{"id":3145,"date":"2026-01-16T09:17:36","date_gmt":"2026-01-16T09:17:36","guid":{"rendered":"https:\/\/acmotors.top\/?post_type=product&#038;p=3145"},"modified":"2026-01-20T01:10:16","modified_gmt":"2026-01-20T01:10:16","slug":"ep-ml-series-capacitor-running-and-starting-single-phase-asynchronous-motor","status":"publish","type":"product","link":"https:\/\/acmotors.top\/ms\/product\/ep-ml-series-capacitor-running-and-starting-single-phase-asynchronous-motor\/","title":{"rendered":"EP-ML Series Capacitor Running and Starting Single Phase Asynchronous Motor"},"content":{"rendered":"<h2 style=\"color: #002b5e; margin-top: 50px; font-size: 24px; border-left: 5px solid #ff9900; padding-left: 15px;\">1. Technical Specifications Matrix<\/h2>\n<div style=\"border-left: 6px solid #0056b3; background-color: #eef4fb; padding: 35px; margin-bottom: 50px; border-radius: 0 8px 8px 0;\">\n<h3 style=\"text-align: center;\"><strong>ML Series Single Phase Asynchronous Motor Technical Data:<\/strong><\/h3>\n<table style=\"width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td rowspan=\"2\">Type<\/td>\n<td colspan=\"2\">Rated Power<\/td>\n<td colspan=\"3\">Rated Current (A)<\/td>\n<td>Rated Speed<\/td>\n<td>Efficiency<\/td>\n<td>Power Factor<\/td>\n<td>Rated Torque<\/td>\n<td>Ist\/In<\/td>\n<td>Tst\/Tn<\/td>\n<td>Tmax\/Tn<\/td>\n<td>Noise<\/td>\n<td>Weight<\/td>\n<\/tr>\n<tr>\n<td>(kW)<\/td>\n<td>(HP)<\/td>\n<td>110V<\/td>\n<td>220V<\/td>\n<td>240V<\/td>\n<td>(r\/min)<\/td>\n<td>\u00a0(\u03b7%)<\/td>\n<td>(cos\u03c6)<\/td>\n<td>(N.m)<\/td>\n<td>(times)<\/td>\n<td>(times)<\/td>\n<td>(times)<\/td>\n<td>dB(A)<\/td>\n<td>(kg)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\"><strong>Synchronous Speed 3000 r\/min = 2-poles (50Hz)<\/strong><\/td>\n<\/tr>\n<tr>\n<td>ML631-2<\/td>\n<td>0.18KW<\/td>\n<td>0.25HP<\/td>\n<td>2.89<\/td>\n<td>1.44<\/td>\n<td>1.32<\/td>\n<td>2710<\/td>\n<td>63<\/td>\n<td>0.9<\/td>\n<td>0.63<\/td>\n<td>5.8<\/td>\n<td>2.5<\/td>\n<td>1.6<\/td>\n<td>70<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<td>ML632-2<\/td>\n<td>0.25KW<\/td>\n<td>0.34HP<\/td>\n<td>3.95<\/td>\n<td>1.97<\/td>\n<td>1.81<\/td>\n<td>2710<\/td>\n<td>64<\/td>\n<td>0.9<\/td>\n<td>0.88<\/td>\n<td>5.3<\/td>\n<td>2.5<\/td>\n<td>1.6<\/td>\n<td>73<\/td>\n<td>4.5<\/td>\n<\/tr>\n<tr>\n<td>ML711-2<\/td>\n<td>0.37KW<\/td>\n<td>0.5HP<\/td>\n<td>5.56<\/td>\n<td>2.78<\/td>\n<td>2.55<\/td>\n<td>2780<\/td>\n<td>65<\/td>\n<td>0.93<\/td>\n<td>1.27<\/td>\n<td>5.6<\/td>\n<td>2.5<\/td>\n<td>1.8<\/td>\n<td>75<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<td>ML712-2<\/td>\n<td>0.55KW<\/td>\n<td>0.75HP<\/td>\n<td>7.91<\/td>\n<td>3.95<\/td>\n<td>3.62<\/td>\n<td>2790<\/td>\n<td>68<\/td>\n<td>0.93<\/td>\n<td>1.88<\/td>\n<td>5.3<\/td>\n<td>2.5<\/td>\n<td>1.8<\/td>\n<td>76<\/td>\n<td>6.5<\/td>\n<\/tr>\n<tr>\n<td>ML801-2<\/td>\n<td>0.75KW<\/td>\n<td>1HP<\/td>\n<td>10.2<\/td>\n<td>5.09<\/td>\n<td>4.67<\/td>\n<td>2800<\/td>\n<td>72<\/td>\n<td>0.93<\/td>\n<td>2.56<\/td>\n<td>6.2<\/td>\n<td>2.5<\/td>\n<td>1.8<\/td>\n<td>76<\/td>\n<td>9<\/td>\n<\/tr>\n<tr>\n<td>ML802-2<\/td>\n<td>1.1KW<\/td>\n<td>1.5HP<\/td>\n<td>14.7<\/td>\n<td>7.36<\/td>\n<td>6.75<\/td>\n<td>2810<\/td>\n<td>73<\/td>\n<td>0.93<\/td>\n<td>3.74<\/td>\n<td>5.7<\/td>\n<td>2.5<\/td>\n<td>1.8<\/td>\n<td>79<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>ML90S-2<\/td>\n<td>1.5KW<\/td>\n<td>2HP<\/td>\n<td>19.8<\/td>\n<td>9.91<\/td>\n<td>9.08<\/td>\n<td>2810<\/td>\n<td>74<\/td>\n<td>0.93<\/td>\n<td>5.10<\/td>\n<td>5.8<\/td>\n<td>2.5<\/td>\n<td>1.8<\/td>\n<td>84<\/td>\n<td>13<\/td>\n<\/tr>\n<tr>\n<td>ML90L-2<\/td>\n<td>2.2KW<\/td>\n<td>3HP<\/td>\n<td>28.4<\/td>\n<td>14.2<\/td>\n<td>13.0<\/td>\n<td>2810<\/td>\n<td>75<\/td>\n<td>0.94<\/td>\n<td>7.48<\/td>\n<td>5.5<\/td>\n<td>2.5<\/td>\n<td>1.8<\/td>\n<td>84<\/td>\n<td>14<\/td>\n<\/tr>\n<tr>\n<td>ML100L-2<\/td>\n<td>3KW<\/td>\n<td>4HP<\/td>\n<td>37.3<\/td>\n<td>18.6<\/td>\n<td>17.1<\/td>\n<td>2830<\/td>\n<td>77<\/td>\n<td>0.95<\/td>\n<td>10.1<\/td>\n<td>6.2<\/td>\n<td>2.5<\/td>\n<td>1.7<\/td>\n<td>88<\/td>\n<td>24<\/td>\n<\/tr>\n<tr>\n<td>ML112M-2<\/td>\n<td>4KW<\/td>\n<td>5.5HP<\/td>\n<td>47.8<\/td>\n<td>23.9<\/td>\n<td>21.9<\/td>\n<td>2850<\/td>\n<td>80<\/td>\n<td>0.95<\/td>\n<td>13.4<\/td>\n<td>6.8<\/td>\n<td>2.5<\/td>\n<td>1.7<\/td>\n<td>90<\/td>\n<td>34<\/td>\n<\/tr>\n<tr>\n<td colspan=\"15\"><strong>Synchronous Speed 1500 r\/min = 4-poles (50Hz)<\/strong><\/td>\n<\/tr>\n<tr>\n<td>ML631-4<\/td>\n<td>0.12KW<\/td>\n<td>0.16HP<\/td>\n<td>2.20<\/td>\n<td>1.10<\/td>\n<td>1.01<\/td>\n<td>1350<\/td>\n<td>55<\/td>\n<td>0.9<\/td>\n<td>0.85<\/td>\n<td>5.7<\/td>\n<td>2.5<\/td>\n<td>1.6<\/td>\n<td>64<\/td>\n<td>4<\/td>\n<\/tr>\n<tr>\n<td>ML632-4<\/td>\n<td>0.18KW<\/td>\n<td>0.25HP<\/td>\n<td>3.25<\/td>\n<td>1.62<\/td>\n<td>1.49<\/td>\n<td>1350<\/td>\n<td>56<\/td>\n<td>0.9<\/td>\n<td>1.27<\/td>\n<td>5.5<\/td>\n<td>2.5<\/td>\n<td>1.6<\/td>\n<td>64<\/td>\n<td>4.5<\/td>\n<\/tr>\n<tr>\n<td>ML711-4<\/td>\n<td>0.25KW<\/td>\n<td>0.34HP<\/td>\n<td>4.21<\/td>\n<td>2.10<\/td>\n<td>1.93<\/td>\n<td>1380<\/td>\n<td>60<\/td>\n<td>0.9<\/td>\n<td>1.73<\/td>\n<td>5.0<\/td>\n<td>2.5<\/td>\n<td>1.7<\/td>\n<td>66<\/td>\n<td>6<\/td>\n<\/tr>\n<tr>\n<td>ML712-4<\/td>\n<td>0.37KW<\/td>\n<td>0.5HP<\/td>\n<td>5.93<\/td>\n<td>2.97<\/td>\n<td>2.72<\/td>\n<td>1380<\/td>\n<td>63<\/td>\n<td>0.9<\/td>\n<td>2.56<\/td>\n<td>5.3<\/td>\n<td>2.5<\/td>\n<td>1.7<\/td>\n<td>68<\/td>\n<td>6.5<\/td>\n<\/tr>\n<tr>\n<td>ML801-4<\/td>\n<td>0.55KW<\/td>\n<td>0.75HP<\/td>\n<td>8.42<\/td>\n<td>4.21<\/td>\n<td>3.86<\/td>\n<td>1400<\/td>\n<td>66<\/td>\n<td>0.9<\/td>\n<td>3.75<\/td>\n<td>5.0<\/td>\n<td>2.5<\/td>\n<td>1.8<\/td>\n<td>71<\/td>\n<td>9.5<\/td>\n<\/tr>\n<tr>\n<td>ML802-4<\/td>\n<td>0.75KW<\/td>\n<td>1HP<\/td>\n<td>11.0<\/td>\n<td>5.49<\/td>\n<td>5.03<\/td>\n<td>1410<\/td>\n<td>69<\/td>\n<td>0.9<\/td>\n<td>5.08<\/td>\n<td>5.7<\/td>\n<td>2.5<\/td>\n<td>1.8<\/td>\n<td>71<\/td>\n<td>10.5<\/td>\n<\/tr>\n<tr>\n<td>ML90S-4<\/td>\n<td>1.1KW<\/td>\n<td>1.5HP<\/td>\n<td>15.1<\/td>\n<td>7.57<\/td>\n<td>6.94<\/td>\n<td>1410<\/td>\n<td>71<\/td>\n<td>0.93<\/td>\n<td>7.45<\/td>\n<td>5.5<\/td>\n<td>2.5<\/td>\n<td>1.8<\/td>\n<td>74<\/td>\n<td>13.5<\/td>\n<\/tr>\n<tr>\n<td>ML90L-4<\/td>\n<td>1.5KW<\/td>\n<td>2HP<\/td>\n<td>20.1<\/td>\n<td>10.0<\/td>\n<td>9.21<\/td>\n<td>1400<\/td>\n<td>73<\/td>\n<td>0.93<\/td>\n<td>10.2<\/td>\n<td>5.7<\/td>\n<td>2.5<\/td>\n<td>1.8<\/td>\n<td>79<\/td>\n<td>14.5<\/td>\n<\/tr>\n<tr>\n<td>ML100L1-4<\/td>\n<td>2.2KW<\/td>\n<td>3HP<\/td>\n<td>29.1<\/td>\n<td>14.5<\/td>\n<td>13.3<\/td>\n<td>1430<\/td>\n<td>74<\/td>\n<td>0.93<\/td>\n<td>14.7<\/td>\n<td>5.4<\/td>\n<td>2.5<\/td>\n<td>1.8<\/td>\n<td>79<\/td>\n<td>24<\/td>\n<\/tr>\n<tr>\n<td>ML100L2-4<\/td>\n<td>3KW<\/td>\n<td>4HP<\/td>\n<td>39.1<\/td>\n<td>19.6<\/td>\n<td>17.9<\/td>\n<td>1440<\/td>\n<td>75<\/td>\n<td>0.93<\/td>\n<td>19.9<\/td>\n<td>5.9<\/td>\n<td>2.5<\/td>\n<td>1.8<\/td>\n<td>83<\/td>\n<td>29<\/td>\n<\/tr>\n<tr>\n<td>ML112M-4<\/td>\n<td>4KW<\/td>\n<td>5.5HP<\/td>\n<td>48.9<\/td>\n<td>24.4<\/td>\n<td>22.4<\/td>\n<td>1440<\/td>\n<td>80<\/td>\n<td>0.93<\/td>\n<td>26.5<\/td>\n<td>6.7<\/td>\n<td>2.5<\/td>\n<td>1.7<\/td>\n<td>86<\/td>\n<td>33<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3 style=\"text-align: center;\"><strong>ML Series Single Phase Asynchronous Motor Installation Dimension:<\/strong><\/h3>\n<table style=\"width: 100%;\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td class=\"et2\" rowspan=\"2\" width=\"137\" height=\"44\"><strong>Type<\/strong><\/td>\n<td class=\"et3\" colspan=\"9\" width=\"681\"><strong>Installation Size<\/strong><\/td>\n<td class=\"et2\" colspan=\"5\" width=\"327\"><strong>Installation Size For B5<\/strong><\/td>\n<td class=\"et2\" colspan=\"5\" width=\"360\"><strong>Installation Size For B14<\/strong><\/td>\n<td class=\"et3\" colspan=\"5\" width=\"360\"><strong>Overall Dimension<\/strong><\/td>\n<\/tr>\n<tr>\n<td class=\"et3\">A<\/td>\n<td class=\"et3\">B<\/td>\n<td class=\"et3\">C<\/td>\n<td class=\"et3\">D<\/td>\n<td class=\"et3\">E<\/td>\n<td class=\"et3\">F<\/td>\n<td class=\"et3\">G<\/td>\n<td class=\"et3\">H<\/td>\n<td class=\"et3\">K<\/td>\n<td class=\"et3\">M<\/td>\n<td class=\"et3\">N<\/td>\n<td class=\"et3\">P<\/td>\n<td class=\"et3\">S<\/td>\n<td class=\"et3\">T<\/td>\n<td class=\"et3\">M<\/td>\n<td class=\"et3\">N<\/td>\n<td class=\"et3\">P<\/td>\n<td class=\"et3\">S<\/td>\n<td class=\"et3\">T<\/td>\n<td class=\"et3\">AB<\/td>\n<td class=\"et3\">AC<\/td>\n<td class=\"et3\">AD<\/td>\n<td class=\"et3\">HD<\/td>\n<td class=\"et3\">L<\/td>\n<\/tr>\n<tr>\n<td class=\"et4\" height=\"22\">56<\/td>\n<td class=\"et4\">90<\/td>\n<td class=\"et4\">71<\/td>\n<td class=\"et4\">36<\/td>\n<td class=\"et4\">9<\/td>\n<td class=\"et4\">20<\/td>\n<td class=\"et4\">3<\/td>\n<td class=\"et5\">7.2<\/td>\n<td class=\"et4\">56<\/td>\n<td class=\"et4\">6<\/td>\n<td class=\"et4\">100<\/td>\n<td class=\"et4\">80<\/td>\n<td class=\"et4\">120<\/td>\n<td class=\"et5\">8.5<\/td>\n<td class=\"et4\">3<\/td>\n<td class=\"et4\">65<\/td>\n<td class=\"et4\">50<\/td>\n<td