Around 19kg 24000rpm High Speed Synchronous Reluctance AC Motor

Around 19kg 24000rpm High Speed Synchronous Reluctance AC Motor

Close to 19KG 24000RPM Substantial Pace Synchronous Reluctance AC Motor

Item Characteristic
1.Ideal for the 24000rpm substantial velocity
two.Reserve a massive margin of stability
3.Higher electricity & higher torque
4.Large performance
five.Small measurement
6.Minimal sounds low vibration
seven.The autonomous patented cooling framework

Requirements
Product variety: SRPM112H4W22
Voltage: 380V AC
Rated Electricity: 22KW
Charge Torque : eight.8N.m
Rated speed: 24000rpm
Efficiency: 94.three%
Isolation: H/F
Drinking water/dust Proof: IP54
Pole Quantity: 4
N Excess weight: all around 19KG
Cooling Method: Drinking water

Application
High-pace Compressors,Supporters,Pumps

Other Types you will be interested in:

Motor variety Voltage
(V AC)
Rated power
(kW)
Rated torque (N.m) Rated velocity
(rpm)
Efficiency
(%)
Responsibility type  Insulation Ingress security Pole Amount Weight
(kg)
Cooling Approach situation sign
SRPM160H4XO15 380 fifteen 5.ninety six 24000 96.five S1 H/F IP67 4 12 Oil  Resolver
SRPM160H4XO75 380 seventy five 35.8 24000 ninety six.5 S1 H/F IP67 4 44 Oil  Resolver
SRPM160H4XO90 380 ninety forty three 24000 ninety six.5 S1 H/F IP67 4 48 Oil  Resolver
SRPM205H4XO110 380 110 52.five 24000 ninety six.5 S1 H/F IP67 four seventy six Oil  Resolver
SRPM205H4XO160 380 160 seventy six.four 24000 96.5 S1 H/F IP67 four 86 Oil  Resolver
SRPM205H4XO200 380 200 ninety five.5 24000 ninety six.5 S1 H/F IP67 four 95 Oil  Resolver

FAQ
1. Can performanent magnet synchronous motor be employed as generator? 

No. Permanent magnet synchronous motor is definitely various from generator. It is only ac motor that outputs speed and torque to push electric powered gadgets, but not power provide. 
 
2. Why can not immediately use a few stage ac source voltage to commence long lasting magnet synchronous motor? 
Becuase rotor is with big innertia, and magetic data files spins so rapidly that static rotor has no way to spin with magetic filed. 
 
three. Any unique complex ask for on this motor’s VFD driver? And Do you have these kinds of driver? 
Permanent magnet synchronous motor’s driver need to be vector control VFD with special interior application, these kinds of as Siemens 6SE70 collection, Yakawa CR5 series, ABB ACS800 series, Mitsubishi A740 series, B&R P84 and P74 sequence, and many others.. Yes, our MH300 sequence VFD matches with this motor. 
 
four. Is there any protecting steps to defend long term magnet rotor from failure? 
Yes, each everlasting magnet rotor passes corrossion resistance, regularity, large temperature demagnetization take a look at, linear demagnetization check, and so on. Its demagnetization index is inside 2%. But if doing work surroundings is critical oxiditive corrosion, kindly recommend for higher safety degree. 
 
5. Where is this long lasting magnet synchronous motor normally utilized to? 
This long term magnet synchronous motor is normally utilised to variable frequency pace predicament.

 

Around 19kg 24000rpm High Speed Synchronous Reluctance AC Motor