Descrizione del prodotto
Electrical AC Shaded Pole Gear Motor Class F 230V 240V for Air Machine
Product characteristic:
1. Stator size is optional
2. Safe, reliable, low noise, good starting, long life
3. Strong power
Rated voltage 110~120V/220~240V-50/60Hz
Typical used:
Exhaust fan, air purifier, micro-oven, fan, induction cooker, refrigerator, pump, heater, hood oven, blwer, air conditioner, Heater machines, dehumidifiers .
Thermal protector with 1 shot fuse or multi shot fuse
| MODEL | STATOR SIZE | SHAFT DIA | VOLT | INPUT POWER | TORQUE (g.cm) | SPEED RATED |
| YJ4808B | 8mm | 4mm | 110-240V | 6W | 1.12mN.m | 3400RPM |
| YJ4810B | 10mm | 4mm | 110-240V | 10W | 3.42mN.m | 3000RPM |
| YJ4810C | 10mm | 5mm | 110-240V | 14W | 3.82mN.m | 3000RPM |
| YJ4815B | 15mm | 4mm | 110-240V | 11W | 7.97mN.m | 3400RPM |
ABOUT US
Greatupmotor group was established in 2006.we always focus on micro-motors for household and industrial electrical appliance.Currently, we hav are professional micro-motor factories separatlly located in ZheJiang & ZHangZhoug province.It has 50,000 square CHINAMFG plants and more than 500 employees, annual output is 5 million pcs and has 10 million pcs annual producing capacity.After years development,we built a great reputation in the domestic and oversea market and have the trust from our global customers.
We started our business from shaded pole motors, after 10 years development,our products is enlarged to BLDC motors ,capacitor motors ,synchronous motors,stepping motors,servo motors, and PMDC motors.Our products are widely used for making refrigerators, freezers, micro-wave ovens, air warmers, air exhausters, ventilators,ovens, air filter, massage machines and many other equipments.
To design the lastest technology motors and meet our customers requirments,we have the very capable R&D team,to ensure our products quality ,we have very strict manage system for our production department & QC department,to make our cost lower,we have the very professional purchase department, We dedicate to make every details better than we could do.
To offer quick and better service to our customers in Australia and New Zeland,we set up branch office in Australia since 2017 with exprienced consultant to support the business ,which will bring more customers to get know of us.
We will keep doing our job,move CHINAMFG step by step to make our business area wider and brighter.
Our company FAQ for you
(1) D: Che tipo di motori potete fornire?
A:For now,we mainly provide Kitchen Hood Motor,DC Motor,Gear Motor,Fan Motor Refrigerator Motor,Hair Dryer Motor Blender Motor Mixer Motor,
Shade Pole Motor,Capacitor Motor,BLDC Motor PMDC Motor,Synchronous Motor,Stepping Motor etc.
(2) D: È possibile visitare la vostra fabbrica?
A: Sure. But please kindly keep us posted a few days in advance. We need to check our
schedule to see if we are available then.
(3) D: Posso avere dei campioni
A: It depends. If only a few samples for personal use or replacement, I am afraid it will
be difficult for us to provide, because all of our motors are custom made and no stock
available if there is no further needs. If just sample testing before the official order and
our MOQ, price and other terms are acceptable, we’d love to provide samples.
(4) D: Esiste un MOQ per i vostri motori?
R: Sì. Il quantitativo minimo d'ordine è compreso tra 1000 e 10.000 pezzi per i diversi modelli dopo l'approvazione del campione.
Ma per noi va bene anche accettare lotti più piccoli come poche decine, centinaia o migliaia
Per i primi 3 ordini dopo l'approvazione del campione, non è richiesto alcun quantitativo minimo. Tuttavia, è meglio ordinarne meno (ad esempio non più di 5 pezzi), a condizione che la quantità sia sufficiente per eventuali modifiche dopo i test iniziali.
| Applicazione: | Macchina utensile |
|---|---|
| Velocità: | Velocità costante |
| Numero di statore: | Monofase |
| Funzione: | Driving, Control |
| Protezione dell'involucro: | Tipo di protezione |
| Numero di poli: | 4 |
| Personalizzazione: |
Disponibile
|
|
|---|

Are there specific maintenance requirements for AC motors to ensure optimal performance?
