copper windings and steel casings, can be recycled, reducing the need for new raw materials and energy-intensive manufacturing processes. It is crucial to follow local regulations and guidelines for the disposal and recycling of motors to prevent environmental pollution and promote resource conservation.
  • Manufacturing and Production: The manufacturing and production processes associated with AC motors can have environmental implications. The extraction and processing of raw materials, such as metals and plastics, can result in habitat destruction, energy consumption, and greenhouse gas emissions. Additionally, the manufacturing processes themselves can generate waste and pollutants. Motor manufacturers can mitigate these environmental impacts by adopting sustainable practices, using recycled materials, reducing waste generation, and implementing energy-efficient production methods.
  • Life Cycle Assessment: Conducting a life cycle assessment (LCA) of AC motors can provide a holistic view of their environmental impact. An LCA considers the environmental aspects associated with the entire life cycle of the motor, including raw material extraction, manufacturing, transportation, use, and end-of-life disposal or recycling. By analyzing the different stages of the motor’s life cycle, stakeholders can identify opportunities for improvement, such as optimizing energy efficiency, reducing emissions, and implementing sustainable practices.

To address these environmental considerations, governments, organizations, and industry standards bodies have developed regulations and guidelines to promote energy efficiency and reduce the environmental impact of AC motors. These include efficiency standards, labeling programs, and incentives for the use of high-efficiency motors. Additionally, initiatives promoting motor system optimization, such as proper motor sizing, maintenance, and control, can further enhance energy efficiency and minimize environmental impact.

In summary, the environmental considerations associated with the use of AC motors include energy efficiency, greenhouse gas emissions, motor disposal and recycling, manufacturing processes, and life cycle assessment. By prioritizing energy efficiency, proper disposal, recycling, and sustainable manufacturing practices, the environmental impact of AC motors can be minimized, contributing to a more sustainable and environmentally conscious approach to motor usage.

induction motor

Where can individuals or businesses find reliable information on selecting, installing, and maintaining AC motors?

When seeking information on selecting, installing, and maintaining AC motors, individuals and businesses can refer to various reliable sources. These sources provide valuable guidance, recommendations, and best practices related to AC motors. Here are some places where one can find reliable information:

  • Manufacturer’s Documentation: AC motor manufacturers often provide detailed documentation, including product catalogs, technical specifications, installation guides, and maintenance manuals. These documents offer specific information about their motors, such as performance characteristics, electrical requirements, mounting instructions, and recommended maintenance procedures. Manufacturers’ websites are a common source for accessing these resources.
  • Industry Associations: Industry associations related to electrical engineering, motor manufacturing, or specific applications (e.g., HVAC, pumps, or industrial machinery) can be excellent resources for reliable information. These associations often publish technical articles, guidelines, and standards that cover a wide range of topics, including motor selection, installation practices, efficiency standards, and maintenance recommendations. Examples of such associations include the National Electrical Manufacturers Association (NEMA), the Institute of Electrical and Electronics Engineers (IEEE), and the Air Conditioning, Heating, and Refrigeration Institute (AHRI).
  • Professional Electricians and Engineers: Consulting with professional electricians or electrical engineers who specialize in motor applications can provide valuable insights. These professionals possess practical knowledge and experience in selecting, installing, and maintaining AC motors. They can offer personalized advice based on specific project requirements and industry best practices.
  • Energy Efficiency Programs and Agencies: Energy efficiency programs and agencies, such as government departments, utility companies, or environmental organizations, often provide resources and guidance on energy-efficient motor selection and operation. These programs may offer information on motor efficiency standards, rebate programs for high-efficiency motors, and energy-saving practices. Examples include the U.S. Department of Energy (DOE) and its Energy Star program.
  • Online Technical Forums and Communities: Online forums and communities focused on electrical engineering, motor applications, or specific industries can be valuable sources of information. Participating in these forums allows individuals and businesses to interact with experts, discuss motor-related topics, and seek advice from professionals and enthusiasts who have firsthand experience with AC motors.
  • Books and Publications: Books and technical publications dedicated to electrical engineering, motor technology, or specific applications can provide comprehensive information on AC motors. These resources cover topics ranging from motor theory and design principles to practical installation techniques and maintenance procedures. Libraries, bookstores, and online retailers offer a wide selection of relevant publications.