class=\"et4\">80<\/td>\n<td class=\"et3\">M5<\/td>\n<td class=\"et4\">2<\/td>\n<td class=\"et4\">112<\/td>\n<td class=\"et4\">108<\/td>\n<td class=\"et4\">93<\/td>\n<td class=\"et4\">149<\/td>\n<td class=\"et4\">192<\/td>\n<\/tr>\n<tr>\n<td class=\"et4\" height=\"22\">63<\/td>\n<td class=\"et4\">100<\/td>\n<td class=\"et4\">80<\/td>\n<td class=\"et4\">40<\/td>\n<td class=\"et4\">11<\/td>\n<td class=\"et4\">23<\/td>\n<td class=\"et4\">4<\/td>\n<td class=\"et5\">8.5<\/td>\n<td class=\"et4\">63<\/td>\n<td class=\"et4\">7<\/td>\n<td class=\"et4\">115<\/td>\n<td class=\"et4\">95<\/td>\n<td class=\"et4\">140<\/td>\n<td class=\"et4\">10<\/td>\n<td class=\"et4\">3<\/td>\n<td class=\"et4\">75<\/td>\n<td class=\"et4\">60<\/td>\n<td class=\"et4\">90<\/td>\n<td class=\"et3\">M5<\/td>\n<td class=\"et5\">2.5<\/td>\n<td class=\"et4\">120<\/td>\n<td class=\"et4\">120<\/td>\n<td class=\"et4\">97<\/td>\n<td class=\"et4\">160<\/td>\n<td class=\"et4\">211<\/td>\n<\/tr>\n<tr>\n<td class=\"et4\" height=\"22\">71<\/td>\n<td class=\"et4\">112<\/td>\n<td class=\"et4\">90<\/td>\n<td class=\"et4\">45<\/td>\n<td class=\"et4\">14<\/td>\n<td class=\"et4\">30<\/td>\n<td class=\"et4\">5<\/td>\n<td class=\"et4\">11<\/td>\n<td class=\"et4\">71<\/td>\n<td class=\"et4\">7<\/td>\n<td class=\"et4\">130<\/td>\n<td class=\"et4\">110<\/td>\n<td class=\"et4\">160<\/td>\n<td class=\"et4\">10<\/td>\n<td class=\"et5\">3.5<\/td>\n<td class=\"et4\">85<\/td>\n<td class=\"et4\">70<\/td>\n<td class=\"et4\">105<\/td>\n<td class=\"et3\">M6<\/td>\n<td class=\"et5\">2.5<\/td>\n<td class=\"et4\">135<\/td>\n<td class=\"et4\">135<\/td>\n<td class=\"et4\">107<\/td>\n<td class=\"et4\">178<\/td>\n<td class=\"et4\">246<\/td>\n<\/tr>\n<tr>\n<td class=\"et4\" height=\"22\">80<\/td>\n<td class=\"et4\">125<\/td>\n<td class=\"et4\">100<\/td>\n<td class=\"et4\">50<\/td>\n<td class=\"et4\">19<\/td>\n<td class=\"et4\">40<\/td>\n<td class=\"et4\">6<\/td>\n<td class=\"et5\">15.5<\/td>\n<td class=\"et4\">80<\/td>\n<td class=\"et4\">10<\/td>\n<td class=\"et4\">165<\/td>\n<td class=\"et4\">130<\/td>\n<td class=\"et4\">200<\/td>\n<td class=\"et4\">12<\/td>\n<td class=\"et5\">3.5<\/td>\n<td class=\"et4\">100<\/td>\n<td class=\"et4\">80<\/td>\n<td class=\"et4\">120<\/td>\n<td class=\"et3\">M6<\/td>\n<td class=\"et4\">3<\/td>\n<td class=\"et4\">155<\/td>\n<td class=\"et4\">155<\/td>\n<td class=\"et4\">141<\/td>\n<td class=\"et4\">221<\/td>\n<td class=\"et4\">284<\/td>\n<\/tr>\n<tr>\n<td class=\"et3\" height=\"22\">90S<\/td>\n<td class=\"et4\">140<\/td>\n<td class=\"et4\">100<\/td>\n<td class=\"et4\">56<\/td>\n<td class=\"et4\">24<\/td>\n<td class=\"et4\">50<\/td>\n<td class=\"et4\">8<\/td>\n<td class=\"et4\">20<\/td>\n<td class=\"et4\">90<\/td>\n<td class=\"et4\">10<\/td>\n<td class=\"et4\">165<\/td>\n<td class=\"et4\">130<\/td>\n<td class=\"et4\">200<\/td>\n<td class=\"et4\">12<\/td>\n<td class=\"et5\">3.5<\/td>\n<td class=\"et4\">115<\/td>\n<td class=\"et4\">95<\/td>\n<td class=\"et4\">140<\/td>\n<td class=\"et3\">M8<\/td>\n<td class=\"et4\">3<\/td>\n<td class=\"et4\">175<\/td>\n<td class=\"et4\">175<\/td>\n<td class=\"et4\">160<\/td>\n<td class=\"et4\">250<\/td>\n<td class=\"et4\">314<\/td>\n<\/tr>\n<tr>\n<td class=\"et3\" height=\"22\">90L<\/td>\n<td class=\"et4\">140<\/td>\n<td class=\"et4\">125<\/td>\n<td class=\"et4\">56<\/td>\n<td class=\"et4\">24<\/td>\n<td class=\"et4\">50<\/td>\n<td class=\"et4\">8<\/td>\n<td class=\"et4\">20<\/td>\n<td class=\"et4\">90<\/td>\n<td class=\"et4\">10<\/td>\n<td class=\"et4\">165<\/td>\n<td class=\"et4\">130<\/td>\n<td class=\"et4\">200<\/td>\n<td class=\"et4\">12<\/td>\n<td class=\"et5\">3.5<\/td>\n<td class=\"et4\">115<\/td>\n<td class=\"et4\">95<\/td>\n<td class=\"et4\">140<\/td>\n<td class=\"et3\">M8<\/td>\n<td class=\"et4\">3<\/td>\n<td class=\"et4\">175<\/td>\n<td class=\"et4\">175<\/td>\n<td class=\"et4\">160<\/td>\n<td class=\"et4\">250<\/td>\n<td class=\"et4\">339<\/td>\n<\/tr>\n<tr>\n<td class=\"et3\" height=\"22\">100L<\/td>\n<td class=\"et4\">160<\/td>\n<td class=\"et4\">140<\/td>\n<td class=\"et4\">63<\/td>\n<td class=\"et4\">28<\/td>\n<td class=\"et4\">60<\/td>\n<td class=\"et4\">8<\/td>\n<td class=\"et4\">24<\/td>\n<td class=\"et4\">100<\/td>\n<td class=\"et4\">12<\/td>\n<td class=\"et4\">215<\/td>\n<td class=\"et4\">180<\/td>\n<td class=\"et4\">250<\/td>\n<td class=\"et4\">15<\/td>\n<td class=\"et4\">4<\/td>\n<td class=\"et4\">130<\/td>\n<td class=\"et4\">110<\/td>\n<td class=\"et4\">160<\/td>\n<td class=\"et3\">M8<\/td>\n<td class=\"et5\">3.5<\/td>\n<td