Deskripsi Produk

BG 63 AC Motor 
Environmental Conditions -20ºC~50ºC
Insulation Clase B
Protection class IP40
Noise ≤70dB
Number of phases Single 
Saat ini AC&DC
Lifespan 1000-1500h

Electrical Specifications
Model RATED LOAD NO LOAD   STALL
 Voltase    Kekuatan  

  Kecepatan  

 Torque    Saat ini   Kecepatan    Saat ini   Torque   Saat ini 
V W putaran per menit N.m A putaran per menit A   N.m   A  
  BG AC6320  110 65 10000 0.062 0.9 17000 0.2  0.186 2.7
 BG AC6325 110 70 11000 0.06 0.97 18000 0.2  0.18 2.91
 BG AC6330 220 75 12000 0.06 0.52 20000 0.1  0.18 1.56
We can also customize products according to customer requirements.  

Established in 1994, HangZhou BG Motor Factory is a professional manufacturer of brushless DC motors, brushed DC motors, planetary gear motors, worm gear motors, Universal motors and AC motors. We have a plant area of 6000 square meters, multiple patent certificates, and we have the independent design and development capabilities and strong technical force, with an annual output of more than 1 million units. Since the beginning of its establishment, BG motor has focused on the overall solution of motors. We manufacture and design motors, provide professional customized services, respond quickly to customer needs, and actively help customers to solve problems. Our motor products are exported to 20 countries, including the United States, Germany, Italy, the United Kingdom, Poland, Slovenia, Switzerland, Sweden, Singapore, South Korea etc.
Our founder, Mr. Sun, has more than 40 years of experience in motor technology, and our other engineers also have more than 15 years of experience, and 60% of our staff have more than 10 years of experience, and we can assure you that the quality of our motors is top notch.
The products cover AGV, underwater robots, robots, sewing machine industry, automobiles, medical equipment, automatic doors, lifting equipment, industrial equipment and have a wide range of applications.
We strive for CHINAMFG in the quality of each product, and we are only a small and sophisticated manufacturer.
Our vision: Drive the world CHINAMFG and make life better!

Q:1.What kind of motors can you provide?

A:At present, we mainly produce brushless DC motors, brush DC motors, AC motors, Universal Motors; the power of the motor is less than 5000W, and the diameter of the motor is not more than 200mm;

Q:2.Can you send me a price list?

A:For all of our motors, they are customized based on different requirements like lifetime, noise,voltage,and shaft etc. The price also varies according to annual quantity. So it’s really difficult for us to provide a price list. If you can share your detailed requirements and annual quantity, we’ll see what offer we can provide.

Q:3.Can l get some samples?

A:It depends. If only a few samples for personal use or replacement, I am afraid it’ll be difficult for us to provide because all of our motors are custom made and no stock available if there are no further needs. If just sample testing before the official order and our MOQ,price and other terms are acceptable,we’d love to provide samples.

Q4:Can you provide OEM or ODM service?

A:Yes,OEM and ODM are both available, we have the professional R&D dept which can provide professional solutions for you.

Q5:Can l visit your factory before we place an order?

A:welcome to visit our factory,wear every pleased if we have the chance to know each other more.

Q:6.What’s the lead time for a regular order?

A:For orders, the standard lead time is 15-20 days and this time can be shorter or longer based on the different model,period and quantity.

Aplikasi: Universal
Kecepatan: 8000rpm-12000rpm
Jumlah Stator: Fase Tunggal
Fungsi: Penggerak
Perlindungan Casing: Tipe Tertutup
Jumlah Tiang: 2
Contoh:
US$ 0/Piece
1 Buah (Minimum Pemesanan)

|

Kustomisasi:
Tersedia

|

motor induksi

Apakah ada pertimbangan lingkungan yang terkait dengan penggunaan motor AC?