When accessing information from these sources, it is important to ensure that the information is up-to-date, reliable, and relevant to the specific application or requirements. Consulting multiple sources and cross-referencing information can help verify accuracy and establish a well-rounded understanding of AC motor selection, installation, and maintenance.

induction motor

What are the main components of an AC motor, and how do they contribute to its operation?

An AC motor consists of several key components that work together to facilitate its operation. These components include:

  1. Stator: The stator is the stationary part of an AC motor. It is typically made of a laminated core that provides a path for the magnetic flux. The stator contains stator windings, which are coils of wire wound around the stator core. The stator windings are connected to an AC power source and produce a rotating magnetic field when energized. The rotating magnetic field is a crucial element in generating the torque required for the motor’s operation.
  2. Rotor: The rotor is the rotating part of an AC motor. It is located inside the stator and is connected to a shaft. The rotor can have different designs depending on the type of AC motor. In an induction motor, the rotor does not have electrical connections. Instead, it contains conductive bars or coils that are short-circuited. The rotating magnetic field of the stator induces currents in the short-circuited rotor conductors, creating a magnetic field that interacts with the stator field and generates torque, causing the rotor to rotate. In a synchronous motor, the rotor contains electromagnets that are magnetized by direct current, allowing the rotor to lock onto the rotating magnetic field of the stator and rotate at the same speed.
  3. Bearing: Bearings are used to support and facilitate the smooth rotation of the rotor shaft. They reduce friction and allow the rotor to rotate freely within the motor. Bearings are typically located at both ends of the motor shaft and are designed to withstand the axial and radial forces generated during operation.
  4. End Bells: The end bells, also known as end covers or end brackets, enclose the motor’s stator and rotor assembly. They provide mechanical support and protection for the internal components of the motor. End bells are typically made of metal and are designed to provide a housing for the bearings and secure the motor to its mounting structure.
  5. Fan or Cooling System: AC motors often generate heat during operation. To prevent overheating and ensure proper functioning, AC motors are equipped with fans or cooling systems. These help dissipate heat by circulating air or directing airflow over the motor’s components, including the stator and rotor windings. Effective cooling is crucial for maintaining the motor’s efficiency and extending its lifespan.
  6. Terminal Box or Connection Box: The terminal box is a housing located on the outside of the motor that provides access to the motor’s electrical connections. It contains terminals or connection points where external wires can be connected to supply power to the motor. The terminal box ensures a safe and secure connection of the motor to the electrical system.
  7. Additional Components: Depending on the specific design and application, AC motors may include additional components such as capacitors, centrifugal switches, brushes (in certain types of AC motors), and other control devices. These components are used for various purposes, such as improving motor performance, providing starting assistance, or enabling specific control features.

Each of these components plays a crucial role in the operation of an AC motor. The stator and rotor are the primary components responsible for generating the rotating magnetic field and converting electrical energy into mechanical motion. The bearings ensure smooth rotation of the rotor shaft, while the end bells provide structural support and protection. The fan or cooling system helps maintain optimal operating temperatures, and the terminal box allows for proper electrical connections. Additional components are incorporated as necessary to enhance motor performance and enable specific functionalities.

China Hot selling Ye3/Ie3 0.12-22kw Aluminum Shell AC Three-Phase Asynchronous Motor   vacuum pump connector	China Hot selling Ye3/Ie3 0.12-22kw Aluminum Shell AC Three-Phase Asynchronous Motor   vacuum pump connector
editor by CX 2024-05-10