Causes of motor failures and troubleshooting methods one

author:xiaoE date:2021-07-06 14: 01

  XNUMX. The motor can't rotate after power on, but there is no abnormal noise, no strange smell and smoke

  1. The cause of the failure:

  The power is not connected (at least two phases are not connected)

  Fuse blown (at least two phase blown)

  The overcurrent relay is adjusted too small

  Control device wiring error

  2. Troubleshooting

  Check whether there are breakpoints at the power circuit switch, fuse, and junction box, and repair it.

  Check the fuse type, the cause of the fuse, and replace it with a new fuse

  Adjust the setting value of the relay to cooperate with the motor

  Correct the wiring

  XNUMX. The motor does not rotate after power-on, and then the fuse is blown

  1. The cause of the failure

  One-phase power supply is missing, or the fixed and dry coil is connected oppositely

  Short circuit between stator windings

  Stator winding is grounded

  Stator winding wiring error

  Fuse section is too small

  The power cord is shorted or grounded

  2. Troubleshooting

  Check whether one phase of the knife switch is not closed, or one phase of the power circuit is disconnected, and eliminate the reverse connection fault

  Detect the short-circuit point and repair it

  Eliminate grounding

  Detect misconnections and correct them

  Replace the fuse

  Eliminate ground points

  XNUMX. The motor does not rotate after power-on, and there is a buzzing sound

  1. The cause of the failure:

  There is an open circuit in the stator and rotor windings (one-phase disconnection) or one-phase power loss

  The lead wire of the winding is disconnected from the beginning and the end is wrong or the winding is connected reverse

  The power circuit contacts are loose and the contact resistance is large

  The motor load is too large or the rotor is stuck

  Power supply is low

  The small motor assembly is too tight or the grease in the bearing is too hard

  Bearing stuck

  2. Troubleshooting

  Find the breakpoint and fix it

  Check the polarity of the winding; determine whether the end of the winding is correct

  Tighten the loose wiring screws, use a multimeter to judge whether each connector is falsely connected, and repair it

  Reduce load or detect and eliminate mechanical failures

  Check whether the connection method is wrong, whether the voltage drop is too large due to the power wire is too thin, and correct it

  Reassemble to make it flexible and replace qualified grease

  Repair the bearing

About Us      |       Products      |       News      |       Culture      |       Contact Us      |