class=\"et4\">200<\/td>\n<td class=\"et4\">195<\/td>\n<td class=\"et4\">160<\/td>\n<td class=\"et4\">260<\/td>\n<td class=\"et4\">412<\/td>\n<\/tr>\n<tr>\n<td class=\"et3\" height=\"22\">112M<\/td>\n<td class=\"et4\">190<\/td>\n<td class=\"et4\">140<\/td>\n<td class=\"et4\">70<\/td>\n<td class=\"et4\">28<\/td>\n<td class=\"et4\">60<\/td>\n<td class=\"et4\">8<\/td>\n<td class=\"et4\">24<\/td>\n<td class=\"et4\">112<\/td>\n<td class=\"et4\">12<\/td>\n<td class=\"et4\">215<\/td>\n<td class=\"et4\">180<\/td>\n<td class=\"et4\">250<\/td>\n<td class=\"et4\">15<\/td>\n<td class=\"et4\">4<\/td>\n<td class=\"et4\">130<\/td>\n<td class=\"et4\">110<\/td>\n<td class=\"et4\">160<\/td>\n<td class=\"et3\">M8<\/td>\n<td class=\"et5\">3.5<\/td>\n<td class=\"et4\">226<\/td>\n<td class=\"et4\">220<\/td>\n<td class=\"et4\">166<\/td>\n<td class=\"et4\">278<\/td>\n<td class=\"et4\">421<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3148\" src=\"https:\/\/acmotors.top\/wp-content\/uploads\/2026\/01\/acmotors-EP-ML-Series-Capacitor-Running-and-Starting-Single-Phase-Asynchronous-Motor-Parameter-Specifications-Table.webp\" alt=\"acmotors-EP-ML Series Capacitor Running and Starting Single Phase Asynchronous Motor-Parameter Specifications Table\" width=\"1000\" height=\"500\" title=\"\" srcset=\"https:\/\/acmotors.top\/wp-content\/uploads\/2026\/01\/acmotors-EP-ML-Series-Capacitor-Running-and-Starting-Single-Phase-Asynchronous-Motor-Parameter-Specifications-Table.webp 1000w, https:\/\/acmotors.top\/wp-content\/uploads\/2026\/01\/acmotors-EP-ML-Series-Capacitor-Running-and-Starting-Single-Phase-Asynchronous-Motor-Parameter-Specifications-Table-980x490.webp 980w, https:\/\/acmotors.top\/wp-content\/uploads\/2026\/01\/acmotors-EP-ML-Series-Capacitor-Running-and-Starting-Single-Phase-Asynchronous-Motor-Parameter-Specifications-Table-480x240.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1000px, 100vw\" \/><\/p>\n<\/div>\n<div style=\"border-left: 6px solid #0056b3; background-color: #eef4fb; padding: 35px; margin-bottom: 50px; border-radius: 0 8px 8px 0;\">\n<h2 style=\"color: #002b5e; margin-top: 0; font-size: 28px; border-bottom: 2px solid #ddd; padding-bottom: 15px; margin-bottom: 20px;\">2. Strategic Overview: Bridging Torque and Efficiency in Single Phase Systems<\/h2>\n<p style=\"font-size: 16px; margin-bottom: 0; text-align: justify;\">The <strong>EP-ML Series Capacitor Running and Starting Single Phase Asynchronous Motor<\/strong> represents the pinnacle of single-phase engineering, specifically designed to address the unique power grid challenges faced by industries in Colombia. Unlike standard split-phase or single-capacitor motors, the EP-ML series utilizes a sophisticated dual-capacitor architecture. It integrates a high-value start capacitor to deliver immense starting torque (up to 2.5 times the rated torque) and a run capacitor to ensure smooth, energy-efficient operation once the motor reaches speed. This hybrid approach makes the EP-ML series the definitive choice for driving high-inertia loads such as heavy-duty air compressors, centrifugal pumps, and agricultural processing machinery found in the Coffee Triangle and the industrial zones of Bogota. Encased in a premium aluminum alloy housing, these motors offer superior heat dissipation and corrosion resistance against the humid tropical climate. At Colombia Ever-power AC Motors Co., Ltd., we ensure that every unit adheres to IEC 60034 standards, providing a robust, maintenance-friendly solution that minimizes downtime and maximizes productivity for Colombian small and medium enterprises (SMEs) relying on single-phase power.<\/p>\n<\/div>\n<div style=\"display: flex; flex-wrap: wrap; justify-content: space-between; gap: 20px; margin-bottom: 50px;\">\n<div style=\"flex: 1; min-width: 300px; background-color: #ffffff; border: 1px solid #e0e0e0; padding: 25px; border-radius: 8px; box-shadow: 0 5px 15px rgba(0,0,0,0.05); transition: transform 0.3s ease;\">\n<h2 style=\"color: #0056b3; border-bottom: 2px solid #0056b3; padding-bottom: 10px; margin-top: 0;\">3. Five Engineering Highlights<\/h2>\n<ul style=\"list-style-type: none; padding: 0;\">\n<li style=\"margin-bottom: 12px; padding-left: 20px; position: relative;\"><strong>Dual Capacitor System:<\/strong> Combines high starting torque with high running power factor.<\/li>\n<li style=\"margin-bottom: 12px; padding-left: 20px; position: relative;\"><strong>Aluminum Construction:<\/strong> Lightweight, aesthetic, and highly efficient at dissipating thermal buildup.