Yes, AC motors have specific maintenance requirements to ensure their optimal performance and longevity. Regular maintenance helps prevent unexpected failures, maximizes efficiency, and extends the lifespan of the motor. Here are some key maintenance practices for AC motors:
- Cleaning and Inspection: Regularly clean the motor to remove dust, dirt, and debris that can accumulate on the motor surfaces and hinder heat dissipation. Inspect the motor for any signs of damage, loose connections, or abnormal noise/vibration. Address any issues promptly to prevent further damage.
- Lubrication: Check the motor’s lubrication requirements and ensure proper lubrication of bearings, gears, and other moving parts. Insufficient or excessive lubrication can lead to increased friction, overheating, and premature wear. Follow the manufacturer’s guidelines for lubrication intervals and use the recommended lubricants.
- Belt and Pulley Maintenance: If the motor is coupled with a belt and pulley system, regularly inspect and adjust the tension of the belts. Improper belt tension can affect motor performance and efficiency. Replace worn-out belts and damaged pulleys as needed.
- Cooling System Maintenance: AC motors often have cooling systems such as fans or heat sinks to dissipate heat generated during operation. Ensure that these cooling systems are clean and functioning properly. Remove any obstructions that may impede airflow and compromise cooling efficiency.
- Electrical Connections: Regularly inspect the motor’s electrical connections for signs of loose or corroded terminals. Loose connections can lead to voltage drops, increased resistance, and overheating. Tighten or replace any damaged connections and ensure proper grounding.
- Vibration Analysis: Periodically perform vibration analysis on the motor to detect any abnormal vibrations. Excessive vibration can indicate misalignment, unbalanced rotors, or worn-out bearings. Address the underlying causes of vibration to prevent further damage and ensure smooth operation.
- Motor Testing: Conduct regular motor testing, such as insulation resistance testing and winding resistance measurement, to assess the motor’s electrical condition. These tests can identify insulation breakdown, winding faults, or other electrical issues that may affect motor performance and reliability.
- Professional Maintenance: For more complex maintenance tasks or when dealing with large industrial motors, it is advisable to involve professional technicians or motor specialists. They have the expertise and tools to perform in-depth inspections, repairs, and preventive maintenance procedures.
It’s important to note that specific maintenance requirements may vary depending on the motor type, size, and application. Always refer to the manufacturer’s guidelines and recommendations for the particular AC motor in use. By following proper maintenance practices, AC motors can operate optimally, minimize downtime, and have an extended service life.

I motori a corrente alternata possono essere utilizzati nei sistemi di energia rinnovabile, come le turbine eoliche?
Sì, i motori a corrente alternata possono essere utilizzati nei sistemi di energia rinnovabile, comprese le turbine eoliche. Infatti, i motori a corrente alternata sono comunemente impiegati in varie applicazioni all'interno delle turbine eoliche grazie ai loro numerosi vantaggi. Ecco una spiegazione dettagliata:
1. Generatore: In un sistema di turbine eoliche, il motore a corrente alternata (CA) funge spesso da generatore. Ruotando, le pale della turbina eolica azionano il rotore del generatore, che converte l'energia meccanica del vento in energia elettrica. I generatori a corrente alternata (CA) sono comunemente utilizzati nelle turbine eoliche per la loro efficienza, affidabilità e compatibilità con le reti elettriche.
2. Controllo della velocità variabile: I motori a corrente alternata offrono il vantaggio del controllo della velocità variabile, fondamentale per le turbine eoliche. La velocità del vento è variabile e, per massimizzare la cattura di energia, la velocità del rotore deve essere regolata di conseguenza. I motori a corrente alternata, quando utilizzati come generatori, possono adattare la loro velocità di rotazione alle mutevoli condizioni del vento modificando la frequenza e la tensione del segnale elettrico in uscita.