Ya, ada beberapa pertimbangan lingkungan yang terkait dengan penggunaan motor AC. Pertimbangan ini terutama berkaitan dengan konsumsi energi, emisi gas rumah kaca, dan pembuangan motor di akhir masa pakainya. Mari kita jelajahi pertimbangan lingkungan ini secara detail:

  • Efisiensi Energi: Motor AC dapat memiliki berbagai tingkat efisiensi energi, yang secara langsung memengaruhi dampak lingkungannya. Motor dengan efisiensi lebih tinggi mengubah persentase energi listrik yang lebih besar menjadi kerja mekanik yang bermanfaat, sehingga mengurangi konsumsi energi. Dengan memilih dan menggunakan motor AC efisiensi tinggi, penggunaan energi dapat diminimalkan, yang menyebabkan emisi gas rumah kaca lebih rendah dan mengurangi ketergantungan pada bahan bakar fosil untuk pembangkit listrik.
  • Emisi Gas Rumah Kaca: Listrik yang dikonsumsi oleh motor AC sering kali dihasilkan oleh pembangkit listrik yang membakar bahan bakar fosil, seperti batu bara, gas alam, atau minyak. Pembangkitan listrik dari bahan bakar fosil ini melepaskan gas rumah kaca, yang berkontribusi terhadap perubahan iklim. Dengan menggunakan motor hemat energi dan mengoptimalkan sistem motor, bisnis dan individu dapat mengurangi permintaan listrik mereka, sehingga mengurangi emisi gas rumah kaca dan jejak karbon.
  • Pembuangan dan Daur Ulang Motor: Motor AC mengandung berbagai material, termasuk logam, plastik, dan komponen listrik. Di akhir siklus hidupnya, pembuangan atau daur ulang yang tepat sangat penting untuk meminimalkan dampak lingkungan. Beberapa komponen, seperti kumparan tembaga dan casing baja, dapat didaur ulang, mengurangi kebutuhan akan bahan baku baru dan proses manufaktur yang intensif energi. Sangat penting untuk mengikuti peraturan dan pedoman setempat untuk pembuangan dan daur ulang motor guna mencegah pencemaran lingkungan dan mendorong konservasi sumber daya.
  • Manufaktur dan Produksi: Proses manufaktur dan produksi yang terkait dengan motor AC dapat memiliki implikasi lingkungan. Ekstraksi dan pengolahan bahan baku, seperti logam dan plastik, dapat mengakibatkan kerusakan habitat, konsumsi energi, dan emisi gas rumah kaca. Selain itu, proses manufaktur itu sendiri dapat menghasilkan limbah dan polutan. Produsen motor dapat mengurangi dampak lingkungan ini dengan mengadopsi praktik berkelanjutan, menggunakan bahan daur ulang, mengurangi produksi limbah, dan menerapkan metode produksi yang hemat energi.
  • Penilaian Siklus Hidup: Melakukan penilaian siklus hidup (LCA) pada motor AC dapat memberikan pandangan holistik tentang dampak lingkungannya. LCA mempertimbangkan aspek lingkungan yang terkait dengan seluruh siklus hidup motor, termasuk ekstraksi bahan baku, manufaktur, transportasi, penggunaan, dan pembuangan atau daur ulang di akhir masa pakainya. Dengan menganalisis berbagai tahapan siklus hidup motor, para pemangku kepentingan dapat mengidentifikasi peluang untuk perbaikan, seperti mengoptimalkan efisiensi energi, mengurangi emisi, dan menerapkan praktik berkelanjutan.

Untuk mengatasi pertimbangan lingkungan ini, pemerintah, organisasi, dan badan standar industri telah mengembangkan peraturan dan pedoman untuk mempromosikan efisiensi energi dan mengurangi dampak lingkungan dari motor AC. Ini termasuk standar efisiensi, program pelabelan, dan insentif untuk penggunaan motor efisiensi tinggi. Selain itu, inisiatif yang mempromosikan optimasi sistem motor, seperti penentuan ukuran motor yang tepat, perawatan, dan kontrol, dapat lebih meningkatkan efisiensi energi dan meminimalkan dampak lingkungan.

Singkatnya, pertimbangan lingkungan yang terkait dengan penggunaan motor AC meliputi efisiensi energi, emisi gas rumah kaca, pembuangan dan daur ulang motor, proses manufaktur, dan penilaian siklus hidup. Dengan memprioritaskan efisiensi energi, pembuangan yang tepat, daur ulang, dan praktik manufaktur berkelanjutan, dampak lingkungan dari motor AC dapat diminimalkan, sehingga berkontribusi pada pendekatan yang lebih berkelanjutan dan ramah lingkungan terhadap penggunaan motor.

motor induksi

What are the common signs of AC motor failure, and how can they be addressed?