<\/li>\n<li style=\"margin-bottom: 12px; padding-left: 20px; position: relative;\"><strong>Centrifugal Switch:<\/strong> Robust internal mechanism ensures seamless transition from start to run mode.<\/li>\n<li style=\"margin-bottom: 12px; padding-left: 20px; position: relative;\"><strong>High Overload Capacity:<\/strong> Designed to handle temporary load spikes without stalling.<\/li>\n<li style=\"margin-bottom: 12px; padding-left: 20px; position: relative;\"><strong>Voltage Versatility:<\/strong> Available in 110V\/220V dual voltage configurations for Colombian grid flexibility.<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<h2 style=\"color: #002b5e; border-bottom: 3px solid #ff9900; padding-bottom: 10px; margin-top: 60px; font-size: 28px;\">4. Regulatory Compliance: RETIE and Electrical Safety in Colombia<\/h2>\n<p style=\"font-size: 16px; text-align: justify; margin-bottom: 25px;\">In the Colombian electromechanical market, compliance with safety standards is not optional; it is mandatory. The EP-ML Series motors are rigorously tested and manufactured in accordance with the <strong>RETIE (Reglamento T\u00e9cnico de Instalaciones El\u00e9ctricas)<\/strong>. This regulation ensures that all electrical equipment installed in Colombia minimizes the risk of electrocution, fire, and other hazards. Our motors feature high-grade insulation materials (Class B or F) and robust grounding terminals that meet the specifications of <strong>NTC 2050 (C\u00f3digo El\u00e9ctrico Colombiano)<\/strong>. Additionally, the capacitors used in the EP-ML series are certified to withstand the voltage fluctuations often encountered in rural and semi-industrial areas of Colombia, ensuring long lifespan and operational safety. We provide full documentation, including test reports and conformity certificates, to assist our clients in passing local safety inspections and audits.<\/p>\n<h2 style=\"color: #002b5e; border-bottom: 3px solid #ff9900; padding-bottom: 10px; margin-top: 60px; font-size: 28px;\">5. Engineering Mechanics: Working Principle, Metallurgy, and Scenarios<\/h2>\n<p style=\"font-size: 16px; text-align: justify; margin-bottom: 20px;\">The <strong>ac motor working principle<\/strong> of the EP-ML Series is based on creating a rotating magnetic field from a single-phase supply using a phase-splitting technique. The stator contains two windings: the main winding and the auxiliary (start) winding. An <strong>ac motor start capacitor<\/strong> is connected in series with the auxiliary winding and a centrifugal switch. This capacitor creates a significant phase shift between the currents in the two windings, generating a powerful starting torque needed to overcome inertia. Once the motor reaches approximately 75% of its synchronous speed, the centrifugal switch opens, disconnecting the start capacitor. However, unlike simple capacitor-start motors, the EP-ML series retains a second &#8220;run&#8221; <strong>ac motor capacitor<\/strong> in the circuit permanently. This run capacitor improves the motor&#8217;s power factor, reduces running current, and minimizes noise and vibration during continuous operation, effectively combining the best attributes of high torque and high efficiency.<\/p>\n<p style=\"font-size: 16px; text-align: justify; margin-bottom: 20px;\">Regarding metallurgy and construction, the EP-ML series sets a high standard. The housing, end shields, and terminal box are high-pressure die-cast from <strong>ADC12 Aluminum Alloy<\/strong>. This material choice offers a superior strength-to-weight ratio compared to cast iron and provides excellent thermal conductivity to keep winding temperatures low. The rotor cage utilizes high-purity die-cast aluminum, dynamically balanced to G2.5 grade to ensure vibration-free performance. The stator laminations are stamped from <strong>DW470 Cold-Rolled Silicon Steel<\/strong>, significantly reducing iron losses (hysteresis and eddy currents). This meticulous material selection ensures the motor can withstand the rigors of continuous duty (S1) in challenging industrial environments.