3. Efficienza: I motori a corrente alternata sono noti per la loro elevata efficienza, un fattore importante nei sistemi di energia rinnovabile. Le turbine eoliche mirano a convertire la maggior quantità possibile di energia eolica in energia elettrica. I motori a corrente alternata, in particolare quelli progettati per un'elevata efficienza, possono contribuire a massimizzare l'efficienza di conversione energetica complessiva del sistema eolico.
4. Integrazione della rete: I motori a corrente alternata sono ideali per l'integrazione in rete nei sistemi di energia rinnovabile. L'uscita elettrica del generatore a corrente alternata può essere facilmente sincronizzata con la frequenza e la tensione di rete, consentendo una perfetta integrazione del sistema eolico con l'infrastruttura di rete elettrica esistente. Ciò facilita la distribuzione efficiente dell'elettricità generata ai consumatori.
5. Controllo e monitoraggio: I motori a corrente alternata offrono funzionalità avanzate di controllo e monitoraggio, essenziali per i sistemi di turbine eoliche. I parametri elettrici, come tensione, frequenza e potenza in uscita, possono essere facilmente monitorati e controllati nei generatori basati su motori a corrente alternata. Ciò consente il monitoraggio in tempo reale delle prestazioni della turbina eolica, il rilevamento dei guasti e l'ottimizzazione del processo di generazione di energia.
6. Disponibilità e standardizzazione: I motori a corrente alternata sono ampiamente disponibili in varie dimensioni e potenze, il che li rende facilmente accessibili per le applicazioni delle turbine eoliche. Sono inoltre ampiamente standardizzati, garantendo la compatibilità con altri componenti del sistema e facilitando le attività di manutenzione, riparazione e sostituzione.
Vale la pena notare che, sebbene i motori a corrente alternata siano comunemente utilizzati nelle turbine eoliche, esistono altri tipi di generatori e tecnologie di motori utilizzati in progetti specifici di turbine eoliche, come i generatori sincroni a magneti permanenti (PMSG) o i generatori a induzione a doppia alimentazione (DFIG). Queste alternative offrono i loro vantaggi e possono essere preferite in alcune configurazioni di turbine eoliche.
In sintesi, i motori a corrente alternata possono effettivamente essere utilizzati nei sistemi di energia rinnovabile, comprese le turbine eoliche. La loro efficienza, il controllo della velocità variabile, la capacità di integrazione in rete e le funzionalità di controllo avanzate li rendono una scelta adatta per convertire l'energia eolica in energia elettrica in modo affidabile ed efficiente.

Puoi spiegare il principio di funzionamento di base di un motore a corrente alternata?
Un motore a corrente alternata funziona basandosi sui principi dell'induzione elettromagnetica. Converte l'energia elettrica in energia meccanica attraverso l'interazione di campi magnetici. Il principio di funzionamento di base di un motore a corrente alternata prevede i seguenti passaggi:
- Il motore a corrente alternata è costituito da due componenti principali: lo statore e il rotore. Lo statore è la parte fissa del motore e contiene gli avvolgimenti dello statore. Il rotore è la parte rotante del motore ed è collegato a un albero.
- Quando agli avvolgimenti dello statore viene fornita corrente alternata (CA), si crea un campo magnetico variabile.
- Il campo magnetico variabile induce una tensione negli avvolgimenti del rotore, che sono barre conduttive o bobine in cortocircuito.
- La tensione indotta negli avvolgimenti del rotore crea un campo magnetico nel rotore.
- Il campo magnetico del rotore interagisce con il campo magnetico rotante dello statore, generando una forza di coppia.
- La forza di coppia fa ruotare il rotore, trasferendo energia meccanica all'albero collegato.
- La rotazione del rotore continua finché viene fornita alimentazione CA agli avvolgimenti dello statore.
Questo principio di funzionamento di base è applicabile a vari tipi di motori a corrente alternata, inclusi i motori a induzione e i motori sincroni. Tuttavia, la costruzione e il design specifici del motore possono variare a seconda del tipo e dell'applicazione prevista.


editor by CX 2023-11-27