AC motor failure can lead to disruptions in various industrial and commercial applications. Recognizing the common signs of motor failure is crucial for timely intervention and preventing further damage. Here are some typical signs of AC motor failure and potential ways to address them:

  • Excessive Heat: Excessive heat is a common indicator of motor failure. If a motor feels excessively hot to the touch or emits a burning smell, it could signify issues such as overloaded windings, poor ventilation, or bearing problems. To address this, first, ensure that the motor is properly sized for the application. Check for obstructions around the motor that may be impeding airflow and causing overheating. Clean or replace dirty or clogged ventilation systems. If the issue persists, consult a qualified technician to inspect the motor windings and bearings and make any necessary repairs or replacements.
  • Abnormal Noise or Vibration: Unusual noises or vibrations coming from an AC motor can indicate various problems. Excessive noise may be caused by loose or damaged components, misaligned shafts, or worn bearings. Excessive vibration can result from imbalanced rotors, misalignment, or worn-out motor parts. Addressing these issues involves inspecting and adjusting motor components, ensuring proper alignment, and replacing damaged or worn-out parts. Regular maintenance, including lubrication of bearings, can help prevent excessive noise and vibration and extend the motor’s lifespan.
  • Intermittent Operation: Intermittent motor operation, where the motor starts and stops unexpectedly or fails to start consistently, can be a sign of motor failure. This can be caused by issues such as faulty wiring connections, damaged or worn motor brushes, or problems with the motor’s control circuitry. Check for loose or damaged wiring connections and make any necessary repairs. Inspect and replace worn or damaged motor brushes. If the motor still exhibits intermittent operation, it may require professional troubleshooting and repair by a qualified technician.
  • Overheating or Tripping of Circuit Breakers: If an AC motor consistently causes circuit breakers to trip or if it repeatedly overheats, it indicates a problem that needs attention. Possible causes include high starting currents, excessive loads, or insulation breakdown. Verify that the motor is not overloaded and that the load is within the motor’s rated capacity. Check the motor’s insulation resistance to ensure it is within acceptable limits. If these measures do not resolve the issue, consult a professional to assess the motor and its electrical connections for any faults or insulation breakdown that may require repair or replacement.
  • Decreased Performance or Efficiency: A decline in motor performance or efficiency can be an indication of impending failure. This may manifest as reduced speed, decreased torque, increased energy consumption, or inadequate power output. Factors contributing to decreased performance can include worn bearings, damaged windings, or deteriorated insulation. Regular maintenance, including lubrication and cleaning, can help prevent these issues. If performance continues to decline, consult a qualified technician to inspect the motor and perform any necessary repairs or replacements.
  • Inoperative Motor: If an AC motor fails to operate entirely, there may be an issue with the power supply, control circuitry, or internal motor components. Check the power supply and connections for any faults or interruptions. Inspect control circuitry, such as motor starters or contactors, for any damage or malfunction. If no external faults are found, it may be necessary to dismantle the motor and inspect internal components, such as windings or brushes, for any faults or failures that require repair or replacement.

It’s important to note that motor failure causes can vary depending on factors such as motor type, operating conditions, and maintenance practices. Regular motor maintenance, including inspections, lubrication, and cleaning, is essential for early detection of potential failure signs and for addressing issues promptly. When in doubt, it is advisable to consult a qualified electrician, motor technician, or manufacturer’s guidelines for appropriate troubleshooting and repair procedures specific to the motor model and application.

motor induksi

Apa saja komponen utama dari motor AC, dan bagaimana komponen-komponen tersebut berkontribusi terhadap pengoperasiannya?