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3147\" src=\"https:\/\/acmotors.top\/wp-content\/uploads\/2026\/01\/acmotors-EP-ML-Series-Capacitor-Running-and-Starting-Single-Phase-Asynchronous-Motor-draft.webp\" alt=\"acmotors-EP-ML Series Capacitor Running and Starting Single Phase Asynchronous Motor-draft\" width=\"1000\" height=\"500\" title=\"\" srcset=\"https:\/\/acmotors.top\/wp-content\/uploads\/2026\/01\/acmotors-EP-ML-Series-Capacitor-Running-and-Starting-Single-Phase-Asynchronous-Motor-draft.webp 1000w, https:\/\/acmotors.top\/wp-content\/uploads\/2026\/01\/acmotors-EP-ML-Series-Capacitor-Running-and-Starting-Single-Phase-Asynchronous-Motor-draft-980x490.webp 980w, https:\/\/acmotors.top\/wp-content\/uploads\/2026\/01\/acmotors-EP-ML-Series-Capacitor-Running-and-Starting-Single-Phase-Asynchronous-Motor-draft-480x240.webp 480w\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) 1000px, 100vw\" \/><\/p>\n<h2 style=\"color: #002b5e; border-bottom: 3px solid #ff9900; padding-bottom: 10px; margin-top: 60px; font-size: 28px;\">6. Application Scenarios in Colombia:<\/h2>\n<p>1. <strong>Construction Sector:<\/strong> Driving cement mixers and stone cutters where high starting torque is essential to move heavy loads from a standstill.<\/p>\n<p>2. <strong>Agricultural Processing:<\/strong> Powering coffee pulping machines and grain mills in remote areas where only single-phase power is available.<\/p>\n<p>3. <strong>Fluid Handling:<\/strong> Operating high-pressure piston pumps and car wash equipment requiring immediate, powerful startup.<\/p>\n<p>4. <strong>Woodworking:<\/strong> Table saws and planers that require consistent speed and power to prevent stalling during cuts.<\/p>\n<h2 style=\"color: #002b5e; border-bottom: 3px solid #ff9900; padding-bottom: 10px; margin-top: 60px; font-size: 28px;\">7. Market Trend Analysis: The Demand for Efficiency in Single-Phase Grids<\/h2>\n<p style=\"font-size: 16px; text-align: justify; margin-bottom: 20px;\">The Colombian market is seeing a distinct shift towards more efficient and reliable single-phase solutions. As urbanization expands and small businesses flourish in areas with limited three-phase infrastructure, the demand for high-performance single-phase motors like the EP-ML series is growing. Traditional single-capacitor motors are being phased out in favor of dual-capacitor models because users require both the high breakaway torque for starting heavy machinery and the energy efficiency provided by a run capacitor. This aligns with global trends where energy conservation is paramount. Furthermore, there is a clear preference for aluminum housings over cast iron in smaller frame sizes (up to 3kW) due to the reduced weight for shipping and installation, as well as the superior aesthetic finish and corrosion resistance in Colombia&#8217;s humid environments. The EP-ML series perfectly addresses these market needs by combining robust torque characteristics with modern, lightweight construction.<\/p>\n<div>\n<h2 style=\"color: #002b5e; border-bottom: 3px solid #ff9900; padding-bottom: 10px; margin-top: 60px; font-size: 28px;\">8. Related Products: Gearboxes and Accessories<\/h2>\n<p data-start=\"157\" data-end=\"585\">Our\u00a0<a href=\"https:\/\/agricultural-gearbox.net\/\" target=\"_blank\" rel=\"noopener\"><strong data-start=\"161\" data-end=\"172\">gearbox<\/strong>\u00a0<\/a>is the perfect companion for the\u00a0<strong data-start=\"206\" data-end=\"270\">EP-YS Series Aluminum Housing Three Phase Asynchronous Motor<\/strong>, offering superior performance and seamless integration in a wide range of industrial applications. Engineered with precision, our gearboxes are designed to efficiently transfer power from the motor to machinery, optimizing torque and speed for various systems like conveyors, air compressors, and industrial fans.<\/p>\n<p data-start=\"587\" data-end=\"991\">Made from high-quality materials, our gearboxes feature robust construction for long-lasting durability, even under heavy loads. The gears are manufactured using advanced heat-treatment processes, ensuring excellent wear resistance and minimal maintenance. With a range of gear ratios, our gearboxes offer the flexibility to adjust motor speed and torque to meet the specific demands of your application.<\/p>\n<p data-start=\"993\" data-end=\"1476\">Whether you\u2019re looking to reduce the rotational speed for high-torque output or increase speed for faster operation, our gearboxes provide a reliable and efficient solution. Additionally, they are designed to work in tandem with the EP-YS motor, enhancing its performance and efficiency. From food processing plants in Bogot\u00e1 to manufacturing units in Medell\u00edn, our gearboxes deliver exceptional reliability and smooth operation, reducing downtime and improving overall productivity.