Motor AC terdiri dari beberapa komponen utama yang bekerja bersama untuk memfasilitasi pengoperasiannya. Komponen-komponen ini meliputi:

  1. Stator: Stator adalah bagian stasioner dari motor AC. Biasanya terbuat dari inti berlapis yang menyediakan jalur bagi fluks magnetik. Stator berisi gulungan stator, yaitu kumparan kawat yang dililitkan di sekitar inti stator. Gulungan stator dihubungkan ke sumber daya AC dan menghasilkan medan magnet berputar ketika diberi energi. Medan magnet berputar merupakan elemen penting dalam menghasilkan torsi yang dibutuhkan untuk pengoperasian motor.
  2. Rotor: Rotor adalah bagian yang berputar dari motor AC. Rotor terletak di dalam stator dan terhubung ke poros. Rotor dapat memiliki desain yang berbeda tergantung pada jenis motor AC. Pada motor induksi, rotor tidak memiliki koneksi listrik. Sebagai gantinya, rotor berisi batang atau kumparan konduktif yang dihubung pendek. Medan magnet berputar dari stator menginduksi arus pada konduktor rotor yang dihubung pendek, menciptakan medan magnet yang berinteraksi dengan medan stator dan menghasilkan torsi, menyebabkan rotor berputar. Pada motor sinkron, rotor berisi elektromagnet yang dimagnetisasi oleh arus searah, memungkinkan rotor untuk mengunci pada medan magnet berputar dari stator dan berputar dengan kecepatan yang sama.
  3. Bantalan: Bantalan digunakan untuk menopang dan memfasilitasi putaran poros rotor yang lancar. Bantalan mengurangi gesekan dan memungkinkan rotor berputar bebas di dalam motor. Bantalan biasanya terletak di kedua ujung poros motor dan dirancang untuk menahan gaya aksial dan radial yang dihasilkan selama pengoperasian.
  4. Bel Akhir: Penutup ujung, juga dikenal sebagai penutup ujung atau braket ujung, membungkus rakitan stator dan rotor motor. Penutup ini memberikan dukungan mekanis dan perlindungan untuk komponen internal motor. Penutup ujung biasanya terbuat dari logam dan dirancang untuk menyediakan wadah bagi bantalan dan mengamankan motor ke struktur pemasangannya.
  5. Kipas atau Sistem Pendingin: Motor AC sering menghasilkan panas selama beroperasi. Untuk mencegah panas berlebih dan memastikan fungsi yang tepat, motor AC dilengkapi dengan kipas atau sistem pendingin. Sistem ini membantu menghilangkan panas dengan mensirkulasikan udara atau mengarahkan aliran udara ke komponen motor, termasuk kumparan stator dan rotor. Pendinginan yang efektif sangat penting untuk menjaga efisiensi motor dan memperpanjang umur pakainya.
  6. Kotak Terminal atau Kotak Koneksi: Kotak terminal adalah wadah yang terletak di bagian luar motor yang menyediakan akses ke sambungan listrik motor. Di dalamnya terdapat terminal atau titik sambungan tempat kabel eksternal dapat dihubungkan untuk memasok daya ke motor. Kotak terminal memastikan sambungan motor yang aman dan terjamin ke sistem kelistrikan.
  7. Komponen Tambahan: Tergantung pada desain dan aplikasi spesifiknya, motor AC dapat mencakup komponen tambahan seperti kapasitor, sakelar sentrifugal, sikat (pada jenis motor AC tertentu), dan perangkat kontrol lainnya. Komponen-komponen ini digunakan untuk berbagai tujuan, seperti meningkatkan kinerja motor, memberikan bantuan saat memulai, atau mengaktifkan fitur kontrol tertentu.

Masing-masing komponen ini memainkan peran penting dalam pengoperasian motor AC. Stator dan rotor adalah komponen utama yang bertanggung jawab untuk menghasilkan medan magnet berputar dan mengubah energi listrik menjadi gerakan mekanis. Bantalan memastikan putaran poros rotor yang lancar, sementara penutup ujung memberikan dukungan struktural dan perlindungan. Kipas atau sistem pendingin membantu menjaga suhu operasi optimal, dan kotak terminal memungkinkan koneksi listrik yang tepat. Komponen tambahan ditambahkan seperlunya untuk meningkatkan kinerja motor dan memungkinkan fungsi tertentu.

China Good quality for Coffee Machines Juicer Medical Centrifuge Power Tools 63mm 65W 10000rpm High Torque 110V AC Universal Motor   wholesaler China Good quality for Coffee Machines Juicer Medical Centrifuge Power Tools 63mm 65W 10000rpm High Torque 110V AC Universal Motor   wholesaler
editor by CX 2023-11-27