<\/p>\n<\/div>\n<div><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3109\" title=\"EP-YS Series Aluminum Housing Three Phase Asynchronous Motor\" src=\"https:\/\/acmotors.top\/wp-content\/uploads\/2026\/01\/acmotors-related-part-gearbox.webp\" sizes=\"(min-width: 0px) and (max-width: 480px) 480px, (min-width: 481px) and (max-width: 980px) 980px, (min-width: 981px) and (max-width: 1280px) 1280px, (min-width: 1281px) 1536px, 100vw\" srcset=\"https:\/\/acmotors.top\/wp-content\/uploads\/2026\/01\/acmotors-related-part-gearbox.webp 1536w, https:\/\/acmotors.top\/wp-content\/uploads\/2026\/01\/acmotors-related-part-gearbox-1280x853.webp 1280w, https:\/\/acmotors.top\/wp-content\/uploads\/2026\/01\/acmotors-related-part-gearbox-980x653.webp 980w, https:\/\/acmotors.top\/wp-content\/uploads\/2026\/01\/acmotors-related-part-gearbox-480x320.webp 480w\" alt=\"acmotors-related-part-gearbox\" width=\"1536\" height=\"1024\" \/><\/div>\n<h2 style=\"color: #002b5e; border-bottom: 3px solid #ff9900; padding-bottom: 10px; margin-top: 60px; font-size: 28px;\">Frequently Asked Questions (FAQ)<\/h2>\n<div style=\"margin-bottom: 25px; border-bottom: 1px solid #ddd; padding-bottom: 15px;\">\n<h3 style=\"font-size: 20px; color: #333; font-weight: 600;\">Q1. What is the difference between the MC series and the ML series single-phase motors?<\/h3>\n<p style=\"font-size: 16px; color: #555;\">A1. The MC series typically refers to &#8220;Capacitor Start&#8221; motors (one capacitor), designed for high starting torque but lower running efficiency. The EP-ML series is &#8220;Capacitor Start and Capacitor Run&#8221; (two capacitors). The ML series offers the best of both worlds: high starting torque from the start capacitor and high efficiency\/smooth running from the run capacitor, making it superior for heavy-duty applications.<\/p>\n<\/div>\n<div style=\"margin-bottom: 25px; border-bottom: 1px solid #ddd; padding-bottom: 15px;\">\n<h3 style=\"font-size: 20px; color: #333; font-weight: 600;\">Q2. Can I use the EP-ML motor for an air compressor in Bogota?<\/h3>\n<p style=\"font-size: 16px; color: #555;\">A2. Yes, absolutely. Air compressors require a very high starting torque to overcome the pressure in the cylinder head. The EP-ML series, with its dual-capacitor design, is specifically engineered for such high-inertia loads, ensuring reliable startup even if voltage drops slightly, which can happen in industrial zones.<\/p>\n<\/div>\n<div style=\"margin-bottom: 25px; border-bottom: 1px solid #ddd; padding-bottom: 15px;\">\n<h3 style=\"font-size: 20px; color: #333; font-weight: 600;\">Q3. How do I change the rotation direction of the EP-ML motor?<\/h3>\n<p style=\"font-size: 16px; color: #555;\">A3. The rotation direction can be reversed by changing the connection links in the terminal box. You typically need to swap the connections of the auxiliary winding relative to the main winding. A clear <strong>ac motor diagram<\/strong> is provided inside the terminal box cover of every EP-ML motor to guide you safely.<\/p>\n<\/div>\n<div style=\"margin-bottom: 25px; border-bottom: 1px solid #ddd; padding-bottom: 15px;\">\n<h3 style=\"font-size: 20px; color: #333; font-weight: 600;\">Q4. What maintenance is required for the centrifugal switch?<\/h3>\n<p style=\"font-size: 16px; color: #555;\">A4. The centrifugal switch is internal and generally maintenance-free. However, in very dusty environments, dust can accumulate on the contacts. If the motor fails to start or the start capacitor doesn&#8217;t disengage (you hear a humming or the capacitor blows), the switch should be checked by a professional technician. Our IP55 enclosure helps prevent this issue.<\/p>\n<\/div>\n<div style=\"margin-bottom: 25px; border-bottom: 1px solid #ddd; padding-bottom: 15px;\">\n<h3 style=\"font-size: 20px; color: #333; font-weight: 600;\">Q5. Are EP-ML motors compliant with Colombian RETIE regulations?<\/h3>\n<p style=\"font-size: 16px; color: #555;\">A5. Yes. All EP-ML motors sold by Colombia Ever-power are compliant with RETIE regulations. We ensure proper insulation resistance, grounding provisions, and safety labeling to meet the requirements of the Colombian Ministry of Mines and Energy for electrical installations.<\/p>\n<\/div>\n<div style=\"margin-bottom: 25px; border-bottom: 1px solid #ddd; padding-bottom: 15px;\">\n<h3 style=\"font-size: 20px; color: #333; font-weight: 600;\">Q6. Where can I find ac motor start capacitor replacement in Colombia?<\/h3>\n<p style=\"font-size: 16px; color: #555;\">A6. Capacitors are consumable parts. We supply genuine replacement <strong>ac motor start capacitors<\/strong> and run capacitors for our EP-ML series. We can ship these directly to you in Bogota, Medellin, or Cali. It is crucial to replace them with capacitors of the exact same microfarad (\u00b5F) and voltage rating.<\/p>\n<\/div>\n<div style=\"margin-bottom: 25px; border-bottom: 1px solid #ddd; padding-bottom: 15px;\">\n<h3 style=\"font-size: 20px; color: #333; font-weight: 600;\">Q7. What is the difference between ac induction motor and ac synchronous motor?<\/h3>\n<p style=\"font-size: 16px; color: #555;\">A7. The EP-ML is an <strong>ac induction motor<\/strong> (asynchronous). Its rotor spins slightly slower than the magnetic field (slip) to generate torque. It is robust, cheaper, and self-starting. A synchronous motor spins at the exact grid frequency speed but requires complex starting mechanisms and is more expensive, typically used for precise timing or power factor correction.<\/p>\n<\/div>\n<div style=\"margin-bottom: 25px; border-bottom: 1px solid #ddd; padding-bottom: 15px;\">\n<h3 style=\"font-size: 20px; color: #333; font-weight: 600;\">Q8. Can I use this motor with a Variable Frequency Drive (VFD)?<\/h3>\n<p style=\"font-size: 16px; color: #555;\">A8. Generally, single-phase motors with capacitors and centrifugal switches (like the EP-ML) are NOT suitable for use with standard VFDs. VFDs are designed for three-phase motors. Using a VFD on a single-phase capacitor motor can damage the capacitor and the drive. For variable speed, we recommend a three-phase motor with a single-phase input VFD.<\/p>\n<\/div>\n<div style=\"margin-bottom: 25px; border-bottom: 1px solid #ddd; padding-bottom: 15px;\">\n<h3 style=\"font-size: 20px; color: #333; font-weight: 600;\">Q9. How does the price of EP-ML motors compare to cast-iron motors?<\/h3>\n<p style=\"font-size: 16px; color: #555;\">A9. The EP-ML series features an aluminum housing. While aluminum raw material is more expensive than iron, the die-casting process is efficient for smaller frame sizes. This makes the EP-ML competitively priced while offering the added value of being lightweight, rust-resistant, and aesthetically superior to painted cast iron motors.<\/p>\n<\/div>\n<p style=\"text-align: right;\">Editor: PXY<\/p>","protected":false},"excerpt":{"rendered":"<p>The EP-ML Series Capacitor Running and Starting Single Phase Induction Motor is designed to meet the demands of single-phase power grids in Colombia&#8217;s industries. Featuring a dual-capacitor design (start capacitor and run capacitor), this series offers excellent starting torque (up to 2.5 times the rated torque) and smooth, efficient operation. The aluminum alloy housing provides superior heat dissipation and corrosion resistance, making it ideal for heavy-duty applications such as air compressors, centrifugal pumps, and agricultural processing equipment. Compliant with IEC 60034 standards, the EP-ML motor ensures high efficiency and long-term reliability, even in humid and high-temperature environments, and is widely used in Colombia&#8217;s SME sector.<\/p>","protected":false},"featured_media":3146,"comment_status":"open","ping_status":"closed","template":"","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":""},"product_brand":[],"product_cat":[5463],"product_tag":[5470],"class_list":{"0":"post-3145","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-ac-motors","7":"product_tag-ep-ml-series-capacitor-running-and-starting-single-phase-asynchronous-motor","9":"first","10":"instock","11":"shipping-taxable","12":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/acmotors.top\/ms\/wp-json\/wp\/v2\/product\/3145","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/acmotors.top\/ms\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/acmotors.top\/ms\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/acmotors.top\/ms\/wp-json\/wp\/v2\/comments?post=3145"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/acmotors.top\/ms\/wp-json\/wp\/v2\/media\/3146"}],"wp:attachment":[{"href":"https:\/\/acmotors.top\/ms\/wp-json\/wp\/v2\/media?parent=3145"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/acmotors.top\/ms\/wp-json\/wp\/v2\/product_brand?post=3145"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/acmotors.top\/ms\/wp-json\/wp\/v2\/product_cat?post=3145"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/acmotors.top\/ms\/wp-json\/wp\/v2\/product_tag?post=3145"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}